To assess the feasibility of thoracoscopic transdiaphragmatic approach for biopsy of all lung lobes and to determine the optimal intercostal space (ICS) for biopsy of each lung lobe. Ten rabbits were positioned in dorsal recumbency. Total thoracoscopy lung biopsy was made combined transdiaphragmatic approach and right ICS approaches. A camera port was made in the transdiaphragmatic approach and the instrument port was made of ICS 7 and ICS 9. A pre tied loop ligature was placed to performed a caudal lung lobe biopsy and to simulate biopsies of the others lung lobes. Biopsy of the cranial aspect of the right caudal lung lobe was performed at ICS 9. Simulated biopsy of the accessory lung lobe was performed at ICS 9. Simulated lung biopsy of the right cranial and middle lung lobes was performed at ICS 7. The caudal and dorsal aspect of the right caudal lung lobe was not visualized by telescope at transdiaphragmatic approach, and biopsy was not performed. Thoracoscopic transdiaphragmatic approach for lung lobes biopsies was a feasible technique, except for the caudal aspect of the right caudal lung lobe. An ideal intercostal port for biopsy of each right lung lobe was determined.
1 October 2019 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey’s test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.
The aim of this randomized study was to compare the complications and perioperative outcome of three different techniques of laparoscopic cholecystectomy (LC). Changes in the liver function test after LC techniques were investigated. Also, we compared the degree of postoperative adhesions and histopathological changes of the liver bed.
1 October 2022 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
The aim of this study was to develop a modified tibial plateau leveling osteotomy (TPLO) plate and to compare its biomechanical properties with a locking compression plate (LCP) and plate-rod constructs for the stabilization of experimentally induced gap fractures in canine synthetic tibias. The tibial models were assigned to either repair with a modified TPLO plate (Group 1), locking compression plate construct (Group 2), or plate-rod construct (Group 3). The specimens were loaded to failure in axial compression, three-point mediolateral and craniocaudal bending. There was no statistical difference between the three groups regarding stiffness (N/mm) and deformation (mm) in axial compression. The modified TPLO plate achieved load to failure similar to the plate-rod construct in craniocaudal bending. There was no significant difference between groups on mediolateral bending tests regarding load to failure and deformation. Furthermore, there was no significant difference in stiffness between groups 1 and 2. In conclusion, the modified TPLO plate had similar mechanical properties to LCP and plate-rod construct in the axial compression and bending tests. Nonetheless, clinical studies with a large population of dogs are required to determine the value of this new implant in proximal tibial fracture repair.
Studies have demonstrated that the LigaSure device causes less tissue damage than bipolar electrosurgery. Increases and decreases in protein and immunoglobulin concentrations after laparoscopic cholecystectomy are expected and transient. This study aimed to compare serum values of acute-phase proteins and immunoglobulins in rabbits undergoing gallbladder dissection using bipolar electrosurgery (Maryland forceps) and vessel sealing device (VSD) LigaSure. The objective was to determine which method resulted in less inflammatory change. Twenty rabbits were divided into two groups of ten each. Group 1 underwent laparoscopic cholecystectomy with bipolar electrosurgical forceps for dissection and LigaSure for sealing the cystic duct. Group 2 underwent dissection and cystic duct sealing using VSD-LigaSure only. Acute-phase proteins and immunoglobulins were evaluated on postoperative days three, seven, and fifteen. Serum concentrations of fibrinogen, transferrin, IgG, α1-acid glycoprotein, PM 23000 Da, and C-reactive protein (CRP) did not differ significantly between groups. However, significant differences were observed between evaluation days within the same group. IgA, ceruloplasmin, and haptoglobin were not statistically analyzed for either group or day comparisons. Only albumin levels differed between groups, with group 1 showing a lower protein concentration on day 15. Both methods caused changes in acute-phase proteins, indicating no significant advantage for using the LigaSure device.
Resumo Estudos demonstram que o dispositivo selante de vasos DSV-LigaSure promove menor dano tecidual que o eletrocirúrgico bipolar e o aumento e diminuição das concentrações de proteínas e imunoglobulinas após a colecistectomia laparoscópica é esperado e transitório. Objetivou-se comparar os valores séricos das proteínas de fase aguda e imunoglobulinas de coelhos submetidos à dissecção da vesícula biliar utilizando eletrocirúrgico bipolar (pinça Maryland) e DSV-LigaSure para determinar qual dos dissectores apresentou menor alteração inflamatória. Vinte coelhos foram distribuídos em dois grupos com dez animais cada, sendo o Grupo 1 submetido à técnica de colecistectomia laparoscópica utilizando o eletrocirúrgico bipolar para dissecção e DSV-LigaSure para selar o ducto cístico e o Grupo 2, submetido à dissecção da vesícula biliar e selagem do ducto cístico utilizando o DSV-LigaSure. As proteínas de fase aguda e imunoglobulinas foram avaliadas nos dias três, sete e 15 do período pós-operatório. As concentrações séricas de fibrinogênio, transferrina, IgG, α1- glicoproteína ácida, PM 23000 Da e proteína C reativa não apresentaram diferenças significativas entre os grupos, apenas diferenças significativas entre os dias de avaliação no mesmo grupo. IgA, ceruloplasmina e haptoglobina não apresentaram diferenças estatísticas entre grupos e nem entre dias de avaliação. Apenas albumina apresentou diferença entre grupos, onde o Grupo 1 demonstrou menor concentração da proteína após 15 dias. Ambos dissectores apresentaram alterações nas proteínas de fase aguda, demonstrando que não houve superioridade na técnica utilizando o DSV-LigaSure.