To monitor biofilm growth on polydimethylsiloxane in a photobioreactor effectively, the biofilm cells and liquids were separated and measured using a sensor with two U-shaped, double-tapered, fiber-optic probes (Sen. and Ref. probes). The probes’ Au-coated hemispherical tips enabled double-pass evanescent field absorption. The Sen. probe sensed the cells and liquids inside the biofilm. The polyimide–silica hybrid-film-coated Ref. probe separated the liquids from the biofilm cells and analyzed the liquid concentration. The biofilm structure and active biomass were also examined to confirm the effectiveness of the measurement using a simulation model. The sensor was found to effectively respond to the biofilm growth in the adsorption through exponential phases at thicknesses of 0–536 μm.
Although the numerous advantages of polymer optical fiber (POF) sensors have been applied in different fields, the measurement consistency and sensitivity of POF evanescent wave (EW) sensors are still affected by its thermal stability and water absorption. Therefore, we perform a study to demonstrate the mechanism of the effect of heat treatments on physical and optical properties of POF EW sensors. We investigate the surface morphology, composition, refractive index, geometry, and weight of the fiber-sensing region subjected to water and vacuum heat treatments. We examine the spectral transmission and transmitted light intensity of POF sensors. We present a theoretical investigation of the effect of heat treatments on the sensitivity of POF EW sensors. The performance of the prepared sensor is evaluated using glucose and Chlorella pyrenoidosa analytes. We discovered that the spectral transmission and transmitted light intensity of the fibers shows little effect of vacuum heat treatments. In particular, the sensors, which subject to vacuum heat treatment at 110 °C for 3 h, exhibit temperature-independent measuring consistency and high sensitivity in glucose solutions in the temperature range 15–60 °C and also show high sensitivity in Chlorella pyrenoidosa solutions.
1 September 2023 in IEEE/ASME Transactions on Mechatronics
In climbing robots, weak grasping, large size, and a lack of self-perception capability are critical problems that urgently need to be solved. Inspired by the excellent grasping ability of primate hands and the simple locomotion method of inchworms, this study proposes an inchworm-like climbing robot based on synergistic cable-driven grippers and a telescopic torso. First, the overall structure of the climbing robot was designed by analyzing the characteristic movements of primate hands and inchworms. Next, a cable-driven soft gripper was designed based on geometric, modulus, and motion similarity with primate hands using dimensionless analysis. Then, a telescopic climbing robot torso was designed to mimic the peristalsis motion of inchworms by using double flexible thin-shelled rods that bend easily in the forward direction and resist movement in the reverse direction. Subsequently, flexible tensile strain sensors were designed based on carbon nanotubes and iron nanowires and then integrated into the soft grippers and torso for self-perception of the motion state. Subsequently, flexible sensors, soft grippers, and a telescopic torso were fabricated using casting and dipping–pulling technology. Finally, the climbing performance of the robot was experimentally tested. The results indicate that the robot can stably climb pipes with different roughness and diameters, and the embedded sensors can capture the motion of the gripper and torso. The climbing speed of the robot was 3.3 mm/s for horizontal pipes and 1.0 mm/s for vertical pipes.
This study introduces a new wearable fiber-optic sensor glove. The glove utilizes a flexible material, polydimethylsiloxane (PDMS), and a silicone tube to encapsulate fiber Bragg gratings (FBGs). It is employed to enable the self-perception of hand posture, gesture recognition, and the prediction of grasping objects. The investigation employs the Support Vector Machine (SVM) approach for predicting grasping objects. The proposed fiber-optic sensor glove can concurrently monitor the motion of 14 hand joints comprising 5 metacarpophalangeal joints (MCP), 5 proximal interphalangeal joints (PIP), and 4 distal interphalangeal joints (DIP). To expand the measurement range of the sensors, a sinusoidal layout incorporates the FBG array into the glove. The experimental results indicate that the wearable sensing glove can track finger flexion within a range of 0° to 100°, with a modest minimum measurement error (Error) of 0.176° and a minimum standard deviation (SD) of 0.685°. Notably, the glove accurately detects hand gestures in real-time and even forecasts grasping actions. The fiber-optic smart glove technology proposed herein holds promising potential for industrial applications, including object grasping, 3D displays via virtual reality, and human–computer interaction.
Toxoplasma gondii (T. gondii) is a zoonotic parasite that is widely distributed and seriously endangers public health and human health. Therefore, accurate and effective detection of T. gondii is crucial. This study proposes a microfluidic biosensor using a thin-core microfiber (TCMF) coated with molybdenum disulfide (MoS2) for immune detection of T. gondii. The single-mode fiber was fused with the thin-core fiber, and the TCMF was obtained by arc discharging and flame heating. In order to avoid interference and protect the sensing structure, the TCMF was encapsulated in the microfluidic chip. MoS2 and T. gondii antigen were modified on the surface of TCMF for the immune detection of T. gondii. Experimental results showed that the detection range of the proposed biosensor for T. gondii monoclonal antibody solutions was 1 pg/mL to 10 ng/mL with sensitivity of 3.358 nm/log(mg/mL); the detection of limit was calculated to be 87 fg/mL through the Langmuir model; the dissociation constant and the affinity constant were calculated to be about 5.79 × 10−13 M and 1.727 × 1014 M−1, respectively. The specificity and clinical characteristics of the biosensor was explored. The rabies virus, pseudorabies virus, and T. gondii serum were used to confirm the excellent specificity and clinical characteristics of the biosensor, indicating that the proposed biosensor has great application potential in the biomedical field.