This paper presents a new data-driven methodology for power system coherency identification of generator and non-generator buses. This methodology is exclusively based on intrinsic statistical properties extracted directly from observations, without any prior assumption of the probability distribution function (PDF) for the data. The main advances of this proposal are: ( i ) gathering of statistical information from the data itself despite scenarios where the PDF may change (different inverter-based load and generation scenarios, load levels of the system, and changes in topology); and ( ii ) assignment of buses into coherent areas without any tuning of parameters, nor manually labeling of huge amounts of training data. This new method, called typicality-based data analysis (TDA), is applied to the correlation metric of the distance between dynamic responses of buses, either voltage angles or frequencies. Simulated signals from a benchmark power system with cases considering the presence of non-synchronous generation and islanding conditions, and real data associated with generation trips in the U.S. Eastern Interconnection are used to corroborate the methodology effectiveness.
20 December 2023 in International Journal of Electrical Power & Energy Systems
This paper proposes the FTFT for the real-time monitoring of modern power grids through dynamic harmonic estimations. The FTFT results from the DTTFT implemented with the FFT, instead of its filter bank implementation. In FTFT, the harmonic Taylor-Fourier coefficients are obtained in batch, and from these complex coefficients, estimates of frequency, amplitude, and RoCoF are obtained. The FTFT is embedded in two low-cost platforms, one consisting of a digital signal processor (DSP) coded using C programming language, and a development PMU (D-PMU); where a computationally efficient calculation of the FTFT is coded in both platforms. Both platforms process instantaneous voltage and current signals, rendering phasor and harmonic estimates as if they were extracted by the impulse response of a set of FIR filters and their first and second differentiators of the DTTFT. The phasor and harmonic estimations are accomplished using a sliding window that updates sample by sample, instantaneously providing amplitude, phase, frequency, and RoCoF estimations at the fundamental and harmonic frequencies with a high reporting rate. Experimental results confirm the proposition's performance, precision, and effectiveness under steady-state conditions, sudden changes, and harmonic analysis.
This paper introduces the real-time implementation with the actual hardware architecture environment (HAE) of an online estimation method that tracks the equivalent time-varying inertia in power systems. The proposed method enables automated and accurate inertia estimation, exploiting the ARMAX model representation and the Teager-Kaiser energy operator (TKEO) disturbance time detector. The effectiveness and high accuracy of the proposed framework are successfully validated in laboratory conditions with actual synchronised measurements from Phasor Measurement Units (PMUs) over a real-time emulated New England 39-bus system. The estimate is achieved with a relative error ranging from 0.1% to 7%, even under noisy conditions and atypical measurement values. The literature reviewed does not report any estimation method that is more accurate than the one proposed in this work.
The increasing uptake of inverter based resources (IBRs) has resulted in many new challenges for power system operators around the world. The high level of complexity of IBR generators makes accurate classical model-based stability analysis a difficult task. This letter proposes a novel methodology for solving the problem of estimating the Region of Attraction (ROA) of a nonlinear system by combining classical model based methods with modern data driven methods. Our method yields certifiable inner approximations of the ROA, typical to that of model based methods, but also harnesses trajectory data to yield an improved accurate ROA estimation. The method is carried out by using analytical Lyapunov functions, such as energy functions, in combination with data that is used to fit a converse Lyapunov function. Our methodology is independent of the function fitting method used. In this letter, for implementation purposes, we use Bernstein polynomials to function fit. Several numerical examples of ROA estimation are provided, including the Single Machine Infinite Bus (SMIB) system, a three machine system and the Van-der-Pol system.
25 July 2025 in International Journal of Electrical Power & Energy Systems