Kunpeng Xie

Mr. Kunpeng Xie

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2024 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
IMIla Motmaen
Ila Motmaen
KXKunpeng Xie
Kunpeng Xie
LSLeon Schönbrunn
Leon Schönbrunn
JBJeff Berens
Jeff Berens
KGKim Grunert
Kim Grunert
BPBehrus Puladi
Behrus Puladi
Objectives: Tooth extraction is one of the most frequently performed medical procedures. The indication is based on the combination of clinical and radiological examination and individual patient parameters and should be made with great care. However, determining whether a tooth should be extracted is not always a straightforward decision. Moreover, visual and cognitive pitfalls in the analysis of radiographs may lead to incorrect decisions. Artificial intelligence (AI) could be used as a decision support tool to provide a score of tooth extractability. Material and methods: Using 26,956 single teeth images from 1,184 panoramic radiographs (PANs), we trained a ResNet50 network to classify teeth as either extraction-worthy or preservable. For this purpose, teeth were cropped with different margins from PANs and annotated. The usefulness of the AI-based classification as well that of dentists was evaluated on a test dataset. In addition, the explainability of the best AI model was visualized via a class activation mapping using CAMERAS. Results: The ROC-AUC for the best AI model to discriminate teeth worthy of preservation was 0.901 with 2% margin on dental images. In contrast, the average ROC-AUC for dentists was only 0.797. With a 19.1% tooth extractions prevalence, the AI model's PR-AUC was 0.749, while the dentist evaluation only reached 0.589. Conclusion: AI models outperform dentists/specialists in predicting tooth extraction based solely on X-ray images, while the AI performance improves with increasing contextual information. Clinical relevance: AI could help monitor at-risk teeth and reduce errors in indications for extractions.

10 November 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
YLYao Li
Yao Li
SDSergey Drobinsky
Sergey Drobinsky
PBPaulina Becker
Paulina Becker
KXKunpeng Xie
Kunpeng Xie
MLMyriam Lipprandt
Myriam Lipprandt
BPBehrus Puladi
Behrus Puladi
Conventional navigation systems (CNS) in surgery require strong spatial cognitive abilities and hand-eye coordination. Augmented Reality Navigation Systems (ARNS) provide 3D guidance and may overcome these challenges, but their accuracy and efficiency compared to CNS have not been systematically evaluated. In this randomized crossover study with 36 participants from different professional backgrounds (surgeons, students, engineers), drilling accuracy, time and perceived workload were evaluated using ARNS and CNS. For the first time, this study provides compelling evidence that ARNS and CNS have comparable accuracy in translational error. Differences in angle and depth error with ARNS were likely due to limited stereoscopic vision, hardware limitations, and design. Despite this, ARNS was preferred by most participants, including surgeons with prior navigation experience, and demonstrated a significantly better overall user experience. Depending on accuracy requirements, ARNS could serve as a viable alternative to CNS for guided drilling, with potential for future optimization.

26 February 2024 in Systematic Reviews
Verified
Journal Article
Open access
PDF file
JMJasper J.E. Moors
Jasper J.E. Moors
ZXZhibin Xu
Zhibin Xu
KXKunpeng Xie
Kunpeng Xie
ARAshkan Rashad
Ashkan Rashad
JEJan Egger
Jan Egger
BPBehrus Puladi
Behrus Puladi
Background: The radial forearm free flap (RFFF) serves as a workhorse for a variety of reconstructions. Although there are a variety of surgical techniques for donor site closure after RFFF raising, the most common techniques are closure using a split-thickness skin graft (STSG) or a full-thickness skin graft (FTSG). The closure can result in wound complications and function and aesthetic compromise of the forearm and hand. The aim of the planned systematic review and meta-analysis is to compare the wound-related, function-related and aesthetics-related outcome associated with full-thickness skin grafts (FTSG) and split-thickness skin grafts (STSG) in radial forearm free flap (RFFF) donor site closure. Methods: A systematic review and meta-analysis will be conducted. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines will be followed. Electronic databases and platforms (PubMed, Embase, Scopus, Web of Science, Cochrane Central Register of Controlled Trials (CENTRAL), China National Knowledge Infrastructure (CNKI)) and clinical trial registries (ClinicalTrials.gov, the German Clinical Trials Register, the ISRCTN registry, the International Clinical Trials Registry Platform) will be searched using predefined search terms until 15 January 2024. A rerun of the search will be carried out within 12 months before publication of the review. Eligible studies should report on the occurrence of donor site complications after raising an RFFF and closure of the defect. Included closure techniques are techniques that use full-thickness skin grafts and split-thickness skin grafts. Excluded techniques for closure are primary wound closure without the use of skin graft. Outcomes are considered wound-, functional-, and aesthetics-related. Studies that will be included are randomized controlled trials (RCTs) and prospective and retrospective comparative cohort studies. Case-control studies, studies without a control group, animal studies and cadaveric studies will be excluded. Screening will be performed in a blinded fashion by two reviewers per study. A third reviewer resolves discrepancies. The risk of bias in the original studies will be assessed using the ROBINS-I and RoB 2 tools. Data synthesis will be done using Review Manager (RevMan) 5.4.1. If appropriate, a meta-analysis will be conducted. Between-study variability will be assessed using the I2 index. If necessary, R will be used. The quality of evidence for outcomes will eventually be assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Discussion: This study's findings may help us understand both closure techniques' complication rates and may have important implications for developing future guidelines for RFFF donor site management. If available data is limited and several questions remain unanswered, additional comparative studies will be needed. Systematic review registration: The protocol was developed in line with the PRISMA-P extension for protocols and was registered with the International Prospective Register of Systematic Reviews (PROSPERO) on 17 September 2023 (registration number CRD42023351903).

