Juha I. Peltonen

Juha I. Peltonen

Auto-generated profile, based on publicly available information

Juha I. Peltonen

HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Physica Medica
Verified
Journal Article
Closed access
KNKatri Nousiainen
Katri Nousiainen
TMTeemu Mäkelä
Teemu Mäkelä
APAnneli Piilonen
Anneli Piilonen
JPJuha I. Peltonen
Juha I. Peltonen

15 November 2021 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
RHReetta Hälvä
Reetta Hälvä
SVSatu M. Vaara
Satu M. Vaara
JPJuha I. Peltonen
Juha I. Peltonen
TKTouko Kaasalainen
Touko Kaasalainen
MHMiia Holmström
Miia Holmström
SSSuvi Syväranta
Suvi Syväranta
Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional (2D) flow and transthoracic echocardiography (TTE). We investigated the reliability of CMR 2D flow and 4D flow techniques in measuring aortic transvalvular peak systolic flow in patients with severe AS. We prospectively recruited 90 patients referred for aortic valve replacement due to severe AS (73.3 ± 11.3 years, aortic valve area 0.7 ± 0.1 cm2, and 54/36 tricuspid/bicuspid), and 10 non-valvular disease controls. All the patients underwent echocardiography and 2D flow and 4D flow CMR. Peak flow velocity measurements were compared using Wilcoxon signed rank sum test and Bland–Altman analysis. 4D flow underestimated peak flow velocity in the AS group when compared with TTE (bias − 1.1 m/s, limits of agreement ± 1.4 m/s) and 2D flow (bias − 1.2 m/s, limits of agreement ± 1.6 m/s). The differences between values obtained by TTE (median 4.3 m/s, range 2.7–6.1 m/s) and 2D flow (median 4.5 m/s, range 2.9–6.5 m/s) compared to 4D flow (median 3.1 m/s, range 1.7–5.1 m/s) were significant (p < 0.001). The difference between 2D flow and TTE were insignificant (bias 0.07 m/s, limits of agreement ± 1.5 m/s). In non-valvular disease controls, peak flow velocity was measured higher by 4D flow than 2D flow (1.4 m/s, 1.1–1.7 m/s and 1.3 m/s, 1.1–1.5 m/s, respectively; bias 0.2 m/s, limits of agreement ± 0.16 m/s). CMR 4D flow significantly underestimates systolic peak flow velocity in patients with severe AS. 2D flow, in turn, estimated the AS velocity accurately, with measured peak flow velocities comparable to TTE.

1 May 2014 in European Journal of Radiology
Verified
Journal Article
Closed access
PDF file
TKTouko Kaasalainen
Touko Kaasalainen
SPSami Pakarinen
Sami Pakarinen
SKSari Kivistö
Sari Kivistö
MHMiia Holmström
Miia Holmström
HHHelena Hänninen
Helena Hänninen
OSOuti Sipilä
Outi Sipilä

9 November 2024 in Physica Medica
Verified
Journal Article
Open access
JKJuuso H.J. Ketola
Juuso H.J. Ketola
SISatu I. Inkinen
Satu I. Inkinen
TMTeemu Mäkelä
Teemu Mäkelä
SSSuvi Syväranta
Suvi Syväranta
JPJuha Peltonen
Juha Peltonen
MKMika Kortesniemi
Mika Kortesniemi

10 November 2016 in Journal of Digital Imaging
Verified
Journal Article
Closed access
PDF file
JPJuha I. Peltonen
Juha I. Peltonen
TMTeemu Mäkelä
Teemu Mäkelä
ASAlexey Sofiev
Alexey Sofiev
ESEero Salli
Eero Salli

1 September 2017 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
AVAnne-Mari Vitikainen
Anne-Mari Vitikainen
JPJuha I. Peltonen
Juha I. Peltonen
EVEija Vartiainen
Eija Vartiainen