1 January 2011 in Seismological Research Letters
### Tectonic Settings & Seismicity in New Zealand New Zealand's active tectonics are dominated by the oblique convergence of the Pacific plate and the Australian plate, which produces earthquakes, volcanoes, active geological deformation, and steep terrain. The tectonic setting (Figure 1) makes New Zealand one of the most seismically active countries in the world with more than 15,000 earthquakes ( ML ≥ 2) located per year (http://www.geonet.org.nz/earthquake/). Shallow earthquakes (depth <40 km) cluster in a band that extends along the east coast of the North Island above the Hikurangi subduction zone, through the western South Island in proximity to the Alpine fault, to the southernmost tip of the South Island above the Puysegur subduction zone (Figure 2A). Another band of shallow seismicity maps the Taupo volcanic zone (TVZ), and the cluster beneath the western part of the central North Island is associated with the Cape Egmont fault zone and Egmont Volcano (Mount Taranaki). Figure 2B shows the deep seismicity (≥40 km) of New Zealand. The deep earthquakes beneath the North Island and the upper part of the South Island define the dipping Benioff zone within the subducting Pacific plate. In the Fiordland region the deep seismicity is associated with the subduction of the Australian plate beneath the Pacific plate. Detailed overviews of the seismicity of New Zealand can be found in Robinson (1986), Reyners (1989), Anderson and Webb (1994), and Eberhart-Phillips (1995). ### The GeoNet Project The New Zealand GeoNet is a strongly integrated data collection and analysis system consisting of national and regional-scale sensor networks. In 2001, GNS Science, a New Zealand government-owned research institute, received funding from the New Zealand Earthquake Commission (EQC), a New Zealand government mandated natural disasters insurer, to develop GeoNet as a non-profit “public good” initiative to enhance New Zealand's ability to respond to and prepare for natural hazards such as earthquakes, volcanic eruptions, tsunamis, …
1 October 2007 in Journal of Volcanology and Geothermal Research
27 December 2022 in Space Weather
Geomagnetically induced currents (GICs) are induced in electrical power transmission networks during geomagnetic disturbances. Understanding the magnitude and duration of the GIC expected during worst‐case extreme storm scenarios is vital to estimate potential damages and disruptions to power networks. In this study we utilize the magnetic field waveforms measured during three large geomagnetic storms and scale them to expected worst case extreme storm magnitudes. Multiple methods are used to simulate the varying magnitude of the magnetic field across the different latitudes of New Zealand. Modeled GIC is produced for nine extreme storm scenarios, each covering 1–1.5 days in duration. Our industry partners, Transpower New Zealand Ltd provided GIC magnitude and duration levels which represent a risk to their transformers. Using these thresholds various extreme storm scenarios predict between 44 and 115 New Zealand transformers (13%–35%) are at risk of damaging levels of GIC. The transformers at risk are largely independent of the extreme storm time‐variations, but depend more on the latitude variation scenario. We show that these at‐risk transformers are not localized to any specific region of New Zealand but extend across all regions and include most of the major population centers. A peak mean absolute GIC over a 60‐min window of 920–2,210 A and an instantaneous 1‐min time resolution maximum GIC of 1,590–4,920 A occurs for a worst‐case extreme storm scenario. We believe this is one of the first studies to combine a reasonable worst‐case extreme geomagnetic storm with validated GIC modeling and industry‐provided GIC risk thresholds.
18 February 2022 in Space Weather
Geomagnetically induced currents (GICs) produced during geomagnetic disturbances pose a risk to the safe operation of electrical power networks. One route to determine the hazard of large and extreme geomagnetic disturbances to national electrical networks is a validated model to predict GIC across the entire network. In this study, we improve upon an earlier model for New Zealand, expanding the approach to cover transformers nationwide by making use of multiple storms to develop national scaling factors. We exploit GIC observations which have been made and archived by Transpower New Zealand Ltd, the national grid operator. For some transformers the GIC observations span nearly 2 decades, while for others only a few years. GICs can vary wildly between transformers, particularly due to differences in the electrical network characteristics, transformer properties, and ground conductivity. Modeling these individual transformers is required if an accurate representation of the GIC distribution throughout the network is to be produced. Here we model the GIC during 25 disturbed periods, ranging from large geomagnetic storms to weakly active periods. We adopt the approach of scaling model output using observed GIC power spectra, finding that it improves the correlations between the maximum model and observed GIC by between 10% and 40% depending on the transformer. The modeled GIC at the 73 transformers which have measured GIC are analyzed to create local and national scaling curves. These are used to allow modeling for transformers without in‐situ GIC. We present approaches to utilize this technique for future storms, including non‐monitored transformers.
13 March 2020 in Space Weather
Large geomagnetic storms are a known space weather hazard to power transmission networks due to the effects of geomagnetically induced currents (GICs). However, research in this area has been hampered by a lack of GIC observations. Previous studies have noted that New Zealand is unusually fortunate in having a comparatively dense, high quality, set of GIC measurements, spanning >60 transformers in >20 substations. However, due to operational reasons these observations are clustered in the mid and lower South Island. In this paper we analyze space weather‐induced GIC impact patterns over the entire country by using a different set of sensors that monitor levels of harmonic distortion, with even and odd harmonics measured separately. GICs lead to half cycle transformer saturation and is one of the few ways in which even harmonics are produced in a well‐run power transmission network. We make use of harmonic distortion measurements at 377 circuit breakers made at 126 separate locations. Focusing on the intense geomagnetic storm activity during 6–9 September 2017, we show how the even harmonic distortion observations provide a useful new picture of GIC‐stressed transformers. These observations demonstrate how GIC effects can be monitored by using even harmonic distortion in locations where no GIC measurements are present (e.g., the most of the North Island). We understand that harmonic distortion measurements are fairly common in electrical networks and could provide a new tool for space weather researchers.
5 October 2006 in Bulletin of Volcanology