Sergii Shevchenko

Sergii Shevchenko

Auto-generated profile, based on publicly available information

Sergii Shevchenko

National Technical University “Kharkiv Polytechnic Institute

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018
Verified
Conference Paper
Closed access
SSSergey Shevchenko
Sergey Shevchenko
DDDmytro Danylchenko
Dmytro Danylchenko
SDStanislav Dryvetskyi
Stanislav Dryvetskyi
KMKseniia Minakova
Kseniia Minakova
Many years of experience in the construction and operation of 6 - 35 kV overhead power lines with bare wires showed insufficient reliability of such lines and their increased danger. One of the main causes of accidents and violations are thunderous overcharging on overhead lines, causing impulse overlap and destruction of insulators and leading to arc closures, with collateral damage to equipment, line outages. Emergency outages of 6 -35 kV overhead lines due to lightning overvoltages account for up to 40% of the total number of their trips. Due to low impulse strength, insulation of distribution networks is subject to overlapping both from over voltages in direct lightning discharges and from induced overvoltages in the case of lightning near the line. The latter are the main cause of thunderstorm outages and damage to the equipment of 6 -35 kV lines, amounting to 90% in some cases, and when the overhead lines highway passes through the forest and up to 100% of their total number. Thus, reliability of power supply to consumers largely depends on the effectiveness of lightning protection measures.

1 September 2015
Verified
Conference Paper
Closed access
SSShevchenko Sergey
Shevchenko Sergey
DDDanilchenko Dmitriy
Danilchenko Dmitriy
To article describes the experimental study on the nominal varistor voltage 6 - 10 kV, and the results of these studies. It shows the current voltage characteristics of varistors for different manufacturers. The influence of the effect on the current orientation of the varistor voltage characteristic of the arrester and leakage current. Illuminated issues of calculation of leakage current due to the uniqueness of each varistor and a lack of necessary data from the manufacturers. Practical recommendations that were developed the settlements and to select arresters for networks with low quality electric energy.

1 May 2017
Verified
Conference Paper
Closed access
SSSergey Shevchenko
Sergey Shevchenko
DDDmytro Danylchenko
Dmytro Danylchenko
The methods of determining the number of direct lightning strikes in overhead lines with protected wires. The calculation of the number of direct lightning strikes in overhead lines. Experimental study on a large-scale model of supporting change in the number of direct lightning strikes in overhead lines, depending on the type of wire. Identified lightning capture zone of overhead lines for medium voltage lines classes.

1 September 2015
Verified
Conference Paper
Closed access
SSShevchenko Sergey
Shevchenko Sergey
DDDanilchenko Dmitriy
Danilchenko Dmitriy
The aim of the article is to determine, by experiment on large-scale models, the probability of direct lightning strikes in overhead lines with protected wires for different model configurations. The experimental results have allowed to refute the hypothesis of the absence of direct impacts in protected wires of overhead lines. The studies conducted suggest that lightning defeat of overhead lines with protected wires is substantially lower than that traditional lines.

15 May 2019 in Energetika
Verified
Journal Article
Open access
PDF file
IDIllia Diahovchenko
Illia Diahovchenko
Roman MykhailyshynRoman Mykhailyshyn
Roman Mykhailyshyn
DDDmytro Danylchenko
Dmytro Danylchenko
SSSerhii Shevchenko
Serhii Shevchenko
Electric energy measurement errors depend on the design and algorithms used in electricity meters, as well as on the auxiliary and embedded sensors’ accuracy and bandwidth (or more precisely, maximum measurable frequency). Poor power quality may affect the electric energy meters accuracy, which will lead to the improper power accounting. In this article the applications of the Rogowsky coil sensors for electric energy measurement are studied. The advantages and the challenges of this sensor type implementation are discussed, and the operation scheme of the power meter for the separate measurement of the fundamental harmonic’s electric energy and the higher harmonics electric energy is proposed. The possibility of implementation of responsibility determining methods for power quality distortion is highlighted.

14 February 2018 in Energetika
Verified
Journal Article
Closed access
PDF file
SSSerhii Yu. Shevchenko
Serhii Yu. Shevchenko
VVVitalii V. Volokhin
Vitalii V. Volokhin
IDIllia Diahovchenko
Illia Diahovchenko
Problems of power quality and electric energy accounting often occur in networks with large pervasion of photovoltaic (PV) elements on rooftops of household and office buildings. In smart grids, including PV arrays electricity, which is sold back to the distribution network, requires approval of its parameters and quality control. Distributed power inverters generate higher harmonics which affect relay protection, automation systems, smart meters and power system’s reliability. In this article the influence of photovoltaic elements on the accuracy of electric energy metering and power quality questions are analysed.