1 June 2020 in International Journal of Electrical and Computer Engineering (IJECE)
This paper aims to review the previously developed Computer-aided detection (CAD) systems for mammogram screening because increasing death rate in women due to breast cancer is a global medical issue and it can be controlled only by early detection with regular screening. Till now mammography is the widely used breast imaging modality. CAD systems have been adopted by the radiologists to increase the accuracy of the breast cancer diagnosis by avoiding human errors and experience related issues. This study reveals that in spite of the higher accuracy obtained by the earlier proposed CAD systems for breast cancer diagnosis, they are not fully automated. Moreover, the false-positive mammogram screening cases are high in number and over-diagnosis of breast cancer exposes a patient towards harmful overtreatment for which a huge amount of money is being wasted. In addition, it is also reported that the mammogram screening result with and without CAD systems does not have noticeable difference, whereas the undetected cancer cases by CAD system are increasing. Thus, future research is required to improve the performance of CAD system for mammogram screening and make it completely automated.
1 December 2019 in Universal Journal of Electrical and Electronic Engineering
Driver’s drowsiness is one of the leading contributing factors to the increasing accidents statistics in Malaysia. Therefore, the design and development of driver drowsiness detection based on image processing using Raspberry Pi camera module sensor interfacing with Raspberry Pi 3 board are proposed in this paper. To achieve the aim of the research, the Haar Cascade Classifier algorithm is implemented for eyes and face detection whereas for eyes blink (open and close) detection, the Eye Aspect Ratio (EAR) algorithm is employed. From several experiments conducted on six recruited subjects, the findings revealed that the accuracy of Haar Cascade classifier to detect the eyes and faces was subjected to correct sitting position (head must facing to the camera) as well as the eyes must not be covered with glasses or shades. Meanwhile, the range of average EAR value detected by the system was between 0.141 (eyes closed) and 0.339 (eyes opened). In conclusion, the image processing-based Haar Cascade and EAR algorithms utilized on Raspberry Pi platform have been successfully executed. For future improvement, the current board can be replaced with Raspberry Pi Touch Screen to minimize the hardware setup and the physiological based analysis using alcohol and heart rate sensors can be added.
21 May 2014 in Journal of Innovative Optical Health Sciences
This work presents the use of extended Modified Lambert Beer (MLB) model for accurate and continuous monitoring of percent blood carboxyhemoglobin (COHb) (SCO) and oxyhemoglobin (OxyHb) saturation ( SO 2 ) via a fitting procedure. This quantification technique is based on the absorption characteristics of hemoglobin derivatives in the wavelength range of 520–600 nm to give the best estimates of the required parameters. A comparison of the performance of the developed model and MLB law is made using attenuation data from Monte Carlo simulations for a two-layered skin model. The results revealed a lower mean absolute error of 0.4% in the values estimated by the developed model as compared to 10% that is given by the MLB law. This study showed that the discussed approach is able to provide consistent and accurate measurement of blood SO 2 and SCO across different skin pigmentations suggesting that it may potentially be used as an alternative means for clinical diagnosis of carbon monoxide ( CO ) poisoning.
1 December 2019 in Universal Journal of Electrical and Electronic Engineering
4 April 2017 in Journal of Innovative Optical Health Sciences
This paper investigates the appropriate range of values for the transcutaneous blood oxygen saturation (StO2) of granulating tissues and the surrounding tissue that can ensure timely wound recovery. This work has used a multispectral imaging system to collect wound images at wavelengths ranging between 520[ ]nm and 600[ ]nm with a resolution of 10[ ]nm. As part of this research, a pilot study was conducted on three injured individuals with superficial wounds of different wound ages at different skin locations. The StO2value predicted for the examined wounds using the Extended Modified Lambert–Beer model revealed a mean StO2of [ ]% compared to [ ]% at the surrounding tissues, and [ ]% for control sites. These preliminary results contribute to the existing knowledge on the possible range and variation of wound bed StO2that are to be used as indicators of the functioning of the vasomotion system and wound health. This study has concluded that a high StO2of approximately 60% and a large fluctuation in this value should precede a good progression in wound healing.