Eduardo Rausell

Eduardo Rausell

Auto-generated profile, based on publicly available information

Eduardo Rausell

CIEMAT

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
JFJuan Dolado Fernández
Juan Dolado Fernández
JEJoaquín Eloy-Garcia
Joaquín Eloy-Garcia
ENEduardo Rausell Navarro
Eduardo Rausell Navarro
Santiago ArnaltesSantiago Arnaltes
Santiago Arnaltes
JAJose Luis Rodriguez Amenedo
Jose Luis Rodriguez Amenedo
In recent years, the increasing integration of renewable energy sources into power systems has led to significant changes in grid operation. Power electronic converters are primarily used to connect these power plants to the electrical system and, as key components in modern power systems, grid-forming (GFM) converters have emerged to provide the ability to autonomously establish and maintain system stability without the need for synchronous generators (SGs). The current contribution during faults is one of the main differences between SGs and power converters, which can affect protective systems. The most recent grid codes require a fast current injection in the event of a fault. This article presents a low-voltage ride-through control strategy for GFM converters based on virtual-flux orientation according to the European Commission Regulation (EU) 2016/631 and the Spanish Technical Supervision Standard requirements. For the validation of this control algorithm, a hardware test bed has been implemented consisting of two dc voltage sources emulating a photovoltaic plant feeding the dc bus of a voltage source converter and, finally, a grid emulator where the different voltage faults have been programmed.

30 July 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
EREduardo Rausell
Eduardo Rausell
Santiago ArnaltesSantiago Arnaltes
Santiago Arnaltes
JRJosé Luis Rodríguez
José Luis Rodríguez
MLMarcos Lafoz
Marcos Lafoz
GNGustavo Navarro
Gustavo Navarro

4 July 2025 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
EREduardo Rausell
Eduardo Rausell
Santiago ArnaltesSantiago Arnaltes
Santiago Arnaltes
AAAndrés Peña Asensio
Andrés Peña Asensio
JRJosé Luis Rodriguez
José Luis Rodriguez
MLMarcos Lafoz
Marcos Lafoz
GNGustavo Navarro
Gustavo Navarro

7 January 2025 in IEEE Access
Verified
Journal Article
Open access
JFJuan Dolado Fernández
Juan Dolado Fernández
ENEduardo Rausell Navarro
Eduardo Rausell Navarro
JAJose Luis Rodriguez Amenedo
Jose Luis Rodriguez Amenedo
JEJoaquín Eloy-Garcia
Joaquín Eloy-Garcia
Santiago ArnaltesSantiago Arnaltes
Santiago Arnaltes
The electric power system is undergoing a significant transition. Renewable energy generation capacity has increased, leading to the displacement of synchronous generators (SG) and a growing concern about grid stability due to the decrease of rotating inertial energy. Grid-forming (GFM) converters have become a technological solution to this challenge, as they are capable of operating in low strengh system conditions and helping to stabilize the voltage and frequency of the grid. In this paper, a novel control scheme for GFM converters is validated in a commercial converter according to the National Grid ESO, called National Energy System Operator (NESO) since October 2024. The control scheme uses the flux vector as a simple and effective method for limiting the active and reactive currents without internal current loops. For this purpose, a hardware test bed has been implemented consisting of two DC sources emulating a photovoltaic (PV) plant which feed the DC bus a voltage source converter (VSC), a grid emulator which allows to generate the desired disturbances in the grid to evaluate the converter’s response and a three-phase load. The results obtained have validated that these GFM converters based on the flux vector are capable of synchronizing with the grid, responding against frequency disturbances like phase jumps or faults in the grid and operating in islanded mode. In addition, the innovative method used to limit the active and reactive current has also been tested, comparing its performance with that of a conventional GFM scheme, showing an improvement in the response stability.

