25 May 2021 in Nature Communications
Ultra-compact wireless implantable medical devices are in great demand for healthcare applications, in particular for neural recording and stimulation. Current implantable technologies based on miniaturized micro-coils suffer from low wireless power transfer efficiency (PTE) and are not always compliant with the specific absorption rate imposed by the Federal Communications Commission. Moreover, current implantable devices are reliant on differential recording of voltage or current across space and require direct contact between electrode and tissue. Here, we show an ultra-compact dual-band smart nanoelectromechanical systems magnetoelectric (ME) antenna with a size of 250 × 174 µm2 that can efficiently perform wireless energy harvesting and sense ultra-small magnetic fields. The proposed ME antenna has a wireless PTE 1–2 orders of magnitude higher than any other reported miniaturized micro-coil, allowing the wireless IMDs to be compliant with the SAR limit. Furthermore, the antenna’s magnetic field detectivity of 300–500 pT allows the IMDs to record neural magnetic fields.
4 December 2020 in Science Advances
Nonreciprocity, the defining characteristic of isolators, circulators, and a wealth of other applications in radio/microwave communications technologies, is generally difficult to achieve as most physical systems incorporate symmetries that prevent the effect. In particular, acoustic waves are an important medium for information transport, but they are inherently symmetric in time. In this work, we report giant nonreciprocity in the transmission of surface acoustic waves (SAWs) on lithium niobate substrate coated with ferromagnet/insulator/ferromagnet (FeGaB/Al2O3/FeGaB) multilayer structure. We exploit this structure with a unique asymmetric band diagram and expand on magnetoelastic coupling theory to show how the magnetic bands couple with acoustic waves only in a single direction. We measure 48.4-dB (power ratio of 1:69,200) isolation that outperforms current state-of-the-art microwave isolator devices in a previously unidentified acoustic wave system that facilitates unprecedented size, weight, and power reduction. In addition, these results offer a promising platform to study nonreciprocal SAW devices.
4 June 2021 in IEEE Transactions on Magnetics
The possibility of tuning the magnetic properties of materials with voltage (converse magnetoelectricity) or generating electric voltage with magnetic fields (direct magnetoelectricity) has opened new avenues in a large variety of technological fields, ranging from information technologies to healthcare devices and including a great number of multifunctional integrated systems, such as mechanical antennas, magnetometers, and radio frequency (RF) tunable inductors, which have been realized due to the strong strain-mediated magnetoelectric (ME) coupling found in ME composites. The development of single-phase multiferroic materials (which exhibit simultaneous ferroelectric and ferromagnetic or antiferromagnetic orders), multiferroic heterostructures, as well as progress in other ME mechanisms, such as electrostatic surface charging or magneto-ionics (voltage-driven ion migration), have a large potential to boost energy efficiency in spintronics and magnetic actuators. This article focuses on existing ME materials and devices and reviews the state of the art in their performance. The most recent progress on different ME devices based on ME heterostructures is presented but with a larger emphasis on ME antennas and sensors due to the significant advances achieved in these applications. The rapid development of mechanically actuated ME antennas has been observed over the past several years, producing ME antennas that are miniaturized by 1-2 orders compared to conventional antenna size. Magnetic sensors based on simple ME composites are potentially promising alternatives to conventional magnetometers due to their very good detectivity (<; pT/Hz 1/2 ) at low frequencies. Other ME devices reviewed in this article include RF tunable inductors with high inductance tunability and quality (Q) factor; non-reciprocal microelectromechanical system (MEMS) bandpass filters with dual H- and E-field tunability; passive isolators and gyrators in the low-frequency (LF) range; and ME random access memories for low-power data storage. All these compact and lightweight ME devices are also promising for future biomedical and wireless applications. Finally, some open questions and future directions where the community might be headed are provided.
3 April 2017 in Applied Physics Letters
We report a highly sensitive NEMS DC/low frequency magnetic field sensor consisting of an AlN/FeGaB resonator, with a ΔE effect-based sensing principle. Unlike previously reported magnetic field detection schemes, such as observing induced magnetoelectric voltage, or monitoring impedance, we designed a system to directly measure the reflected output voltage from the sensor as a function of magnetic field. The AlN/FeGaB resonator shows a resonance frequency shift of 3.19 MHz (1.44%), which leads to a high DC magnetic field sensitivity of 2.8 Hz/nT and a limit of detection of 800pT in an unshielded, room temperature and pressure, lab environment.
4 May 2022 in Advanced Electronic Materials