Alexander Utz

Alexander Utz

Auto-generated profile, based on publicly available information

Alexander Utz

Faculty of Information, Media and Electrical Engineering, Institute of Applied Optics and Electronics, Kln, Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AUAlexander Utz
Alexander Utz
CWChristian Walk
Christian Walk
ASAlexander Stanitzki
Alexander Stanitzki
MMMir Mokhtari
Mir Mokhtari
MKMichael Kraft
Michael Kraft
RKRainer Kokozinski
Rainer Kokozinski
In this paper, we present a capacitive, MEMS-based accelerometer comprising an ultra-low noise CMOS integrated readout-IC and a high-precision bulk micro machined sensing element. The resulting accelerometer reaches an acceleration equivalent noise of only 200 ng/√Hz, which makes it suitable for seismic measurement that require noise levels significantly below 1 μg/√Hz. Additionally, a high bandwidth of more than 5 kHz was achieved, which also makes the presented sensor system applicable for high-frequency measurements, e.g. in predictive maintenance applications for rotating machinery. The design of the sensing element and readout IC is presented in detail and measurement results are shown which demonstrate the performance of the sensor system.

22 August 2017 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
AUAlexander Utz
Alexander Utz
CWChristian Walk
Christian Walk
NHNorbert Haas
Norbert Haas
TFTatjana Fedtschenko
Tatjana Fedtschenko
ASAlexander Stanitzki
Alexander Stanitzki
RKRainer Kokozinski
Rainer Kokozinski
In this paper we present a readout circuit for capacitive micro-electro-mechanical system (MEMS) sensors such as accelerometers, gyroscopes or pressure sensors. A flexible interface allows connection of a wide range of types of sensing elements. The ASIC (application-specific integrated circuit) was designed with a focus on ultra-low noise operation and high analog measurement performance. Theoretical considerations on system noise are presented which lead to design requirements affecting the reachable overall measurement performance. Special emphasis is put on the design of the fully differential operational amplifiers, as these have the dominant influence on the achievable overall performance. The measured input referred noise is below 50 zF/Hz within a bandwidth of 10 Hz to 10 kHz. Four adjustable gain settings allow the adaption to measurement ranges from ±750 fF to ±3 pF. This ensures compatibility with a wide range of sensor applications. The full input signal bandwidth ranges from 0 Hz to more than 50 kHz. A high-precision accelerometer system was built from the described ASIC and a high-sensitivity, low-noise sensor MEMS. The design of the MEMS is outlined and the overall system performance, which yields a combined noise floor of 200 ng/Hz, is demonstrated. Finally, we show an application using the ASIC together with a CMOS integrated capacitive pressure sensor, which yields a measurement signal-to-noise ratio (SNR) of more than 100 dB.

1 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IHIngo Hoyer
Ingo Hoyer
AUAlexander Utz
Alexander Utz
ALAndré Lüdecke
André Lüdecke
HKHolger Kappert
Holger Kappert
MRMaurice Rohr
Maurice Rohr
KSKarsten Seidl
Karsten Seidl
Atrial Fibrillation (AF) is one of the most common heart arrhythmias. It is known to cause up to 15% of all strokes. In current times, modern detection systems for arrhythmias, such as single-use patch electrocardiogram (ECG) devices, have to be energy efficient, small, and affordable. In this work, specialized hardware accelerators were developed. First, an artificial neural network (NN) for the detection of AF was optimized. Special attention was paid to the minimum requirements for the inference on a RISC-V-based microcontroller. Hence, a 32-bit floating-point-based NN was analyzed. To reduce the silicon area needed, the NN was quantized to an 8-bit fixed-point datatype (Q7). Based on this datatype, specialized accelerators were developed. Those accelerators included single-instruction multiple-data (SIMD) hardware as well as accelerators for activation functions such as sigmoid and hyperbolic tangents. To accelerate activation functions that require the e-function as part of their computation (e.g., softmax), an e-function accelerator was implemented in the hardware. To compensate for the losses of quantization, the network was expanded and optimized for run-time and memory requirements. The resulting NN has a 7.5% lower run-time in clock cycles (cc) without the accelerators and 2.2 percentage points (pp) lower accuracy compared to a floating-point-based net, while requiring 65% less memory. With the specialized accelerators, the inference run-time was lowered by 87.2% while the F1-Score decreased by 6.1 pp. Implementing the Q7 accelerators instead of the floating-point unit (FPU), the silicon area needed for the microcontroller in 180 nm-technology is below 1 mm2.