17 February 2026 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
Jorge NájeraJorge Nájera
Jorge Nájera
JRJaime Rodriguez
Jaime Rodriguez
EFEnrique Alcala Fazio
Enrique Alcala Fazio
EREduardo Rausell
Eduardo Rausell
JOSE MARIA LOPEZ MARTINEZJOSE MARIA LOPEZ MARTINEZ
JOSE MARIA LOPEZ MARTINEZ
Dimensioning the energy storage systems for a heavy-duty fuel cell hybrid electric vehicle is not straightforward. This study proposes a methodology to address this challenge, aiming to maximize efficiency while mitigating the aging effects on the energy storage systems. Various configurations of storage system ratios have been analyzed using the concept of hybridization percentage, which represents the ratio between the supercapacitor weight and the total weight of the energy storage elements. Simulations were conducted using models developed in AVL Cruise MTM. A case study is included to test the methodology, incorporating commercial components, a standard driving cycle, and a rule-based energy management strategy. The conclusions of this application example illustrate the types of results that can be obtained by using this hybrid energy storage system sizing methodology. Findings for this case study suggest that for cycles lacking extreme power peaks, non-hybridized configurations can be the optimal solution, as the battery size reduction outweighs the benefits of hybridization in terms of efficiency, achieving 76.08% without supercapacitors compared to 65.7% with a high hybridization grade of 32.4%, and overall cost. However, sensitivity analysis reveals that if the optimization weights are adjusted to prioritize aging over efficiency, the optimal configuration shifts to a 6.48% hybridization grade at a 0.3C threshold.

8 September 2025 in Proceedings of the European Wave and Tidal Energy Conference
Verified
Journal Article
Closed access
PDF file
MBMarcos Blanco
Marcos Blanco
Jorge NájeraJorge Nájera
Jorge Nájera
Gustavo NavarroGustavo Navarro
Gustavo Navarro
MLMarcos Lafoz
Marcos Lafoz
EREduardo Rausell
Eduardo Rausell
JMJavier Munilla
Javier Munilla
The development of Power Take-Off (PTO) systems is crucial for the progress of wave energy technologies. Among the different PTO concepts, direct-drive systems based on linear electrical generators stand out due to their simplicity, robustness, and efficiency, as they minimize energy transformations. Despite their advantages, linear electrical generators face significant challenges, particularly in terms of force density and reactive power capability. These limitations are most evident at low operational speeds, where high currents are required to generate adequate forces, leading to significant Joule losses. Furthermore, the management of reactive power for implementing advanced control strategies, such as reactive or pseudo-optimal wave energy extraction, is hindered by constant energy dissipation. This is particularly problematic at null or low velocities, where Joule losses persist regardless of speed, limiting the use of reactive power Superconducting technology has emerged as a promising solution to these challenges by significantly improving force density while reducing Joule losses. However, the cryogenic systems required for maintaining superconducting conditions impose strict constraints, as all conductor losses, including AC losses associated with oscillating currents, must be minimized. In this context, the paper describes a novel concept for a linear generator based on switched reluctance and superconducting coils, protected under a patented design. To address the issue of AC losses in superconducting cables, we introduce an innovative control strategy for the electronic converter associated with the generator. This strategy is designed to minimize current ripple in the generator phases, reducing oscillation frequencies and, consequently, AC losses. The proposed approach employs a single-pulse switching strategy, where each phase of the converter is activated and deactivated without intermediate semiconductor switching. This eliminates additional ripple in the phase currents. To regulate the force amplitude, the voltage of the DC link connected to the converter is controlled, enabling precise force modulation. The paper provides a comprehensive description of the switching strategy and evaluates its performance under oscillatory motion conditions typical of wave energy converters (WECs). A detailed comparison with conventional strategies demonstrates the proposed approach's potential to enhance generator efficiency, reduce losses, and improve overall performance. This work highlights the feasibility of integrating superconducting direct-drive PTO systems into WECs, paving the way for more efficient and reliable wave energy technologies.