Bryan R. Schlink

Bryan R. Schlink

Auto-generated profile, based on publicly available information

Bryan R. Schlink

Battelle Memorial Institute

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2018 in HIP International
Verified
Journal Article
Open access
PDF file
Gary FarkasGary Farkas
Gary Farkas
BSBryan R Schlink
Bryan R Schlink
LFLouis F Fogg
Louis F Fogg
KFKharma C Foucher
Kharma C Foucher
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer
NSNajia Shakoor
Najia Shakoor
Little is known about the loading patterns in unilateral hip osteoarthritis (OA) and their relationship to radiographic severity and pain. We aimed to examine the loading patterns at the hips of those with unilateral symptomatic hip OA and identify associations between radiographic severity and pain with loading alterations. 61 subjects with symptomatic unilateral hip OA underwent gait analyses and evaluation for radiographic severity (Kellgren-Lawrence [KL]-grade) and pain (visual analogue scale) at bilateral hips. Hip OA subjects had greater range of motion and higher hip flexion, adduction, internal and external rotation moments at the contralateral, asymptomatic hip compared to the ipsilateral hip (p < 0.05). Correlations were noted between increasing KL-grade and increasing asymmetry of contralateral to ipsilateral hip loading (p < 0.05). There were no relationships with pain and loading asymmetry. Unilateral symptomatic hip OA subjects demonstrate asymmetry in loading between the hips, with relatively greater loads at the contralateral hip. These loading asymmetries were directly related to the radiographic severity of symptomatic hip OA and not with pain. Additional research is needed to determine the role of gait asymmetries in disease progression.

3 June 2020 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
BSBryan R. Schlink
Bryan R. Schlink
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
DFDaniel Ferris
Daniel Ferris
Objective: High-density electromyography (EMG) is useful for studying changes in myoelectrical activity within a muscle during human movement but is prone to motion artifacts during locomotion. We compared canonical correlation analysis and principal component analysis methods for signal decomposition and component filtering with a traditional EMG high-pass filtering approach to quantify their relative performance at removing motion artifacts from high-density EMG of the gastrocnemius and tibialis anterior muscles during human walking and running. Results: Canonical correlation analysis filtering provided a greater reduction in signal content at frequency bands associated with motion artifacts than either traditional high-pass filtering or principal component analysis filtering. Canonical correlation analysis filtering also minimized signal reduction at frequency bands expected to consist of true myoelectric signal. Conclusions: Canonical correlation analysis filtering appears to outperform a standard high-pass filter and principal component analysis filter in cleaning high-density EMG collected during fast walking or running.

16 June 2017 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
BSBryan R. Schlink
Bryan R. Schlink
SPSteven Peterson
Steven Peterson
WHW. D. Hairston
W. D. Hairston
PKPeter König
Peter König
SKScott E. Kerick
Scott E. Kerick
DFDaniel Ferris
Daniel Ferris
Mobile electroencephalography (EEG) is a very useful tool to investigate the physiological basis of cognition under real-world conditions. However, as we move experimentation into less-constrained environments, the influence of state changes increases. The influence of stress on cortical activity and cognition is an important example. Monitoring of modulation of cortical activity by EEG measurements is a promising tool for assessing acute stress. In this study, we test this hypothesis and combine EEG with independent component analysis and source localization to identify cortical differences between a control condition and a stressful condition. Subjects performed a stationary shooting task using an airsoft rifle with and without the threat of an experimenter firing a different airsoft rifle in their direction. We observed significantly higher skin conductance responses and salivary cortisol levels (p < 0.05 for both) during the stressful conditions, indicating that we had successfully induced an adequate level of acute stress. We located independent components in five regions throughout the cortex, most notably in the dorsolateral prefrontal cortex, a region previously shown to be affected by increased levels of stress. This area showed a significant decrease in spectral power in the theta and alpha bands less than a second after the subjects pulled the trigger. Overall, our results suggest that EEG with independent component analysis and source localization has the potential of monitoring acute stress in real-world environments.

5 December 2020 in Physiological Reports
Verified
Journal Article
Open access
PDF file
BSBryan R. Schlink
Bryan R. Schlink
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
DFDaniel Ferris
Daniel Ferris
Dynamic high‐density electromyography (EMG) recordings revealed heterogeneous spatial myoelectric patterns in lower limb muscles during locomotion. Spatial EMG activity became more localized as locom...

1 May 2021 in Journal of Neurophysiology
Verified
Journal Article
Open access
PDF file
BSBryan R. Schlink
Bryan R. Schlink
Andrew D. NordinAndrew D. Nordin
Andrew D. Nordin
CBChristina N. Brooks
Christina N. Brooks
DFDaniel P. Ferris
Daniel P. Ferris
This research investigates the effects of muscle fatigue on spatial myoelectric patterns in the lower limb during locomotion. Both spatial and frequency aspects of neuromuscular recruitment in the medial gastrocnemius change in response to fatigue, resulting in altered myoelectric patterns during walking and running. These data may help us better understand the adaptations that occur in lower limb muscles to avoid overuse injuries caused by fatigue.

1 August 2024 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
NTNicholas Tacca
Nicholas Tacca
IBIan Baumgart
Ian Baumgart
BSBryan R Schlink
Bryan R Schlink
AKAshwini Kamath
Ashwini Kamath
CDCollin Dunlap
Collin Dunlap
EMEric C Meyers
Eric C Meyers
Objective. Non-invasive, high-density electromyography (HD-EMG) has emerged as a useful tool to collect a range of neurophysiological motor information. Recent studies have demonstrated changes in EMG features that occur after stroke, which correlate with functional ability, highlighting their potential use as biomarkers. However, previous studies have largely explored these EMG features in isolation with individual electrodes to assess gross movements, limiting their potential clinical utility. This study aims to predict hand function of stroke survivors by combining interpretable features extracted from a wearable HD-EMG forearm sleeve. Approach. Here, able-bodied (N = 7) and chronic stroke subjects (N = 7) performed 12 functional hand and wrist movements while HD-EMG was recorded using a wearable sleeve. A variety of HD-EMG features, or views, were decomposed to assess alterations in motor coordination. Main Results. Stroke subjects, on average, had higher co-contraction and reduced muscle coupling when attempting to open their hand and actuate their thumb. Additionally, muscle synergies decomposed in the stroke population were relatively preserved, with a large spatial overlap in composition of matched synergies. Alterations in synergy composition demonstrated reduced coupling between digit extensors and muscles that actuate the thumb, as well as an increase in flexor activity in the stroke group. Average synergy activations during movements revealed differences in coordination, highlighting overactivation of antagonist muscles and compensatory strategies. When combining co-contraction and muscle synergy features, the first principal component was strongly correlated with upper-extremity Fugl Meyer hand sub-score of stroke participants (R 2 = 0.86). Principal component embeddings of individual features revealed interpretable measures of motor coordination and muscle coupling alterations. Significance. These results demonstrate the feasibility of predicting motor function through features decomposed from a wearable HD-EMG sleeve, which could be leveraged to improve stroke research and clinical care.