3 June 2024 in IEEE Transactions on Plasma Science
The Divertor Tokamak Test (DTT) facility is a fusion device under construction in Italy. The mission of DTT is to test alternative divertor concepts under integrated physics and technological conditions that can reliably be extrapolated to DEMO. Due to the plasma core characteristics with relevant edge and scrape-off layer (SOL) parameters and a wall entirely in tungsten (W), DTT will provide an extensive set of information useful to select the most appropriate strategy for the power exhaust in DEMO. Several divertors, which may differ in design or/and technologies or/and poloidal profile, will be tested during the life of the machine. The first divertor to be installed will have to accommodate a multitude of strike points, located at various positions according to the different magnetic configurations, which will be tested in the first operational phases of the machine with the aim to identify the most promising. The first divertor will not test innovative technological solutions but will mainly take advantage of the technologies already qualified for the ITER divertor production. Thus, the entire divertor plasma-facing surface is designed to be used as targets: it will be made of W monoblocks joined on CuCrZr pipes (plasma-facing units, PFUs) similar to the ITER targets. With the purpose to increase the flexibility in operational scenarios by maximizing the allowable thermal load for the PFUs, the possibility of using monoblocks with a plasma side reduced thickness was investigated. By reducing the thickness of the armor, it is possible to limit plastic deformation of the monoblock and to preserve the characteristics of the plasma-facing surface during the component lifetime. A thickness between 3 and 4 mm is compatible both the erosion estimates in the DTT divertor area and the manufacturing constraints and therefore proposed for the DTT PFUs. Several mock-ups based on monoblock design were in the past tested under thermal fatigue, confirming the reliability of the monoblock design and the manufacturing processes, but with larger armor thicknesses (6–8 mm). The experimental verification of the monoblock performance with the proposed reduced thickness has been verified in the GLADIS facility at IPP Garching with a thermal load of 20 MW/m $^{2}$ applied for 1000 cycles of 10 s. The results showed the absence of plastic deformation and negligible increase in surface roughness.
11 April 2024 in IEEE Transactions on Plasma Science
The main mission of the divertor tokamak test (DTT) facility is to study advanced solutions for the power exhaust issue in view of a fusion power plant. In this respect, a significant amount of heat is expected to be absorbed by the first wall (FW) during operation. Therefore, the DTT FW is designed to be an actively water-cooled system. A proper hydraulic model is needed for the development of a cooling architecture of the system able to fulfill the requirements of operational safety under thermal loads and compliance with the DTT plant specifications. The present study aims to address this challenge, offering practical inputs for further optimization. Based on the existing conceptual design, the cooling circuits have been setup inside the plasma-facing components (PFCs). In this phase, empirical equations and hydraulic simulations have been adopted to investigate the hydraulic behavior of the modules that make up the FW and to evaluate the main design parameters, namely, velocity and pressure drops in the cooling channels. The outcome of such analysis demonstrated that the current design of the FW system complies with the imposed requirements. Moreover, operating flexibility has been demonstrated by identifying a proper range of the mass flow rate for each subsystem. Therefore, the models implemented in this study and the obtained findings prove to be suitable to support the next activities of engineering design of the FW.
17 April 2024 in IEEE Transactions on Plasma Science
The divertor tokamak test (DTT) facility is currently in the design stage and in the initial phase of construction at the research center ENEA Frascati. The DTT facility aims at searching integrated solutions for the power exhaust issue maintaining plasma performances compatible with future fusion devices. For this reason, the first DTT divertor was designed to accommodate different magnetic configurations: in particular other than single null (SN), the compatibility with X-divertor (XD) and negative triangularity (NT) with different leg lengths was ensured. To accommodate the strike point positions of the different magnetic equilibria, all plasma facing surfaces (i.e., inner and outer vertical targets, as well as the dome) have to be entirely made of tungsten (W) monoblocks. At the same time, to leave more space to the divertor legs, it was decided to design a dome with a flat shape. These two factors along with the armor with W monoblock and the flat shape have required finding ad hoc technological solutions for the plasma facing units (PFUs) of the dome with the need of a research and qualification phase. Above all, a W flat tiles (FTs) design was required at the inner dome end, where the copper cooling pipes turn by 90 $^{\circ}$ . The FT segment covers only a small length of the PFU ( $\sim$ 40 mm), and the goal is to join both monoblock and FT segments to the pipe in a single manufacturing process. The technique used is the hot radial pressing (HRP), which has been developed in ENEA and qualified for the manufacturing of the ITER inner vertical target.
15 July 2025 in Fusion Engineering and Design
12 April 2024 in IEEE Transactions on Plasma Science
This article describes the solutions investigated for the design of the support and fixation systems of the first wall (FW) to the vacuum vessel (VV) at both inboard and outboard sides, in order to define their engineering design in compliance with the other involved systems of the divertor tokamak test (DTT) facility: VV, diagnostics, remote handling (RH), and plasma physics. The aim is to engineer them to cope with the electromagnetic (EM) loads resulting from disruption events (VDE and MD) or from discharges occurring in the coils (i.e., toroidal field coils fast discharge).