26 December 2021 in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
NINational Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
VTVishwaniketan Institute of Management Entrepreneurship and Engineering Technology
Vishwaniketan Institute of Management Entrepreneurship and Engineering Technology
Purpose. A review of the current literature, regarding the existing approaches used to estimate the lightning perfor-mance of overhead power lines, was performed. A review of available lightning activity data over India was also per-formed. Methodology. The electro-geometrical model was chosen to analyze the lightning performance of overhead power lines. International normative documents and national standard were used to highlight the main parameters that should to be paid main attention to when estimating lightning performance of overhead power lines. Results. Presently, approaches from IEEE and CIGRE guides can be used for analysis of statistical distributions of lightning current pa-rameters. Further studies are required on thunderstorm days, ground flash density and current parameters statistical dis-tributions for different locations, which will be supportive in performing analysis for Indian power lines. Originality. To graphically analyze the shielding failure mechanism with a help of electro-geometric model, the sketch of real 220 kV double-circuit transmission line tower was used. Using electro-geometric model it was graphically shown how downward lightning leader that propagate from thunderstorm cloud toward ground can finish its path on the overhead shield wire, phase conductor or ground plane. Practical value. Available data on lightning activity over different parts of India are still not enough complete. It is of great importance to obtain reliable statistical data on thunderstorm characteristics in the area of the studied power line route. Measurement techniques based on satellites have limitations in obtaining ground flash density values. Thus, for India there is a need in development of modern lightning detection networks and related studies on lightning characteristics. Conclusions. Future efforts should be focused on obtaining not only the positions and number of lightning strikes to the overhead power line, and calculation of lightning flashover rate parameters, but also the statistical distributions of lightning current values and related overvoltage parameters at the overhead wires and different phase conductors. References 21, figures 4.
29 July 2021 in Electrical Engineering & Electromechanics
Purpose. Determination in the analytical form of the maximum limiting influence of the non-identity of the capacitive elements of the high-voltage arm on the amplitude-frequency characteristic and phase-frequency characteristic of the voltage divider with parallel-series connection of R-, C-elements of the high-voltage arm. Methodology. Based on the previously developed theory of broadband voltage dividers with parallel-series connection of R-, C-elements, analytical expressions for amplitude-frequency and phase-frequency characteristics of the voltage divider are obtained and investigated taking into account the limit case of non-identical capacitive elements of high-voltage arm. Results. The nature of the dependencies of the frequency characteristics of the broadband voltage divider on the value of the tolerance of the capacitive elements of the high-voltage arm, the division factor of the voltage divider in a wide range of frequency changes is determined. Simplified approximating expressions for the maximum values of frequency characteristics of the voltage divider are proposed and their error is determined. Originality. For the first time in the analytical form the limiting influence of non-identity of capacitive elements of a high-voltage arm of a voltage divider on its frequency characteristics is considered. A mathematical model of this influence is constructed and the limit values of frequency characteristics of the voltage divider are determined. Practical value. It is recommended to introduce into the normative documentation of broadband voltage dividers the corrected value of the division factor, which allows to significantly reduce the deviation of the actual value of the division factor of the voltage divider from the normalized value in a wide range of frequency changes.
23 April 2023 in Electrical Engineering & Electromechanics
Purpose. Determination in the analytical form of the maximum limiting influence of the non-identity of the resistive elements of the high-voltage arm on the amplitude-frequency characteristic and phase-frequency characteristic of the voltage divider with parallel-series connection of R-, C-elements of the high-voltage arm. Methodology. Based on the previously developed theory of broadband voltage dividers with parallel-series connection of R‑, C-elements, analytical expressions for amplitude-frequency and phase-frequency characteristics of the voltage divider are obtained and investigated taking into account the limit case of non-identical resistive elements of high-voltage arm. Results. The nature of the dependencies of the frequency characteristics of the broadband voltage divider on the value of the tolerance of the resistive elements of the high-voltage arm, the division factor of the voltage divider in a wide range of frequency changes are determined. Simplified approximating expressions for the maximum values of frequency characteristics of the voltage divider are proposed and their error is determined. Originality. For the first time in the analytical form the limiting influence of non-identity of resistive elements of a high-voltage arm of a voltage divider on its frequency characteristics is considered. A mathematical model of this influence is constructed and the limit values of frequency characteristics of the voltage divider are determined. Practical value. It is recommended to introduce into the normative documentation of broadband voltage dividers the corrected value of the division factor, which allows to significantly reduce the deviation of the actual value of the division factor of the voltage divider from the normalized value in a wide range of frequency changes.
