2 March 2022 in Frontiers in Physics
In the context of improving the detector performance of time-of-flight positron emission tomography (TOF-PET), the combination of charge induction readout and prompt Cherenkov photon production in semiconductor materials can lead to an outstanding detector performance in energy, timing, and spatial resolution. Energy resolutions as good as 1.2% at 662 keV and 5% at 122 keV are reported for pixel thallium bromide (TlBr) detectors. The high refractive index of Tl-based materials, between 2.3 and 2.6, leads to a high Cherenkov photon generation yield but can also challenge photon extraction, potentially affecting the time performance. In this work, the timing properties of TlBr and thallium chloride (TlCl) crystals of different geometries are measured using an optimized test setup with high-frequency readout electronics. A coincidence time resolution (CTR) value of 167 ± 6 ps FWHM is achieved using a 3 × 3 × 3 mm3black-painted TlBr crystal. In order to assess potential improvements, a Geant4-based simulation tool kit is developed and validated against experimental measurements. The simulation tool kit is used to predict the contributions limiting the time resolution regarding the crystal and photodetector properties, highlighting the potential of such materials. Finally, paths to further improve the detector performance in TOF-PET are discussed.
20 May 2024 in Physics in Medicine & Biology
Objective. The efficient usage of prompt photons like Cherenkov emission is of great interest for the design of the next generation, cost-effective, and ultra-high-sensitivity time-of-flight positron emission tomography (TOF-PET) scanners. With custom, high power consuming, readout electronics and fast digitization the prospect of sub-300 ps FWHM with PET-sized BGO crystals have been shown. However, these results are not scalable to a full system consisting of thousands of detector elements. Approach. To pave the way toward a full TOF-PET scanner, we examine the performance of the FastIC ASIC with Cherenkov-emitting scintillators (BGO), together with one of the most recent SiPM detector developments based on metal trenching from FBK. The FastIC is a highly configurable ASIC with 8 input channels, a power consumption of 12 mW ch −1 and excellent linearity on the energy measurement. To put the timing performance of the FastIC into perspective, comparison measurements with high-power consuming readout electronics are performed. Main results. We achieve a best CTR FWHM of 330 ps for 2 × 2 × 3 mm 3 and 490 ps for 2 × 2 × 20 mm 3 BGO crystals with the FastIC. In addition, using 20 mm long LSO:Ce:Ca crystals, CTR values of 129 ps FWHM have been measured with the FastIC, only slightly worse to the state-of-the-art of 95 ps obtained with discrete HF electronics. Significance. For the first time, the timing capability of BGO with a scalable ASIC has been evaluated. The findings underscore the potential of the FastIC ASIC in the development of cost-effective TOF-PET scanners with excellent timing characteristics.
31 October 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
The material requirements for gamma-ray detectors for medical imaging applications are multi-fold and sensitivity is often overlooked. High effective atomic number (Zeff) Cherenkov radiators have raised the attention in the community due to their potential for harvesting prompt photons. A material with one of the highest Zeff and thus short gamma-ray attenuation length is thallium chloride (TlCl). By doping TlCl with beryllium (Be) or iodine (I), it becomes a scintillator and therefore produces scintillation photons upon gamma-ray interaction on top of the prompt Cherenkov luminescence. The scintillation response of TlCl:Be,I is investigated in terms of intensity, energy resolution, kinetics, and timing capability with and without energy discrimination. The ratio of prompt to slow scintillation photons is used to derive the intrinsic number of produced Cherenkov photons and compared with analytic calculations avoiding complex Monte-Carlo simulations. The experimentally determined number of Cherenkov photons upon 511 keV gamma excitation of 17.9 ± 4.6 photons is in line with our simple calculations yielding 14.5 photons. We observe three scintillation decay time components with an effective decay time of 60 ns. The scintillation light yield of 0.9 ph/keV is sufficient to discriminate events with low energy deposition in the crystal which is used to improve the measured coincidence time resolution from 360 ps FWHM without energy selection down to 235 ps after energy discrimination and time walk correction for 2.8 mm thick TlCl:Be,I crystals, and from 580 ps to 402 ps for 15.2 mm thick ones. Already with the first generation of doped TlCl encouraging timing capability close to other materials with lower effective atomic number has been achieved.
17 January 2025 in Physics in Medicine & Biology
Objective. Time resolution is crucial in positron emission tomography (PET) to enhance the signal-to-noise ratio and image quality. Moreover, high sensitivity requires long scintillators, which can cause distortions in the reconstructed images due to parallax effects. This study evaluates the performance of a time-of-flight (TOF)-PET module that makes use of a single-side readout of a mm3 LYSO:Ce matrix with an array of silicon photomultipliers (SiPMs) and a light guide to extract high-resolution TOF and depth of interaction (DOI) information. Approach. This study assesses the performance of the detector prototype using the commercially available TOFPET2 ASIC and SiPMs from various producers. DOI and TOF performance are compared to results using custom-made NINO 32-chip based electronics. Main results. Using a Broadcom NUV-MT array, the detector module read out by the TOFPET2 ASIC demonstrates a DOI resolution of 2.6 ± 0.2 mm full width at half maximum (FWHM) and a coincidence time resolution (CTR) of 216 ± 6 ps FWHM. When read out using the NINO 32-chip based electronics, the same module achieves a DOI resolution of 2.5 ± 0.2 mm and a CTR of 170 ± 5 ps. Significance. The prototype module, read out by commercial electronics and using state-of-the-art SiPMs, achieves a DOI performance comparable to that obtained with custom-made electronics and a CTR of around 200 ps. This approach is scalable to thousands of channels, with only a deterioration in timing resolution compared to the custom-made electronics, which achieve a CTR of 140 ps using a standard non-DOI module.
1 April 2025 in Journal of Instrumentation
This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section 2 × 2 mm2 or 3 × 3 mm2 and length of 3 or 10 mm were coupled to Hamamatsu SiPM and read out by fast high-frequency electronics. Materials whose timing performance relies on Cherenkov emission, namely BGSO, PWO, and PbF2, achieved time resolutions in the range 24–36 ps. Scintillators as L(Y)SO:Ce, GAGG, and BaF2 reached below 15 ps, the best topping at 12.1 ± 0.4 ps. These fast materials are compared to LYSO and their additional benefit is discussed. Given the promising results of BaF2, the study is completed with measurements of the scintillation properties of a set doped with yttrium to quench the slow light emission.