29 July 2021 in Electrical Engineering & Electromechanics
Purpose. Determination in the analytical form of the maximum limiting influence of the non-identity of the capacitive elements of the high-voltage arm on the amplitude-frequency characteristic and phase-frequency characteristic of the voltage divider with parallel-series connection of R-, C-elements of the high-voltage arm. Methodology. Based on the previously developed theory of broadband voltage dividers with parallel-series connection of R-, C-elements, analytical expressions for amplitude-frequency and phase-frequency characteristics of the voltage divider are obtained and investigated taking into account the limit case of non-identical capacitive elements of high-voltage arm. Results. The nature of the dependencies of the frequency characteristics of the broadband voltage divider on the value of the tolerance of the capacitive elements of the high-voltage arm, the division factor of the voltage divider in a wide range of frequency changes is determined. Simplified approximating expressions for the maximum values of frequency characteristics of the voltage divider are proposed and their error is determined. Originality. For the first time in the analytical form the limiting influence of non-identity of capacitive elements of a high-voltage arm of a voltage divider on its frequency characteristics is considered. A mathematical model of this influence is constructed and the limit values of frequency characteristics of the voltage divider are determined. Practical value. It is recommended to introduce into the normative documentation of broadband voltage dividers the corrected value of the division factor, which allows to significantly reduce the deviation of the actual value of the division factor of the voltage divider from the normalized value in a wide range of frequency changes.
23 April 2023 in Electrical Engineering & Electromechanics
Purpose. Determination in the analytical form of the maximum limiting influence of the non-identity of the resistive elements of the high-voltage arm on the amplitude-frequency characteristic and phase-frequency characteristic of the voltage divider with parallel-series connection of R-, C-elements of the high-voltage arm. Methodology. Based on the previously developed theory of broadband voltage dividers with parallel-series connection of R‑, C-elements, analytical expressions for amplitude-frequency and phase-frequency characteristics of the voltage divider are obtained and investigated taking into account the limit case of non-identical resistive elements of high-voltage arm. Results. The nature of the dependencies of the frequency characteristics of the broadband voltage divider on the value of the tolerance of the resistive elements of the high-voltage arm, the division factor of the voltage divider in a wide range of frequency changes are determined. Simplified approximating expressions for the maximum values of frequency characteristics of the voltage divider are proposed and their error is determined. Originality. For the first time in the analytical form the limiting influence of non-identity of resistive elements of a high-voltage arm of a voltage divider on its frequency characteristics is considered. A mathematical model of this influence is constructed and the limit values of frequency characteristics of the voltage divider are determined. Practical value. It is recommended to introduce into the normative documentation of broadband voltage dividers the corrected value of the division factor, which allows to significantly reduce the deviation of the actual value of the division factor of the voltage divider from the normalized value in a wide range of frequency changes.
2 January 2025 in Electrical Engineering & Electromechanics
Purpose. The aim of this work is the determination of the parasitic capacitance’s influence on the accuracy of scale transformation of high-voltage dividers. Analyzing the possibilities of reducing such influence is a pressing problem for high voltage measurement, especially at high frequency range of input voltage. Methodology. Mathematical modeling of the voltage divider equivalent circuit, considering parasitic capacitances and inductances has been performed in the QUCS circuit simulator software under sinusoidal alternating current conditions in the range from 100 Hz to 1 MHz. Using the FEMM software, the finite element method was used to simulate the density distribution of capacitive currents in the module with capacitance graded insulation of the high-voltage arm of the voltage divider. Results. The results of the calculations show that the percentage of parasitic capacitive currents decreases exponentially depending on the ratio of the outer radii of the shielding disks to the distance between them. However, even with the outer radii of the shielding disks of about 3 m, capacitive currents still make up about 1 % of the total current flowing in the measuring circuit of the voltage divider. Instead of increasing outer radii, it is proposed to use high-voltage capacitance graded insulation between the shielding disks. As a result, a stable error of large-scale voltage transformation was obtained when the values of parasitic capacitances change, and it is proposed to manufacture the high-voltage arm of the voltage divider from the same type of high-voltage modules. Originality. The results of modeling the dependence of the accuracy of the voltage divider scale transformation on the ratio of the structural elements geometric parameters of its high-voltage arm were obtained. The solution has been proposed that involves changing the design of the high-voltage arm of the voltage divider, which significantly reduces the dependence of its scale transformation error on significant changes in the parasitic capacitances of the structure components on grounded surfaces. Practical value. The results of mathematical modeling of the characteristics of the voltage divider high-voltage arm make it possible to design, for the purpose of serial production, the same type of high-voltage modules for assembling on-site broadband voltage dividers for any nominal voltage, which will have the possibility of integration into Smart Grid systems. References 23, tables 1, figures 8.
26 February 2021 in Technology audit and production reserves
The object of research is the equivalent circuit of an impulse current generator designed for testing surge arresters. Calculation of the impulse current generator parameters when discharging a capacitor bank to a complex nonlinear load is a difficult task for an analytical solution. Until now, the application of surge arrester frequency-dependent models was limited to the problems of overvoltage computation. Surge arrester frequency-dependent models can predict the residual voltage with high accuracy. This is the reason to consider that surge arrester frequency-dependent models can be used for calculating the main parameters of impulse current generators designed for physical testing of surge arresters. The task of determining the equivalent circuit parameters required for getting a discharge current of a given waveform and amplitude in an impulse current generator scheme with a nonlinear load was solved using circuit simulation. This article presents the results of studying the processes in impulse current generator equivalent circuit. In the circuit a dynamic model of a surge arrester is used as the load model. For this, an equivalent circuit for the discharge path of the impulse current generator was drawn up. The parameters of the circuit elements (including the required number of capacitors and their charging voltage) are determined, which are necessary for getting a discharge current of a given standardized waveform and amplitude. The parameters of the discharge path are determined for surge arresters of three different voltage classes. It was found that the relative error when determining the residual voltage between the terminals of the surge arrester model does not exceed 3 %. The work contributes to the further development of circuit simulation of surge arresters and the expansion of the scope of surge arrester dynamic models. As a result of the research performed, the possibility of using surge arrester frequency-dependent models for determining the discharge current waveform in impulse current generators is shown. The research performed is relevant due to the fact that surge arresters have become a main tool for protecting the insulation of electrical network equipment against external and internal overvoltages
1 January 2025 in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University