26 December 2021 in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
NINational Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
VTVishwaniketan Institute of Management Entrepreneurship and Engineering Technology
Vishwaniketan Institute of Management Entrepreneurship and Engineering Technology
Purpose. A review of the current literature, regarding the existing approaches used to estimate the lightning perfor-mance of overhead power lines, was performed. A review of available lightning activity data over India was also per-formed. Methodology. The electro-geometrical model was chosen to analyze the lightning performance of overhead power lines. International normative documents and national standard were used to highlight the main parameters that should to be paid main attention to when estimating lightning performance of overhead power lines. Results. Presently, approaches from IEEE and CIGRE guides can be used for analysis of statistical distributions of lightning current pa-rameters. Further studies are required on thunderstorm days, ground flash density and current parameters statistical dis-tributions for different locations, which will be supportive in performing analysis for Indian power lines. Originality. To graphically analyze the shielding failure mechanism with a help of electro-geometric model, the sketch of real 220 kV double-circuit transmission line tower was used. Using electro-geometric model it was graphically shown how downward lightning leader that propagate from thunderstorm cloud toward ground can finish its path on the overhead shield wire, phase conductor or ground plane. Practical value. Available data on lightning activity over different parts of India are still not enough complete. It is of great importance to obtain reliable statistical data on thunderstorm characteristics in the area of the studied power line route. Measurement techniques based on satellites have limitations in obtaining ground flash density values. Thus, for India there is a need in development of modern lightning detection networks and related studies on lightning characteristics. Conclusions. Future efforts should be focused on obtaining not only the positions and number of lightning strikes to the overhead power line, and calculation of lightning flashover rate parameters, but also the statistical distributions of lightning current values and related overvoltage parameters at the overhead wires and different phase conductors. References 21, figures 4.
29 July 2021 in Electrical Engineering & Electromechanics
Purpose. Determination in the analytical form of the maximum limiting influence of the non-identity of the capacitive elements of the high-voltage arm on the amplitude-frequency characteristic and phase-frequency characteristic of the voltage divider with parallel-series connection of R-, C-elements of the high-voltage arm. Methodology. Based on the previously developed theory of broadband voltage dividers with parallel-series connection of R-, C-elements, analytical expressions for amplitude-frequency and phase-frequency characteristics of the voltage divider are obtained and investigated taking into account the limit case of non-identical capacitive elements of high-voltage arm. Results. The nature of the dependencies of the frequency characteristics of the broadband voltage divider on the value of the tolerance of the capacitive elements of the high-voltage arm, the division factor of the voltage divider in a wide range of frequency changes is determined. Simplified approximating expressions for the maximum values of frequency characteristics of the voltage divider are proposed and their error is determined. Originality. For the first time in the analytical form the limiting influence of non-identity of capacitive elements of a high-voltage arm of a voltage divider on its frequency characteristics is considered. A mathematical model of this influence is constructed and the limit values of frequency characteristics of the voltage divider are determined. Practical value. It is recommended to introduce into the normative documentation of broadband voltage dividers the corrected value of the division factor, which allows to significantly reduce the deviation of the actual value of the division factor of the voltage divider from the normalized value in a wide range of frequency changes.
23 April 2023 in Electrical Engineering & Electromechanics
Purpose. Determination in the analytical form of the maximum limiting influence of the non-identity of the resistive elements of the high-voltage arm on the amplitude-frequency characteristic and phase-frequency characteristic of the voltage divider with parallel-series connection of R-, C-elements of the high-voltage arm. Methodology. Based on the previously developed theory of broadband voltage dividers with parallel-series connection of R‑, C-elements, analytical expressions for amplitude-frequency and phase-frequency characteristics of the voltage divider are obtained and investigated taking into account the limit case of non-identical resistive elements of high-voltage arm. Results. The nature of the dependencies of the frequency characteristics of the broadband voltage divider on the value of the tolerance of the resistive elements of the high-voltage arm, the division factor of the voltage divider in a wide range of frequency changes are determined. Simplified approximating expressions for the maximum values of frequency characteristics of the voltage divider are proposed and their error is determined. Originality. For the first time in the analytical form the limiting influence of non-identity of resistive elements of a high-voltage arm of a voltage divider on its frequency characteristics is considered. A mathematical model of this influence is constructed and the limit values of frequency characteristics of the voltage divider are determined. Practical value. It is recommended to introduce into the normative documentation of broadband voltage dividers the corrected value of the division factor, which allows to significantly reduce the deviation of the actual value of the division factor of the voltage divider from the normalized value in a wide range of frequency changes.