Sergey Drobinsky

Sergey Drobinsky

Auto-generated profile, based on publicly available information

Sergey Drobinsky

Chair of Medical Engineering, RWTH Aachen University, Aachen, Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
YLYao Li
Yao Li
SDSergey Drobinsky
Sergey Drobinsky
PBPaulina Becker
Paulina Becker
KXKunpeng Xie
Kunpeng Xie
MLMyriam Lipprandt
Myriam Lipprandt
BPBehrus Puladi
Behrus Puladi
Conventional navigation systems (CNS) in surgery require strong spatial cognitive abilities and hand-eye coordination. Augmented Reality Navigation Systems (ARNS) provide 3D guidance and may overcome these challenges, but their accuracy and efficiency compared to CNS have not been systematically evaluated. In this randomized crossover study with 36 participants from different professional backgrounds (surgeons, students, engineers), drilling accuracy, time and perceived workload were evaluated using ARNS and CNS. For the first time, this study provides compelling evidence that ARNS and CNS have comparable accuracy in translational error. Differences in angle and depth error with ARNS were likely due to limited stereoscopic vision, hardware limitations, and design. Despite this, ARNS was preferred by most participants, including surgeons with prior navigation experience, and demonstrated a significantly better overall user experience. Depending on accuracy requirements, ARNS could serve as a viable alternative to CNS for guided drilling, with potential for future optimization.

16 July 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
SDSergey Drobinsky
Sergey Drobinsky
MFMatías de la Fuente
Matías de la Fuente
BPBehrus Puladi
Behrus Puladi
KRKlaus Radermacher
Klaus Radermacher
Purpose: In bone surgery specialties, like orthopedics, neurosurgery, and oral and maxillofacial surgery patient safety and treatment success depends on the accurate implementation of computer-based surgical plans. Unintentional plan deviations can result in long-term functional damage to the patient. With on-site teleoperation, the surgeon operates a slave robot with a physically-decoupled master device, while being directly present at the operation site. This allows the surgeon to perform surgical tasks with robotic accuracy, while always remaining in the control loop. Methods: In this study the master- and slave-side accuracy of an on-site teleoperated miniature cooperative robot (minaroHD) is evaluated. Master-side accuracy is investigated in a user study regarding scale factor, target feed rate, movement direction and haptic guidance stiffness. Scale factors are chosen to correspond to primarily finger, hand, and arm movements. Slave-side accuracy is investigated in autonomous milling trials regarding stepover, feed rate, movement direction, and material density. Results: Master-side user input errors increase with increasing target feed rate and scale factor, and decrease with increasing haptic guidance stiffness. Resulting slave-side errors decrease with increasing scale factor and are < 0.07 mm for optimal guidance parameters. Slave-side robot position errors correlate with the feed rate but show little correlation with stepover distance. For optimal milling parameters, the 95th percentile of tracked slave-side position error is 0.086 mm with a maximal error of 0.16 mm. Conclusion: For optimal guidance and milling parameters, the combined error of 0.23 mm is in the range of the dura mater thickness (< 0.27 mm) or mandibular canal wall (~ 0.85 mm). This corresponds to safety margins in high-demand surgical procedures like craniotomies, laminectomies, or decortication of the jaw. However, for further clinical translation, the performance and usability of on-site teleoperated milling must be further evaluated for real-life clinical application examples with consideration of all error sources in a computer-assisted surgery workflow.

