The nonuniform superconducting current distribution in a REBCO coated conductor, including a varying-field-induced screening current, is responsible for a significant magnetization effect that not only degrades the field quality of REBCO magnets, but introduces risks of overstressing the conductor. This paper presents our experimental and simulation studies on the screening current effect on an 800 MHz (18.8 T) REBCO insert (H800) that together with a 500 MHz LTS nuclear magnetic resonance (NMR) magnet (L500) constitutes the MIT 1.3 GHz LTS/HTS NMR magnet (1.3 G). To develop our simulation model, which was subsequently validated by a good agreement between simulation and experiment, we chose H800, Coil 1 of the 3-coil assembly operated alone and the entire H800, for the sources of experimental data, specifically their remnant fields after current discharge and diminished axial fields during operation. Armed with this valid model, we examined in detail the negative effects of screening current on H800, an important 1.3 G component. Our simulation indicates that the screening current, nonuniformly distributed in the REBCO conductor, not only deteriorates H800 field, both strength and homogeneity, thus that of 1.3 G, but may overstress the REBCO conductor.
25 February 2019 in IEEE Transactions on Applied Superconductivity
We present assembly and test results of a 3-nested-coil 800-MHz (18.8 T) REBCO insert (H800) for the MIT 1.3 GHz LTS/HTS NMR magnet currently under completion. Each of the three H800 coils is a stack of no-insulation (NI) REBCO double-pancake coils (DPs). The innermost 8.7-T Coil 1 (26 DPs) was completed by mid-2016; the middle 5.6-T Coil 2 (32 DPs) was completed in mid-2017; while the outermost 4.5-T Coil 3 (38 DPs) was completed in early 2018. Coils 1, 2, and 3 were assembled together in early 2018 as a 3-nested-coil, the H800, and tested, first in liquid nitrogen to a power supply current of 20 A, followed by testing in liquid helium to a power supply current of 251.3 A, the H800's design operating current. After roughly five minutes settling time at 251.3 A, the H800 quenched. In this paper, we examine probable sources of quench initiation and simulate ensuing quench behavior. Remedial efforts to minimize the tendency toward quenching in the H800 are presented and discussed.
18 February 2020 in IEEE Transactions on Applied Superconductivity
Screening currents in REBCO conductors, induced by time-varying magnetic fields, not only affect the field quality of HTS coils but also cause strain gradients along REBCO tape width that may overstress REBCO conductors used in NMR and other high-field magnets. In this paper, we present results of an experimental and analytical study on screening-current-induced strain gradients, performed with small REBCO pancake coils. Because we believe that screening current effect is reduced in multifilament conductor, we have studied 2 test coils, φ150 mm, one wound with monofilament and the other with 3-striate/4-filament REBCO tapes. A 5-T/ 300-mm room-temperature bore magnet was used not only to excite a strong screening current but also apply the nonuniform Lorentz force to each coil at 4.2 K. Our experiment and analysis have quantitatively demonstrated that we can effectively suppress the screening-current effect on strain gradient, not surprisingly, by using striated multifilament REBCO conductor.
4 March 2021 in IEEE Transactions on Applied Superconductivity
We present a design overview of the MIT 1.3-GHz LTS/HTS NMR magnet (1.3G) with a newly designed 835-MHz REBCO insert (H835) as a replacement for the 800-MHz REBCO insert (H800) that was damaged when it quenched during operation in 2018. The new H835 is designed to contribute 19.6 T in a background field of 10.93 T by an LTS NMR magnet that normally rated at 11.74 T (500 MHz): combined, 1.3G generates a total field of 30.53 T corresponding to a proton resonance frequency of 1.3 GHz. H835 is designed to operate stably while meeting 1.3G design constraints. We have also designed H835 to protect it from permanent damage in an improbable event like a quench. Key design features are: 1) a single-coil formation, composed of 38 stacked metal-co-wound no-insulation and 2 stacked no-insulation double-pancake coils, all with mechanically improved cross-over sections; 2) enhanced thermal stability; and 3) reduced current margin with a detect-and-heat method. This paper includes: 1) electromagnetic and mechanical design of H835; 2) cryogenics overview; 3) quench protection strategy; and 3) discussion on the next steps to successfully complete 1.3G.
31 August 2022 in Superconductor Science and Technology
A compact benchtop high-field REBCO nuclear magnetic resonance is one of the most promising high-temperature superconductor applications. An all-REBCO, conduction-cooled magnet is a very attractive design option for demonstrating the unique potential of REBCO for forefront magnets. In this research, we have successfully constructed and tested a prototype all-REBCO, conduction-cooled, 23.5 T magnet operating at 10 K. We have applied the concept of an extreme no-insulation winding technique, coupled with a solder-shunting procedure to improve magnet performance. We have also used a temperature-controlled charging sequence to reduce the screening current. The magnet was energized to 23.6 T at 14 K; it was further operated to 25 T at 10 K for nearly 60 h.
22 February 2019 in IEEE Transactions on Applied Superconductivity
We present post-quench analyses of the MIT 800-MHz REBCO insert magnet (H800), unexpectedly quenched during operation in March 2018, and design study of a new 800-MHz HTS insert (H800N). The as-wound H800 was supposed to contribute 18.7 T and, with an LTS background magnet (L500), produce 30.5 T corresponding to a proton resonance frequency of 1.3 GHz. The H800 was operated at 4.2 K in liquid helium and, about 5 min after the power supply reached a target operating current of 251.3 A, it experienced a quench. Because the damage in the H800 was more widespread than it first appeared, we decided to design and build a new insert magnet, H800N. In designing H800N, we tried to eliminate unanticipated flaws in our H800 design. H800N has been designed to be more stable and reliable against quench without permanent damage by: (1) adopting a single solenoid structure composed of 40 stacked double pancake coils with improved cross-over sections; (2) enhancing thermal stability; and (3) reducing excessive current margin for quench protection.