Markus Piller

Mr. Markus Piller


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2022 in IEEE Sensors Journal
Verified
Journal Article
Open access
MPMarkus Piller
Markus Piller
JHJohannes Hiesberger
Johannes Hiesberger
EWElisabeth Wistrela
Elisabeth Wistrela
PMPaolo Martini
Paolo Martini
NLNiklas Luhmann
Niklas Luhmann
SSSilvan Schmid
Silvan Schmid
Nanoelectromechanical (NEMS) resonators are promising uncooled thermal infrared (IR) detectors to overcome existing sensitivity limits. Here, we investigated nanoelectromechanical trampoline resonators made of silicon nitride (SiN) as thermal IR detectors. Trampolines have an enhanced responsivity of more than two orders of magnitude compared to state-of-the-art SiN drums. The characterized NEMS trampoline IR detectors yield a sensitivity in terms of noise equivalent power (NEP) of 7pW/√Hz and a thermal response time as low as 4 ms. The detector area features an impedance-matched metal thin-film absorber with a spectrally flat absorption of 50% over the entire mid-IR spectral range from 1 μm to 25 μm.

20 July 2020 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
MPMarkus Piller
Markus Piller
PSPedram Sadeghi
Pedram Sadeghi
RWRobert G. West
Robert G. West
NLNiklas Luhmann
Niklas Luhmann
PMPaolo Martini
Paolo Martini
SSSilvan Schmid
Silvan Schmid
Nanomechanical silicon nitride (SiN) drum resonators are currently employed in various fields of applications that arise from their unprecedented frequency response to physical quantities. In the present study, we investigate the thermal transport in nanomechanical SiN drum resonators by analytical modeling, computational simulations, and experiments for a better understanding of the underlying heat transfer mechanism causing the thermal frequency response. Our analysis shows that radiative heat loss is a non-negligible heat transfer mechanism in nanomechanical SiN resonators, limiting their thermal responsivity and response time. This finding is important for optimal resonator designs for thermal sensing applications as well as cavity optomechanics.

1 October 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
RBRafael Ballabriga
Rafael Ballabriga
JAJ.A. Alozy
J.A. Alozy
FBF.N. Bandi
F.N. Bandi
GBG. Blaj
G. Blaj
MCM. Campbell
M. Campbell
MBM. van Beuzekom
M. van Beuzekom

14 June 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
AMAntonio Mariscal-Castilla
Antonio Mariscal-Castilla
SFSergio Gomez Fernández
Sergio Gomez Fernández
RMR. Manera
R. Manera
JFJ. M. Fernández-Tenllado
J. M. Fernández-Tenllado
JMJoan Mauricio
Joan Mauricio
David GasconDavid Gascon
David Gascon
Time-of-flight positron emission tomography (TOF-PET) scanners demand electronics that are power-efficient, low-noise, cost-effective, and possess a large bandwidth. Recent developments have demonstrated sub-100 ps time resolution with elevated power consumption per channel, rendering this unfeasible to build a scanner. In this work, we evaluate the performance for TOF-PET of the FastIC front-end using different scintillators and silicon photomultipliers (SiPMs). FastIC is an 8-channel ASIC developed in CMOS 65 nm capable of measuring the energy and the arrival time of a detected pulse with 12 mW per channel. Using Hamamatsu SiPMs (S13360-3050PE) coupled to LSO:Ce:0.2%Ca crystals of 2 × 2 × 3 mm and LYSO:Ce:0.2%Ca of 3.13 × 3.13 × 20 mm, we measured a CTR of (95 ± 3) ps and 156 ± 4) ps FWHM, respectively. With FBK NUV-HD LF2 M0 SiPMs coupled to the same crystals, we obtained a CTR of (76 ± 2) ps and (127 ± 3) ps FWHM. We employed FastIC with a TlCl pure Cherenkov emitter, demonstrating time resolutions comparable to those achieved with high-power-consuming electronics. These findings shows that FastIC represents a cost-effective alternative that can significantly enhance the time resolution of current TOF-PET systems while maintaining low power consumption.

24 August 2020 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
PSPedram Sadeghi
Pedram Sadeghi
MTManuel Tanzer
Manuel Tanzer
NLNiklas Luhmann
Niklas Luhmann
MPMarkus Piller
Markus Piller
MCMiao-Hsuan Chien
Miao-Hsuan Chien
SSSilvan Schmid
Silvan Schmid
Development of broadband thermal sensors for the detection of, among others, radiation, single nanoparticles, or single molecules is of great interest. In recent years, photothermal spectroscopy based on the shift of the resonance frequency of stressed nanomechanical resonators has been successfully demonstrated. Here, we show the application of soft-clamped phononic crystal membranes made of silicon nitride as thermal sensors. It is experimentally demonstrated how a quasi-band-gap remains even at very low tensile stress, in agreement with finite-element-method simulations. An increase of the relative responsivity of the fundamental defect mode is found when compared to that of uniform square membranes of equal size, with enhancement factors as large as an order of magnitude. We then show phononic crystals engineered inside nanomechanical trampolines, which results in additional reduction of the tensile stress and increased thermal isolation, resulting in further enhancement of the responsivity. Finally, defect-mode and band-gap tuning is shown by laser heating of the defect to the point where the fundamental defect mode completely leaves the band gap.

20 May 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MPMarkus Piller
Markus Piller
ACAntonio M Castilla
Antonio M Castilla
GTGiulia Terragni
Giulia Terragni
JAJerome Alozy
Jerome Alozy
EAEtiennette Auffray
Etiennette Auffray
NKNicolaus Kratochwil
Nicolaus Kratochwil
Objective. The efficient usage of prompt photons like Cherenkov emission is of great interest for the design of the next generation, cost-effective, and ultra-high-sensitivity time-of-flight positron emission tomography (TOF-PET) scanners. With custom, high power consuming, readout electronics and fast digitization the prospect of sub-300 ps FWHM with PET-sized BGO crystals have been shown. However, these results are not scalable to a full system consisting of thousands of detector elements. Approach. To pave the way toward a full TOF-PET scanner, we examine the performance of the FastIC ASIC with Cherenkov-emitting scintillators (BGO), together with one of the most recent SiPM detector developments based on metal trenching from FBK. The FastIC is a highly configurable ASIC with 8 input channels, a power consumption of 12 mW ch −1 and excellent linearity on the energy measurement. To put the timing performance of the FastIC into perspective, comparison measurements with high-power consuming readout electronics are performed. Main results. We achieve a best CTR FWHM of 330 ps for 2 × 2 × 3 mm 3 and 490 ps for 2 × 2 × 20 mm 3 BGO crystals with the FastIC. In addition, using 20 mm long LSO:Ce:Ca crystals, CTR values of 129 ps FWHM have been measured with the FastIC, only slightly worse to the state-of-the-art of 95 ps obtained with discrete HF electronics. Significance. For the first time, the timing capability of BGO with a scalable ASIC has been evaluated. The findings underscore the potential of the FastIC ASIC in the development of cost-effective TOF-PET scanners with excellent timing characteristics.