Junying Xia

Junying Xia

Auto-generated profile, based on publicly available information

Junying Xia

Shanghai Hynitron Technology Company Ltd., Xian, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in SoftwareX
Verified
Journal Article
Open access
BLBenyuan Liu
Benyuan Liu
BYBin Yang
Bin Yang
CXCanhua Xu
Canhua Xu
JXJunying Xia
Junying Xia
MDMeng Dai
Meng Dai
FFFeng Fu
Feng Fu

15 July 2019 in IEEE Access
Verified
Journal Article
Open access
HMHang Ma
Hang Ma
HLHaoting Li
Haoting Li
XLXuechao Liu
Xuechao Liu
WLWeichen Li
Weichen Li
JXJunying Xia
Junying Xia
FFFeng Fu
Feng Fu
Electrical impedance tomography (EIT) is a promising medical technique for monitoring brain injury through the reflection of electrical impedance changes in internal brain tissues. However, the contact impedances at the electrode-scalp interfaces can still notably affect the EIT accuracy. Hence, we propose a method for real-time monitoring the multi-channel contact impedances of cerebral EIT using a reference electrode attached close to the head vertex. This method allows to approximate inter-channel differences and changes over time of multi-channel contact impedances. The experimental results on 36 volunteers show that the maximum relative inter-channel difference obtained from 16 disposable surface electrodes reaches 18.7%, and the maximum relative change over time reaches 19.2%. The proposed method can assist clinicians in real-time monitoring of contact conditions from the multiple electrode-scalp interfaces during the clinical application of the cerebral EIT.

3 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Lin YangLin Yang
Lin Yang
Meng DaiMeng Dai
Meng Dai
HWHang Wang
Hang Wang
XCXinsheng Cao
Xinsheng Cao
SLShiqin Li
Shiqin Li
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
Individualized lung-protective ventilation strategy is essential for patients with COVID-19. In this study, a wireless, low-power, and miniaturized electrical impedance tomography (EIT) system was developed for remote and long-term monitoring of lung ventilation for patients with COVID-19 in the isolation ward of ICU. A new strategy of combining filtering and improved voltage-controlled current was employed to design the current source for a simplified system structure, and a new differential receiver circuit consisting of a buffer amplification and a differential amplification was proposed to design the voltage measurement unit for high precision. Moreover, a Bluetooth interface was adopted for wireless data transmission, and components characterized by low power consumption were selected to minimize the system power consumption. The proposed EIT system occupies a total size of $6.5\times 4.5\times0.6$ cm 3 and can work stably within 25 m from the wireless terminal installed with host EIT software. The system has a signal-to-noise of 70 dB at 50 kHz, stability of 0.1% relative change, and power consumption of 114 mW, as tested with a resistor phantom. Furthermore, a comparison between the proposed system and a commercial ICU EIT device was conducted on nine healthy volunteers for ventilation monitoring. The correlation between lung volume and relative impedance changes was higher than 0.9 for both EIT systems ( $p < 0.001$ ). The analysis of the corresponding EIT images revealed that both systems delivered comparable images in terms of linearity, repeatability, and regional ventilation distribution. The test and experimental results suggested that the proposed system could conveniently provide reliable data acquisition (DAQ) for remote and long-term lung ventilation monitoring.