Jalil Ali

Jalil Ali

Auto-generated profile, based on publicly available information

Jalil Ali

Asia Metropolitan University

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MBMahdi Bahadoran
Mahdi Bahadoran
ANAhmad Fakhrurrazi Ahmad Noorden
Ahmad Fakhrurrazi Ahmad Noorden
KCKashif Chaudhary
Kashif Chaudhary
FMFaeze Sadat Mohajer
Faeze Sadat Mohajer
MAMuhammad Safwan Aziz
Muhammad Safwan Aziz
PYPreecha Yupapin
Preecha Yupapin
A new photonics biosensor configuration comprising a Double-side Ring Add-drop Filter microring resonator (DR-ADF) made from SiO2-TiO2 material is proposed for the detection of Salmonella bacteria (SB) in blood. The scattering matrix method using inductive calculation is used to determine the output signal’s intensities in the blood with and without presence of Salmonella. The change in refractive index due to the reaction of Salmonella bacteria with its applied antibody on the flagellin layer loaded on the sensing and detecting microresonator causes the increase in through and dropper port’s intensities of the output signal which leads to the detection of SB in blood. A shift in the output signal wavelength is observed with resolution of 0.01 nm. The change in intensity and shift in wavelength is analyzed with respect to the change in the refractive index which contributes toward achieving an ultra-high sensitivity of 95,500 nm/RIU which is almost two orders higher than that of reported from single ring sensors and the limit of detection is in the order of 1 × 10−8 RIU. In applications, such a system can be employed for a high sensitive and fast detection of bacteria.

1 April 2012 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
MBMahdi Bahadoran
Mahdi Bahadoran
AAAbdolkarim Afroozeh
Abdolkarim Afroozeh
JAJalil Ali
Jalil Ali
PYPreecha Yupapin
Preecha Yupapin
We propose a novel design of optical buffer to generate slow light based on delay time. In the framework of the nonlinear waveguide, we investigate propagation of solitons through microring resonators. Dynamical control over slow-light solitons is realized via controlling fields generated by bright soliton and Gaussian pulse. The nonlinear dependence of the velocity of the signal on the controlling field is analytically described. The buffering effect is achieved by slowing the optical signal using an external control light source to vary the dispersion characteristic of the medium via microring resonators. A graphical approach with a signal flow graph method is used to derive the optical transfer functions in z-domain of filters. The characteristics of the optical buffer devices including the transmittance and time delay of the through and drop port are simulated. Simulated results show the criteria of achieving slow light in semiconductor microring resonators. Finally, output signal shows the delay time rate by propagation through the semiconductor microring resonators.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
MRMuhammad Sufi Roslan
Muhammad Sufi Roslan
KCK. T. Chaudary
K. T. Chaudary
ZHZ. Haider
Z. Haider
AZA. F. M. Zin
A. F. M. Zin
JAJ. Ali
J. Ali
Carbon nanomaterials have attracted vast attention due to the rising demand for various nanotechnology applications. The possibility of preparing multi-walled carbon nanotube (MWCNT) and graphene on large scale are demonstrated using direct current arc discharge with transverse magnetic field effect at low ambient pressure. In this work, we study, the effect of external transverse magnetic effect on structural perfection of graphene and multi-walled carbon nanotube. High quality carbon-nanotube were synthesized by arc discharge plasma in Hydrogen ambient at pressure 1 mbar in presence of external transverse magnetic field. The synthesized nanomaterials were characterized by electron microscopy, XRD and Raman Spectroscopy. A significant increase in the quantity and quality of carbon nanotube and graphene in the presence of transverse magnetic field during arc discharge process.

17 November 2011 in Journal of Fusion Energy
Verified
Journal Article
Closed access
PDF file
SSS. H. Saw
S. H. Saw
MAMohamad Akel
Mohamad Akel
PLP. C. K. Lee
P. C. K. Lee
SOS. T. Ong
S. T. Ong
SMS. N. Mohamad
S. N. Mohamad
SLS. Lee
S. Lee

1 July 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
NSNursalwanie Mohd Sabri
Nursalwanie Mohd Sabri
ZHZuhaib Haider
Zuhaib Haider
KTKashif Tufail
Kashif Tufail
FIFairuz Diyana Ismail
Fairuz Diyana Ismail
JAJalil Ali
Jalil Ali
Self-absorption (SA) can drastically affect the emission signal which makes quantitative and, in extreme cases, qualitative investigations very challenging in laser induced plasma spectroscopy. In this study, plasma parameters are spectroscopically studied and SA in aluminum emission lines is investigated at various laser energies and gate delays. Q-switched Nd:YAG laser installed on LIBS2500plus system (1064 nm, 6 ns, 10 Hz) was used for ablation. The sample was ablated in air with different laser energies between 5 and 650 mJ, and spectra were recorded at various gate delays between 0 and 23.75 μs. Intensities of spectral lines Al I 308.2 and 309.3 nm were monitored for the range of laser energies and gate delays. The intensity of spectral lines was increased in response to the increasing laser energy. Rapid increase in intensities was observed for the first microsecond after plasma ignition. The maximum intensity of Al is observed at a gate delay of 1.25 μs. Plasma conditions are investigated on the basis of electron density and temperature in response to the change in laser energy and gate-delay. The electron temperature increased from 15 413 K to 20 200 K and the electron density from 5.0 × 1016 cm−3 to 3.5 × 1018 cm−3 with increase in laser energy from 5 to 650 mJ. The electron temperature is exponentially decreased from 26 733 K to 16 649 K and the electron density is reduced from 2.0 × 1017 cm−3 to 1.0 × 1016 cm−3 for increase in the gate delay from 0 to 23.75 μs. The self-absorption effect in resonant spectral lines of Al is estimated on the basis of SA coefficient calculated using FWHM of spectral lines. The highest values of SA coefficient are found for the lowest laser energies and longest gate delays. It states that the SA is significant when the plasma temperature is low and also, when plasma is least dense. It is fairly obvious to conclude that SA effects are least prevalent when the plasma plume is induced by high laser energies and measurements are made at short gate delays.

1 January 2013 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
KCK. T. Chaudhary
K. T. Chaudhary
ZRZ. H. Rizvi
Z. H. Rizvi
KBK. A. Bhatti
K. A. Bhatti
JAJ. Ali
J. Ali
PYPreecha Yupapin
Preecha Yupapin
Synthesis of multiwalled carbon nanotube (MWCNT) by arc discharge process is investigated with methane (CH4) as background and feedstock gas. The arc discharge is carried out between two graphite electrodes for ambient pressures 100, 300, and 500 torr and arc currents 50, 70, and 90 A. Plasma kinetics such as the density and temperature for arc discharge carbon plasma is determined to find out the contribution of physical parameters as arc current and ambient pressure on the plasma dynamics and growth of MWCNT. With increase in applied arc current and ambient pressure, an increase in plasma temperature and density is observed. The synthesized samples of MWCNT at different experimental conditions are characterized by transmission electron microscopy, scanning electron microscopy, Raman spectroscopy, Fourier transform infrared spectroscopy, and X‐ray diffraction. A decrease in the diameter and improvement in structure quality and growth of MWCNT are observed with increase in CH4 ambient pressure and arc current. For CH4 ambient pressure 500 torr and arc current 90 A, the well‐aligned and straight MWCNT along with graphene stakes are detected.