Monica Carolina Nery Wittmaack

Monica Carolina Nery Wittmaack

Auto-generated profile, based on publicly available information

Monica Carolina Nery Wittmaack

Universidade Estadual Paulista, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
PDF file
MWMonica Carolina Nery Wittmaack
Monica Carolina Nery Wittmaack
FBFelipe Farias Pereira da Câmara Barros
Felipe Farias Pereira da Câmara Barros
PSPaloma Do Espírito Santo Silva
Paloma Do Espírito Santo Silva
AMAndresa Matsui
Andresa Matsui
GSGuilherme Sembenelli
Guilherme Sembenelli
PMPaola Moraes
Paola Moraes
To assess the feasibility of thoracoscopic transdiaphragmatic approach for biopsy of all lung lobes and to determine the optimal intercostal space (ICS) for biopsy of each lung lobe. Ten rabbits were positioned in dorsal recumbency. Total thoracoscopy lung biopsy was made combined transdiaphragmatic approach and right ICS approaches. A camera port was made in the transdiaphragmatic approach and the instrument port was made of ICS 7 and ICS 9. A pre tied loop ligature was placed to performed a caudal lung lobe biopsy and to simulate biopsies of the others lung lobes. Biopsy of the cranial aspect of the right caudal lung lobe was performed at ICS 9. Simulated biopsy of the accessory lung lobe was performed at ICS 9. Simulated lung biopsy of the right cranial and middle lung lobes was performed at ICS 7. The caudal and dorsal aspect of the right caudal lung lobe was not visualized by telescope at transdiaphragmatic approach, and biopsy was not performed. Thoracoscopic transdiaphragmatic approach for lung lobes biopsies was a feasible technique, except for the caudal aspect of the right caudal lung lobe. An ideal intercostal port for biopsy of each right lung lobe was determined.

1 October 2019 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Verified
Journal Article
Open access
PDF file
GSG. Sembenelli
G. Sembenelli
ASA.C. Shimano
A.C. Shimano
MWM.C.N. Wittmaack
M.C.N. Wittmaack
TRThiago ANDRÉ Salvitti de Sá Rocha
Thiago ANDRÉ Salvitti de Sá Rocha
PMPaola Moraes
Paola Moraes
LDL.G.G.G. Dias
L.G.G.G. Dias
The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey’s test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.

1 January 2023 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
PDF file
MWMonica Carolina Nery Wittmaack
Monica Carolina Nery Wittmaack
MCMaria Eduarda Bastos Andrade Moutinho Conceição
Maria Eduarda Bastos Andrade Moutinho Conceição
MVMaría Camila Maldonado Vera
María Camila Maldonado Vera
RFRachel Inamassu Faccini
Rachel Inamassu Faccini
GSGuilherme Sembenelli
Guilherme Sembenelli
PMPaola Moraes
Paola Moraes
The aim of this randomized study was to compare the complications and perioperative outcome of three different techniques of laparoscopic cholecystectomy (LC). Changes in the liver function test after LC techniques were investigated. Also, we compared the degree of postoperative adhesions and histopathological changes of the liver bed.

23 January 2020 in Acta Scientiae Veterinariae
Verified
Journal Article
Open access
PDF file
GSGuilherme Sembenelli
Guilherme Sembenelli
JJJose Sergio Costa Junior
Jose Sergio Costa Junior
MWMonica Carolina Nery Wittmaack
Monica Carolina Nery Wittmaack
GMGabriel Luiz Montanhim
Gabriel Luiz Montanhim
LDLuis Gustavo Gosuen Gonçalves Dias
Luis Gustavo Gosuen Gonçalves Dias
PMPaola De Castro Moraes
Paola De Castro Moraes
Background: Ectopic ureter is a congenital anomaly in which the final segment of one or both ureteral orifices is located distal to the bladder trigone. It may be classified as intra- or extramural. Surgical treatment of ectopic ureters in dogs is recommended and the approach varies with the classification. In the postoperative period, complications are common. When stenosis of the new ureteral ostium occurs, immediate repeated surgery is recommended. This study aimed at using the double J catheter placement following neoureterostomy to treat urethral obstruction secondary to the surgical treatment of an intramural ectopic ureter in a dog. Case: An 8-month-old female French bulldog with dysuria and urinary incontinence was seen at a private veterinary hospital in Jaboticabal, São Paulo. The patient had previously been diagnosed with an intramural ectopic ureter on the right side following imaging tests (ultrasound, computed tomography, and abdominal radiography, excretory urography) and had undergone neoureterostomy and closure of the intramural pathway approximately a year ago. Ultrasonographic examination showed dilation of the caudal portion of the ureter and hydroureter, which was suggestive of right ureteral stenosis. Computed tomography was also performed to evaluate the kidneys, ureters, and bladder; an increase in the diameter of the right ureter in its middle portion and close to the bladder triangle was observed. A new surgical intervention was indicated and performed. The ureteral route was identified in a region of the bladder trigone, incised, and probed with a urethral probe No. 04. The intramural course in the proximal urethra was identified and probed with a 16G epidural catheter. It was necessary to perform a neoureterostomy. A longitudinal incision (spatulation) of approximately 5 mm was made in the distal portion of the right ureter to increase the circumference of the anastomosis. The double J 4.7 French (Fr) catheter was inserted through the new ureter ostium into the bladder and advanced into the right kidney in a retrograde manner. Once the proximal end of the double J catheter reached the renal pelvis, the guidewire was withdrawn slowly to allow the catheter to bend in the areas of the renal pelvis and the trigone. The distal end of the double J catheter that extended beyond the bladder lumen was sectioned for better bladder closure. The patient underwent clinical evaluation and laboratory tests (complete blood count and serum creatinine concentration, urine test with bacteriological culture and susceptibility test) 2 weeks after the procedure and, subsequently, every 3 months. Ultrasonography of the urinary tract was performed every 2 months. Discussion: We used a double J catheter in the patient due to a previous obstruction of the ureter ostium after the first surgical procedure. In this way, complications such as postoperative obstructions due to ureteritis and ureteral constriction were avoided and ureteral anastomosis was facilitated. It has been reported that animals subjected to ureteral stent placement have high incidences of dysuria and urinary tract infection, and low incidences of stent migration and occlusion. In this case, no signs of occlusion or obstruction of the implant were identified, but there was a recurrence of urinary tract infections. These frequently cause urethral obstruction associated with the healing of the new ureteral ostium. Patient follow-up and findings associated with the long-term insertion of the double J catheter provide support for the clinical relevance of the present report.