9 November 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
MVManuel Vossel
Manuel Vossel
LTLukas Theisgen
Lukas Theisgen
NWNoah Wickel
Noah Wickel
LPLovis Phlippen
Lovis Phlippen
RPRastislav Pjontek
Rastislav Pjontek
MFMatías de la Fuente
Matías de la Fuente
Purpose: Although the literature shows that robotic assistance can support the surgeon, robotic systems are not widely spread in clinics. They often incorporate large robotic arms adopted from the manufacturing industry, imposing safety hazards when in contact with the patient or surgical staff. We approached this limitation with a modular dual robot consisting of an ultra-lightweight carrier robot for rough prepositioning and small, highly dynamic, application-specific, interchangeable tooling robots. Methods: A formative usability study with N = 10 neurosurgeons was conducted using a prototype of a novel tooling robot for laminectomy to evaluate the system’s usability. The participants were asked to perform three experiments using the robotic system: (1) prepositioning with the carrier robot and milling into (2) a block phantom as well as (3) a spine model. Results: All neurosurgeons could perform a simulated laminectomy on a spine phantom using the robotic system. On average, they rated the usability of this first prototype already between good and excellent (SUS-Score above 75%). Eight out of the ten participants preferred robotic-assisted milling over manual milling. For prepositioning, the developed haptic guidance showed significantly higher effectiveness and efficiency than visual navigation. Conclusion: The proposed dual robot system showed the potential to increase safety in the operating room because of the synergistic hands-on control and the ultra-lightweight design of the carrier robot. The modular design allows for easy adaptation to various surgical procedures. However, improvements are needed in the ergonomics of the tooling robot and the complexity of the virtual fixtures. The cooperative dual robot system can subsequently be tested in a cadaver laboratory and in vivo on animals.

5 September 2024 in medRxiv
Verified
Preprint
Open access
PDF file
PBPaulina Becker
Paulina Becker
YLYao Li
Yao Li
SDSergey Drobinsky
Sergey Drobinsky
JEJan Egger
Jan Egger
KXKunpeng Xie
Kunpeng Xie
BPBehrus Puladi
Behrus Puladi
The current gold standard of computer-assisted jaw reconstruction includes raising microvascular bone flaps with patient-specific 3D-printed cutting guides. The downsides of cutting guides are invasive fixation, periosteal denudation, preoperative lead time and missing intraoperative flexibility. This study aimed to investigate the feasibility and accuracy of a robot-assisted cutting method for raising iliac crest flaps compared to a conventional 3D-printed cutting guide. In a randomized crossover design, 40 participants raised flaps on pelvic models using conventional cutting guides and a robot-assisted cutting method. The accuracy was measured and compared regarding osteotomy angle deviation, Hausdorff Distance (HD) and Average Hausdorff Distance (AVD). Duration, workload and usability were further evaluated. The mean angular deviation for the robot-assisted cutting method was 1.9±1.1° (mean±sd) and for the 3D-printed cutting guide it was 4.7±2.9° (p<0.001). The HD resulted in a mean value of 1.5±0.6mm (robot) and 2.0±0.9mm (conventional) (p<0.001). For the AVD, this was 0.8±0.5mm (robot) and 0.8±0.4mm (conventional) (p=0.320). Collaborative robot-assisted cutting is an alternative to 3D-printed cutting guides in experimental static settings, achieving slot design benefits with less invasiveness and higher intraoperative flexibility. In the next step, the results should be tested in a dynamic environment with a moving phantom and on the cadaver.

1 August 2021 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SDSergey Drobinsky
Sergey Drobinsky
TLTill Lindeman
Till Lindeman
PSPhilipp Schleer
Philipp Schleer
KRKlaus Radermacher
Klaus Radermacher
Manual control of surgical instruments represents a sensorimotor control task with at least 3-6 degrees of freedom (DoF). The impact of haptic guidance on volumetric navigation tasks, such as milling of planned volumes for prosthesis fits or preserving sensitive tissues, is investigated. Interaction centered studies are performed to evaluate the usability of the assistance modes for navigation within a volume, along the surface of a volume and around forbidden regions. Results show that haptic assistance can reduce the number of constraint violations, if the virtual stiffness is high enough. However, haptic assistance also can increase error rates when counterforces are close to the absolute perception threshold, as a false sense of security can arise. For navigation along complex surfaces bilateral haptic constraints should be preferred, while unilateral constraints are sufficient for simple geometries. This study complements previous publications as a basis for a flexible rule-based selection or adaptation of modular haptic assistance systems.