2 January 2025 in Electrical Engineering & Electromechanics
Purpose. The aim of this work is the determination of the parasitic capacitance’s influence on the accuracy of scale transformation of high-voltage dividers. Analyzing the possibilities of reducing such influence is a pressing problem for high voltage measurement, especially at high frequency range of input voltage. Methodology. Mathematical modeling of the voltage divider equivalent circuit, considering parasitic capacitances and inductances has been performed in the QUCS circuit simulator software under sinusoidal alternating current conditions in the range from 100 Hz to 1 MHz. Using the FEMM software, the finite element method was used to simulate the density distribution of capacitive currents in the module with capacitance graded insulation of the high-voltage arm of the voltage divider. Results. The results of the calculations show that the percentage of parasitic capacitive currents decreases exponentially depending on the ratio of the outer radii of the shielding disks to the distance between them. However, even with the outer radii of the shielding disks of about 3 m, capacitive currents still make up about 1 % of the total current flowing in the measuring circuit of the voltage divider. Instead of increasing outer radii, it is proposed to use high-voltage capacitance graded insulation between the shielding disks. As a result, a stable error of large-scale voltage transformation was obtained when the values of parasitic capacitances change, and it is proposed to manufacture the high-voltage arm of the voltage divider from the same type of high-voltage modules. Originality. The results of modeling the dependence of the accuracy of the voltage divider scale transformation on the ratio of the structural elements geometric parameters of its high-voltage arm were obtained. The solution has been proposed that involves changing the design of the high-voltage arm of the voltage divider, which significantly reduces the dependence of its scale transformation error on significant changes in the parasitic capacitances of the structure components on grounded surfaces. Practical value. The results of mathematical modeling of the characteristics of the voltage divider high-voltage arm make it possible to design, for the purpose of serial production, the same type of high-voltage modules for assembling on-site broadband voltage dividers for any nominal voltage, which will have the possibility of integration into Smart Grid systems. References 23, tables 1, figures 8.
17 April 2023 in POWER ENGINEERING: economics, technique, ecology
This paper examines the risk of lightning stroke to overhead transmission line. The estimation procedure for the lightning performance of overhead power lines is based on the selected lightning attachment model, available lightning parameter statistics, the transmission tower design and voltage levels, type of overvoltage and other characteristics. In this paper the overview of factors affecting the estimation of lightning shielding performance of overhead transmission lines was performed. Among the factors that can affect the estimation accuracy, one can list insufficiently accurate data on the ground flash density in the area of interest and lack of complete data on statistical distribution of lightning current magnitudes. The paper shows that the influence of wind on the increase in the horizontal exposed distance of the phase conductor is not also taken into account. In this research traditional electro-geometric model was used for estimation of lightning performance of 220 kV overhead power line. Results obtained suggest that swing of suspension insulator strings caused by strong winds may lead to increased risk of lightning shielding failure during thunderstorm. Calculation performed for 3 kA lightning current magnitude shows that at swing angle equal to –1 degree, the horizontal unprotected distance of phase conductor increases by 3.1%, that corresponds to 5.240 m uncovered width. When the swing angle is increased to –5 degree, the uncovered width is increased by 15.8% that corresponds to 5.885 m uncovered width. It is proposed that an increase in the risk of lightning shielding failure as a result of wind load can be accounted by applying an appropriate correction factor in expressions for calculation of shielding failure rate, shielding failure flashover rate, etc. Proposed correction factor should account frequency and strength of wind in the area of transmission line route and depend on transmission line voltage level and tower design. Further efforts should be focused on obtaining and justifying the numerical values of this correction factor.
30 April 2021 in Technology audit and production reserves
The object of the research is a circuit that simulates a lightning strike to a tower of 220 kV power transmission line, taking into consideration the reflection of a current wave from 10 nearest towers. Computation of the voltage arising at the top of the stricken tower is necessary further to determine the lightning performance of transmission line by various methods. For Indian conditions, the average number of lightning strikes to this power line per 100 kilometers per year is about 77, which is a fairly high figure. As a rule, for the tasks of lightning protection, the lightning current is approximated by some analytical expression. In most cases, such expressions are various combinations of exponential functions. However, the waveform of real lightning currents on oscillograms differs significantly from the waveform attributed to them and approximated by relatively simple exponential expressions. For a more detailed study of transient processes caused by thunderstorm activity, there is a need to use oscillograms of real lightning currents when modeling. The problem of determining the voltage at the top of the stricken transmission line tower was solved using circuit simulation. To simulate the lightning current, digitized oscillograms of real lightning currents with peak values of –5.256 kA and –133.586 kA were applied. The article shows that the proposed approach gives a more accurate and visual representation of the transient process at the top of the stricken tower than the approximation of the lightning current by simple exponential expressions. Applying a simplified exponential description of the lightning current leads not only to a simplification of the nature of the transient process at the tower top, but also to an underestimation of the results to 8.8%. The selection of the equivalent circuit for the power line towers also affects the result. Representation of towers in the equivalent circuit with lumped inductances leads to slightly higher values compared to application of surge impedances in the circuit. In this case, the smaller the current amplitude, the greater the difference (8.6 % in the domain of low currents and 1.9 % in the domain of high currents). Since this leads to some reserve during the computations of lightning performance, it is recommended to use an equivalent circuit with lumped inductance for a transmission line tower. The conducted research contributes to the development of methods for calculating the lightning performance of power lines and extends the scope of application of circuit simulation programs.