Chris Peach

Chris Peach

Auto-generated profile, based on publicly available information

Chris Peach

Manchester Shoulder and Elbow Unit Manchester University NHS Foundation Trust, Wythenshawe Hospital Manchester UK

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in The Lancet
Verified
Journal Article
Open access
DBDavid Beard
David Beard
JRJonathan L Rees
Jonathan L Rees
JCJonathan Cook
Jonathan Cook
IRInes Rombach
Ines Rombach
CCCushla Cooper
Cushla Cooper
DWDavid Woods
David Woods
Arthroscopic sub-acromial decompression (decompressing the sub-acromial space by removing bone spurs and soft tissue arthroscopically) is a common surgery for subacromial shoulder pain, but its effectiveness is uncertain. We did a study to assess its effectiveness and to investigate the mechanism for surgical decompression. We did a multicentre, randomised, pragmatic, parallel group, placebo-controlled, three-group trial at 32 hospitals in the UK with 51 surgeons. Participants were patients who had subacromial pain for at least 3 months with intact rotator cuff tendons, were eligible for arthroscopic surgery, and had previously completed a non-operative management programme that included exercise therapy and at least one steroid injection. Exclusion criteria included a full-thickness torn rotator cuff. We randomly assigned participants (1:1:1) to arthroscopic subacromial decompression, investigational arthroscopy only, or no treatment (attendance of one reassessment appointment with a specialist shoulder clinician 3 months after study entry, but no intervention). Arthroscopy only was a placebo as the essential surgical element (bone and soft tissue removal) was omitted. We did the randomisation with a computer-generated minimisation system. In the surgical intervention groups, patients were not told which type of surgery they were receiving (to ensure masking). Patients were followed up at 6 months and 1 year after randomisation; surgeons coordinated their waiting lists to schedule surgeries as close as possible to randomisation. The primary outcome was the Oxford Shoulder Score (0 [worst] to 48 [best]) at 6 months, analysed by intention to treat. The sample size calculation was based upon a target difference of 4·5 points (SD 9·0). This trial has been registered at ClinicalTrials.gov, number NCT01623011. Between Sept 14, 2012, and June 16, 2015, we randomly assigned 313 patients to treatment groups (106 to decompression surgery, 103 to arthroscopy only, and 104 to no treatment). 24 [23%], 43 [42%], and 12 [12%] of the decompression, arthroscopy only, and no treatment groups, respectively, did not receive their assigned treatment by 6 months. At 6 months, data for the Oxford Shoulder Score were available for 90 patients assigned to decompression, 94 to arthroscopy, and 90 to no treatment. Mean Oxford Shoulder Score did not differ between the two surgical groups at 6 months (decompression mean 32·7 points [SD 11·6] vs arthroscopy mean 34·2 points [9·2]; mean difference -1·3 points (95% CI -3·9 to 1·3, p=0·3141). Both surgical groups showed a small benefit over no treatment (mean 29·4 points [SD 11·9], mean difference vs decompression 2·8 points [95% CI 0·5-5·2], p=0·0186; mean difference vs arthroscopy 4·2 [1·8-6·6], p=0·0014) but these differences were not clinically important. There were six study-related complications that were all frozen shoulders (in two patients in each group). Surgical groups had better outcomes for shoulder pain and function compared with no treatment but this difference was not clinically important. Additionally, surgical decompression appeared to offer no extra benefit over arthroscopy only. The difference between the surgical groups and no treatment might be the result of, for instance, a placebo effect or postoperative physiotherapy. The findings question the value of this operation for these indications, and this should be communicated to patients during the shared treatment decision-making process. Arthritis Research UK, the National Institute for Health Research Biomedical Research Centre, and the Royal College of Surgeons (England).

1 April 2005 in Trends in Molecular Medicine
Verified
Journal Article
Closed access
CPChris A. Peach
Chris A. Peach
ACAndrew J. Carr
Andrew J. Carr
JLJohn Loughlin
John Loughlin

3 April 2017 in Virtual and Physical Prototyping
Verified
Journal Article
Closed access
AAAbdulsalam Abdulaziz Al-Tamimi
Abdulsalam Abdulaziz Al-Tamimi
PFPaulo Rui Fernandes
Paulo Rui Fernandes
CPChris Peach
Chris Peach
Glen CooperGlen Cooper
Glen Cooper
CDCarl Diver
Carl Diver
Paulo BartoloPaulo Bartolo
Paulo Bartolo
Fixation devices are commonly used for bone fracture treatments. These implants are made of biocompatible materials such as stainless steel, cobalt, titanium and its alloys (e.g. CoCrMo and Ti-6Al-4V). However, metallic medical implants present higher stiffness compared to bone, contributing to the stress shielding phenomena compromising bone integrity. This paper explores the use of topology optimization to create novel bone fixation designs with reduced material volumes. Results show that for certain levels of volume reductions, which depends on the load condition, it is possible to obtain designs that minimise the stress shielding phenomena.

1 January 2017 in Procedia CIRP
Verified
Journal Article
Open access
AAAbdulsalam A. Al-Tamimi
Abdulsalam A. Al-Tamimi
CPChris Peach
Chris Peach
PFPaulo Rui Fernandes
Paulo Rui Fernandes
ACAkos Cseke
Akos Cseke
Paulo BartoloPaulo Bartolo
Paulo Bartolo

27 April 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
AJAli Jabran
Ali Jabran
CPChris Peach
Chris Peach
LRLei Ren
Lei Ren
Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates’ mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two- and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load–displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs’ mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.

22 March 2016 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MZManxu Zheng
Manxu Zheng
ZZZhenmin Zou
Zhenmin Zou
Paulo BartoloPaulo Bartolo
Paulo Bartolo
CPChris Peach
Chris Peach
LRLei Ren
Lei Ren
Summary: The human shoulder is a complicated musculoskeletal structure and is a perfect compromise between mobility and stability. The objective of this paper is to provide a thorough review of previous finite element (FE) studies in biomechanics of the human shoulder complex. Those FE studies to investigate shoulder biomechanics have been reviewed according to the physiological and clinical problems addressed: glenohumeral joint stability, rotator cuff tears, joint capsular and labral defects and shoulder arthroplasty. The major findings, limitations, potential clinical applications and modelling techniques of those FE studies are critically discussed. The main challenges faced in order to accurately represent the realistic physiological functions of the shoulder mechanism in FE simulations involve (1) subject‐specific representation of the anisotropic nonhomogeneous material properties of the shoulder tissues in both healthy and pathological conditions; (2) definition of boundary and loading conditions based on individualised physiological data; (3) more comprehensive modelling describing the whole shoulder complex including appropriate three‐dimensional (3D) representation of all major shoulder hard tissues and soft tissues and their delicate interactions; (4) rigorous in vivo experimental validation of FE simulation results. Fully validated shoulder FE models would greatly enhance our understanding of the aetiology of shoulder disorders, and hence facilitate the development of more efficient clinical diagnoses, non‐surgical and surgical treatments, as well as shoulder orthotics and prosthetics. © 2016 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.