27 May 2025 in Systematic Reviews
Verified
Journal Article
Open access
PDF file
JMJasper J. E. Moors
Jasper J. E. Moors
ZXZhibin Xu
Zhibin Xu
KXKunpeng Xie
Kunpeng Xie
ARAshkan Rashad
Ashkan Rashad
OVOliver Vladu
Oliver Vladu
BPBehrus Puladi
Behrus Puladi
Background: The radial forearm free flap (RFFF) is widely used in microvascular reconstructions. However, donor site morbidity remains a concern, with complications such as wound healing issues, functional impairments, and aesthetic concerns. While both full-thickness skin grafts (FTSG) and split-thickness skin grafts (STSG) are commonly used for donor site closure, there is insufficient evidence to determine which technique leads to fewer complications. This study aims to systematically compare FTSG and STSG in RFFF donor site closure. Methods: We searched six databases and four clinical trial registries up to 1 March 2025. We focused on studies comparing FTSG and STSG. Primary outcome was the incidence of wound complications. Secondary outcomes included functional and aesthetic impairment. Risk of bias was assessed using the Risk Of Bias In Non-Randomized Studies—of Interventions (ROBINS-I) and quality of the evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Results: Fifteen studies were analyzed, involving 933 donor site closures. No RCTs met our inclusion criteria. Meta-analysis comparing FTSG versus STSG revealed no significant differences in major wound complications (RR 0.43; 95% CI 0.11 to 1.70; p = 0.23) and minor wound healing complications (RR 0.83; 95% CI 0.60 to 1.13; p = 0.23), with the evidence graded as low to very low certainty. Conclusion: Current evidence does not conclusively favor either FTSG or STSG for radial forearm free flap donor site closure regarding wound, functional, or aesthetic outcomes. Future well-designed RCTs are needed to provide higher-quality evidence to guide clinical decision-making. Until more robust evidence becomes available, the optimal skin graft choice should be guided by patient-specific factors, surgical considerations, and donor site characteristics. Systematic review registration: PROSPERO CRD42023351903.

17 October 2025 in Expert Systems with Applications
Verified
Journal Article
Open access
KXKunpeng Xie
Kunpeng Xie
LGLennart Johannes Gruber
Lennart Johannes Gruber
MCMartin Crampen
Martin Crampen
YLYao Li
Yao Li
AFAndré Ferreira
André Ferreira
BPBehrus Puladi
Behrus Puladi

21 October 2025 in Current Oncology
Verified
Journal Article
Open access
PDF file
FOFelix Barajas Ordonez
Felix Barajas Ordonez
KXKunpeng Xie
Kunpeng Xie
AFAndré Ferreira
André Ferreira
RSRobert Siepmann
Robert Siepmann
NCNajiba Chargi
Najiba Chargi
BPBehrus Puladi
Behrus Puladi
Background: Sarcopenia assessed by skeletal muscle area (SMA) at the third lumbar vertebra (L3) is an established prognostic marker in many malignancies, including head and neck cancer (HNC). However, in HNC, L3 is rarely assessed. The prognostic value of myosteatosis, measured by skeletal muscle radiation attenuation (SMRA) remains largely unexplored. This study evaluated both muscle metrics at the third cervical vertebra (C3) for locoregional control (LRC) and overall survival (OS) in HNC. Methods: SMA and SMRA at C3 were quantified in CT scans of 904 HNC cases by a deep learning-based segmentation pipeline with manual verification. Cox proportional hazards models assessed associations with LRC and OS. Results: Median SMA was 36.64 cm2 (IQR: 30.12–42.44). Median SMRA was 50.77 HU (IQR: 43.04–57.39). In multivariable analysis, lower SMA (HR 1.85, 95% CI: 1.19–2.88, p ≤ 0.001) and lower SMRA (HR 1.76, 95% CI: 1.22–2.54, p < 0.001) were associated with lower LRC. For OS, lower SMA (HR 1.53, 95% CI:1.06–2.20, p = 0.02) and lower SMRA (HR 2.13, 95% CI: 1.58–2.88, p < 0.001) were associated with a worse outcome in multivariable analysis. Conclusions: Both SMRA and SMA assessed at C3 correlate with worse LRC and OS in HNC.