In the article the circuit design solution of DC-DC regulated resonant converter has been proposed for using with hybrid photovoltaic modules which has cooling equipment and solar concentrators in order to maximize electric power generating by such module. By using computer simulation based on multiple iterations algorithm we significantly increase the accuracy of determining the resonance circuit optimal parameters for build up DC–DC converters to work in a wide range of electric powers. Based on optimal values of the resonance LLC scheme parameters, achived by numerical calculation it can be show high values of electrical energy transformation efficiency for photovoltaic energy station equipped with high efficiency hybrid photovoltaic modules. Implementation of microprocessor-based control into design of DC–DC back-boost converters create a new possibility to build control algorithms for increase reliability and conversion efficiency, rapid and precision stabilization of maximum power point, implementation network monitoring of photovoltaic modules, converters itself and the whole photovoltaic station parameters.
Many years of experience in the construction and operation of 6 - 35 kV overhead power lines with bare wires showed insufficient reliability of such lines and their increased danger. One of the main causes of accidents and violations are thunderous overcharging on overhead lines, causing impulse overlap and destruction of insulators and leading to arc closures, with collateral damage to equipment, line outages. Emergency outages of 6 -35 kV overhead lines due to lightning overvoltages account for up to 40% of the total number of their trips. Due to low impulse strength, insulation of distribution networks is subject to overlapping both from over voltages in direct lightning discharges and from induced overvoltages in the case of lightning near the line. The latter are the main cause of thunderstorm outages and damage to the equipment of 6 -35 kV lines, amounting to 90% in some cases, and when the overhead lines highway passes through the forest and up to 100% of their total number. Thus, reliability of power supply to consumers largely depends on the effectiveness of lightning protection measures.
Telemedical system for monitoring the psycho-neurological state for rehabilitation is evolving for assessment and supervision of various neurological syndromes. Persons with disabilities are not a homogenous group, they are facing multiple problems in their daily life. Common problem of people with disabilities and old aged people is that they have lacked access to basic services. Nowadays researchers are focused on human computer interaction-based rehabilitation technologies that bring social-emotional intelligence closer. The paper is designed to achieve cognitive rehabilitation using machine learning approaches for disabled and elderly people. Electroencephalograms are used to monitor brain activity of the human brain and Kinect sensors are used to track users' movements. Chebyshev filter used to remove noise, for feature extraction Autoencoder technique is used, and classification is done by Transfer learning based Convolutional neural network with 95% and above accuracy. The proposed system will be applied in real time to achieve a better quality of life for disabled and elderly people.
The methods of determining the number of direct lightning strikes in overhead lines with protected wires. The calculation of the number of direct lightning strikes in overhead lines. Experimental study on a large-scale model of supporting change in the number of direct lightning strikes in overhead lines, depending on the type of wire. Identified lightning capture zone of overhead lines for medium voltage lines classes.
This article proposes an approach towards combating power meters tampering by manipulation with strong magnetic fields. The vulnerabilities of electronic power meters are highlighted, and different shielding structures for limiting electromagnetic interference on power meters are investigated. Simulations were performed using the CST EM Studio simulation tool, exploiting the finite element method. The techniques for optimization of shield’s dimensions and shape are studied.
Electric energy measurement errors depend on the design and algorithms used in electricity meters, as well as on the auxiliary and embedded sensors’ accuracy and bandwidth (or more precisely, maximum measurable frequency). Poor power quality may affect the electric energy meters accuracy, which will lead to the improper power accounting. In this article the applications of the Rogowsky coil sensors for electric energy measurement are studied. The advantages and the challenges of this sensor type implementation are discussed, and the operation scheme of the power meter for the separate measurement of the fundamental harmonic’s electric energy and the higher harmonics electric energy is proposed. The possibility of implementation of responsibility determining methods for power quality distortion is highlighted.