1 October 2022 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Verified
Journal Article
Open access
GSG. Sembenelli
G. Sembenelli
GSG.V. Souza
G.V. Souza
MWM.C.N. Wittmaack
M.C.N. Wittmaack
ASA.C. Shimano
A.C. Shimano
TRThiago ANDRÉ Salvitti de Sá Rocha
Thiago ANDRÉ Salvitti de Sá Rocha
LDL.G.G.G. Dias
L.G.G.G. Dias
The aim of this study was to develop a modified tibial plateau leveling osteotomy (TPLO) plate and to compare its biomechanical properties with a locking compression plate (LCP) and plate-rod constructs for the stabilization of experimentally induced gap fractures in canine synthetic tibias. The tibial models were assigned to either repair with a modified TPLO plate (Group 1), locking compression plate construct (Group 2), or plate-rod construct (Group 3). The specimens were loaded to failure in axial compression, three-point mediolateral and craniocaudal bending. There was no statistical difference between the three groups regarding stiffness (N/mm) and deformation (mm) in axial compression. The modified TPLO plate achieved load to failure similar to the plate-rod construct in craniocaudal bending. There was no significant difference between groups on mediolateral bending tests regarding load to failure and deformation. Furthermore, there was no significant difference in stiffness between groups 1 and 2. In conclusion, the modified TPLO plate had similar mechanical properties to LCP and plate-rod construct in the axial compression and bending tests. Nonetheless, clinical studies with a large population of dogs are required to determine the value of this new implant in proximal tibial fracture repair.

1 January 2023 in Ciência Rural
Verified
Journal Article
Open access
MWMonica Carolina Nery Wittmaack
Monica Carolina Nery Wittmaack
GSGuilherme Sembenelli
Guilherme Sembenelli
MCMaria Eduarda Bastos Andrade Moutinho da Conceição
Maria Eduarda Bastos Andrade Moutinho da Conceição
GMGabriel Luiz Montanhim
Gabriel Luiz Montanhim
RCRoberta Martins Crivellaro
Roberta Martins Crivellaro
PMPaola Moraes
Paola Moraes
Thoracoscopy is replacing open lung biopsies because it is less invasive, usually the technique is done using three portals and intracorporeal suture technique. This study described the feasibility and efficacy of a novel pre tied loop ligature and to propose a thoracoscopic access strategy with two portals to perform lung biopsy in patients under 5 kg. Ten rabbits were positioned in dorsal recumbency. Total thoracoscopic lung biopsy was performed using a combined transdiaphragmatic approach and a right intercostal approach. A pre tied loop ligature was placed to perform a caudal lung lobe biopsy. Insufflation of the thoracic cavity was not performed. The total surgery time was 41.4 ± 14.5 min. The procedure was carried out free of complications that prevented slippage or tightening the knot or that made it come loose after the lung biopsy; there was no serious complication during the surgical procedure. The samples obtained averaged 1x0.64x0.45 cm (Length, Width, Depth) and were considered satisfactory according to the histopathologic evaluation. Thorax radiographs taken before and after the surgeries were compared and showed no pneumothorax or hemothorax. Necropsy confirmed no knot failure occurred at the biopsy site. The use of the novel pre tied loop ligature is a safe and effective technique, avoiding problems with the limited size of the thoracic cavity in small patients.