23 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
TFTatjana Fedtschenko
Tatjana Fedtschenko
AUAlexander Utz
Alexander Utz
ASAlexander Stanitzki
Alexander Stanitzki
AHAndreas Hennig
Andreas Hennig
ALAndre Lüdecke
Andre Lüdecke
RKRainer Kokozinski
Rainer Kokozinski
This article presents a new configurable wireless sensor system. The system is used to perform amperometric measurements and send the measurement data to a handheld reader using a wireless transponder interface. The two-chip sensor system was implemented in a 0.35 μm CMOS technology. The system consists of an integrated nano-potentiostat that performs the actual measurements and an ISO 18000-3 compliant frontend that enables wireless telemetric data transmission and powering of the entire sensor system. The system was manufactured in combination with a chronoamperometric glucose sensor which allows the measurement of the glucose content in tear fluid and thus a non-invasive determination of the blood sugar level. For a range of sensor currents from 0.1 μA to 10 μA, the potentiostat achieved an accuracy of better than 5 % with a total power dissipation of less than 600 μW. With the realized antenna geometry a wireless communication distance of more than 7 cm has been achieved.

29 January 2025 in Physiological Measurement
Verified
Journal Article
Open access
IHIngo Hoyer
Ingo Hoyer
AUAlexander Utz
Alexander Utz
Christoph Hoog AntinkChristoph Hoog Antink
Christoph Hoog Antink
KSKarsten Seidl
Karsten Seidl
Objective. In recent years, wearable devices such as smartwatches and smart patches have revolutionized biosignal acquisition and analysis, particularly for monitoring electrocardiography (ECG). However, the limited power supply of these devices often precludes real-time data analysis on the patch itself. Approach. This paper introduces a novel Python package, tinyHLS (High Level Synthesis), designed to address these challenges by converting Python-based AI models into platform-independent hardware description language code accelerators. Specifically designed for convolutional neural networks, tinyHLS seamlessly integrates into the AI developer’s workflow in Python TensorFlow Keras. Our methodology leverages a template-based hardware compiler that ensures flexibility, efficiency, and ease of use. In this work, tinyHLS is first-published featuring templates for several layers of neural networks, such as dense, convolution, max and global average pooling. In the first version, rectified linear unit is supported as activation. It targets one-dimensional data, with a particular focus on time series data. Main results. The generated accelerators are validated in detecting atrial fibrillation on ECG data, demonstrating significant improvements in processing speed (62-fold) and energy efficiency (4.5-fold). Quality of code and synthesizability are ensured by validating the outputs with commercial ASIC design tools. Significance. Importantly, tinyHLS is open-source and does not rely on commercial tools, making it a versatile solution for both academic and commercial applications. The paper also discusses the integration with an open-source RISC-V and potential for future enhancements of tinyHLS, including its application in edge servers and cloud computing. The source code is available on GitHub: https://github.com/Fraunhofer-IMS/tinyHLS

6 September 2023
Verified
Conference Paper
Closed access
DRDomenico Ragusa
Domenico Ragusa
AAAntonio José Rodríguez Almeida
Antonio José Rodríguez Almeida
SNStephan Nolting
Stephan Nolting
Emanuele TortiEmanuele Torti
Emanuele Torti
Himar FabeloHimar Fabelo
Himar Fabelo
FLFrancesco Leporati
Francesco Leporati
Cardiovascular diseases (CVDs) are currently one of the leading causes of death worldwide. Being able to detect their symptoms at early stages, even the most hidden ones, is crucial to shorten the diagnosis time and facilitate an early treatment. Currently, the use of continuous tracking systems, mainly based on wearable devices that analyze data using artificial intelligence (AI) algorithms, is being explored to automatically identify, in real time, CVDs symptoms. This could be especially relevant in lowincome countries where there is a shortage of specialized doctors. Therefore, this work focuses on analyzing the real-time execution of the state-of-the-art convolutional neural network (CNN) for heart sound segmentation (HSS) on platforms such as traditional CPU/GPU and the Fraunhofer IMS © AIRISC Core Complex (a RISC-V processor developed for AI). Results revealed that, while all implementations exploiting the CPU/GPU platform proved to be useful in real-time diagnosis from a fixed location, the AIRISC demonstrated its goodness, as a system on a chip (SoC) for a real-time wearable application, when executing a quantized version of the CNN.