20 June 2019 in IEEE Transactions on Antennas and Propagation
A dual-band, low profile, high gain, and low SAR triangular slotted monopole antenna backed with a 4×4 AMC array is presented for Wireless Body Area Network (WBAN) applications. The antenna is printed on Rogers ULTRALAM 3850 substrate, whereas the AMC array is printed on RO3003 substrate. The design operates at 3.5 GHz, for WiMAX wireless application, and 5.8 GHz of the ISM Band. The proposed antenna preserved dual-band resonance and exhibited acceptable gain and SAR at a separation of 15 mm from the human body model. To reduce such separation and achieve enhancements to gain and SAR, an AMC array was utilized. In free space, gain enhancements by 6.8 dBi and 3.7 dBi were achieved at both frequencies, respectively. Furthermore, over a gap of 1 mm from the human body, gain enhancements by 23.3 dBi and 13.9 dBi were achieved at both frequencies, respectively. In addition, SAR reductions by almost 99% were attained. The antenna was fabricated and measured where a high agreement was met between simulated and measured results, with and without the incorporated AMC array. With such results, the proposed design can be highly recommended for wearable medical applications, specifically for diabetic patients.
18 January 2016 in IEEE Antennas and Wireless Propagation Letters
In this letter, a graphene nanoflakes printed antenna is presented. Graphene nanoflakes conductive ink has been screenprinted on paper substrate and compressed to achieve the conductivity of 0.43 × 10 5 S/m. Low-profile meandered-line dipole antenna has been fabricated as a proof of concept due to its electrically small size and simple structure. The maximum gain is measured to be -4 dBi, the -10-dB bandwidth ranges from 984 to 1052 MHz (6.67%), and the radiation pattern is verified as being typical radiation patterns of a dipole-type antenna. The radiation efficiency is 32%. The measurement results reveal that graphene nanoflakes printed antenna can provide practically acceptable return loss, gain, bandwidth, and radiation patterns for midand short-range RFID, and sensing applications. Furthermore, screenprinting technique employed in this work is of extremely low cost and capable of producing antennas in mass production.
6 November 2013 in IEEE Antennas and Wireless Propagation Letters
This letter presents a design of a two-element multiple-input-multiple-output (MIMO) metamaterial-based antenna. The two antenna elements operate at 5.8 GHz for wireless applications. The two antenna elements are designed employing only one left-handed unit cell. The reduction of mutual coupling between the two antenna elements is achieved by using a simple defected ground structure between them to limit the surface waves between them. The distance between the two antenna elements is only 1.8 mm (0.034 λ0). The designed antenna elements have better than -45 dB coupling isolation between the two inputs. Moreover, the proposed MIMO antenna has the advantage of compactness (its size is only 2.36 × 2.6 cm2). The design represents size reduction of more than 50% compared to conventional patch antennas operating at the same frequency. The proposed MIMO system has -55 dB correlation coefficient between its two elements.
2 April 2019 in Journal of Applied Physics
A polarization independent conformal wideband metamaterial absorber has been proposed in this study. The proposed absorber unit cell consists of a circle and a slotted sector, loaded with four lumped resistors between them to improve the absorption bandwidth. Measured and simulated results exhibit more than 90% absorption in the frequency band from 3.90 GHz to 10.5 GHz under the normal incidence angle, and the fractional bandwidth is 91.6%. The proposed absorber is polarization independent due to the symmetrical nature. The absorber unit cell is compact in configuration with a unit cell size of 0.16 λo × 0.16 λo, where λo is the wavelength at 3.9 GHz and the substrate thickness is 0.098 λo. Once the proposed absorber is wrapped on the cylindrical surface, it shows good absorptivity in the absorption frequency band. The effects of many designed parameters have been studied to understand the performance of the wideband absorber. To recognize the absorption phenomenon of the absorber, normalized impedance, electric field distribution, and surface current density have been demonstrated. Finally, the proposed conformal absorber fabricated and measured the absorption for flat and curved surfaces, which exhibits good agreement between the simulated and the experimental results.
5 December 2022 in IEEE Transactions on Antennas and Propagation
This paper shows how to reduce the radar cross-section by employing two artificial magnetic conductor metasurface unit cells. The two AMCs cells are arranged in chessboard configuration to decrease both monostatic and also bistatic radar cross-section using low-cost FR4 material. A 10 dB reducing in RCS can be obtained when the difference in phase between the reflected wave from AMC1 and AMC2 will be (180° ± 37°) to make the waves that reflect from AMC1 and AMC2 interfere destructively. A significant reduction in RCS of checkerboard metasurface can be observed. The measured X-pol and Y-pol monostatic RCS of the proposed chessboard surface indicate that the reduction in RCS is over a frequency band from 23.71 GHz to 33.52 GHz for X-pol and from 25 GHz to 37.8 GHz for Y-pol with a maximum reduction in RCS of -27 dB for X-pol and maximum reduction of -25.9 dB for Y-pol. The bistatic RCS of the chessboard metasurface is reduced also and the incident plane wave scatters into five lobes in different directions.
1 May 2020 in IET Microwaves, Antennas & Propagation
A high gain, low specific absorption rate, oval‐shaped monopole antenna is presented. It is backed by an all‐textile 3 × 3 array of electromagnetic bandgap (EBG) unit cells. The antenna is printed on the thin Rogers ULTRALAM 3850 substrate, while the EBG array is composed of the conductive ShieledIT Super and dielectric substrate felt. The design operates at 2.45 GHz of the Industrial, Scientific, and Medical band. Due to the close distance between the extended grounds of the co‐planar waveguide feeding configuration and the oval‐shaped monopole antenna, current‐coupling was achieved, leading to gain enhancement. However, with body‐loading cases, resonance at 2.45 GHz was attained at a separation of 30 mm. By incorporating the EBG array, as an isolator, this issue was resolved. In free space and over a gap of 3 mm from the human body, gain enhancements by 2.68 and 11.54 dB were achieved at 2.45 GHz, respectively. Simulated and measured results are benchmarked. Furthermore, SAR simulation study showed reductions by 99.5%, averaged over 1 and 10 g of tissue.