10 February 2022 in IEEE Transactions on Plasma Science
As energy storage elements in modular multilevel converter (MMC) sub-module of a unified power flow controller (UPFC), metallized film capacitors endure ac and dc superimposed voltages, which brings new challenges to insulation performance of the dielectric film. In this article, an experimental setup was created to investigate the breakdown characteristics of the dielectric film for sub-module capacitors. Factors which may affect breakdown strength under ac and dc superimposed voltages were studied experimentally. The results reveal that, as the dc voltage component increases in the range of 0-3200 V, the breakdown strength gradually increases by 16.36%; as the ac voltage component increases in the range of 0-1800 V, the breakdown strength slightly decreases by 3.52%; the breakdown strength is more affected by frequency as the ac voltage component increases and decreases with increasing frequency; as temperature increases from 20 °C to 95 °C, the breakdown strength substantially decreases by 31.12%; as the thickness of the film increases from 7 to 10 μm, the breakdown strength slightly increases by 6.32%. For capacitors in 500-kV UPFC, the dc voltage component is approximately 1600 V; the ac voltage component, whose peak-to-peak value is within 800 V, mainly contains power frequency and the second harmonic components. According to the experimental results, since the ac voltage component is small and the order of harmonic is low, the breakdown strength of capacitors in UPFC has little difference compared with that of the dc capacitors. This article can provide a reference for insulation design optimization of capacitors in UPFC.
24 November 2021 in IEEE Transactions on Plasma Science
The metallized film capacitors in modular multilevel converter (MMC) submodules of unified power flow controller (UPFC) endure ac and dc superimposed voltage, which raises a new problem to the research of capacitor temperature rise. This article presents an experimental setup to perform the capacitor temperature rise experiment under ac and dc superimposed voltage. The effects of ac voltage, dc voltage component, and frequency on the temperature rise of metallized film capacitor are studied experimentally. The experimental results show that dc voltage has no effect on the temperature rise of the capacitor, and the temperature rise can be calculated using the ac voltage component and equivalent series resistance (ESR). According to the equivalent circuit model of the capacitor and experimental results, it can be considered that the equivalent resistance of conductor loss and the dielectric loss factor of the polypropylene film remain unchanged in the frequency range of 0-250 Hz. With the increase in frequency, the proportion of conductor loss power in capacitor increases significantly, and it should be considered in capacitor design. The research results can guide the design and selection of metallized film capacitors in MMC submodules of UPFC.
26 August 2022 in IEEE Transactions on Plasma Science
The surface flashover may occur at the clear edge of metallized films, affecting the insulation performance of metallized film capacitors (MFCs). In this article, an experimental setup was established to investigate the dc surface flashover characteristics of the metallized polypropylene film for MFCs. The effects of voltage setting, parallel capacitance, interlayer pressure, experiment temperature, and clear edge width on the flashover characteristics of metallized films were studied experimentally. The results reveal that, different voltage setting methods affect the surface flashover voltage, with a relatively stable disparity of 14.03%; parallel capacitance has little effect on the flashover characteristics in the range of 0–60 $\mu $ F; the surface flashover voltage and field strength are positively correlated with the interlayer pressure in the range of 50–800 kPa, and negatively correlated with the experiment temperature in the range of 30 $^{\circ}$ C–90 $^{\circ}$ C; as the clear edge width of the metallized film increases from 0.5 to 2.5 mm, the flashover field strength substantially decreases by 49.39% and gradually slows down to saturation. In terms of clear edge design, the width should be determined by the surface flashover voltage under the second voltage setting method; the effect of parallel capacitance on surface flashover can be ignored; measures should be taken to increase the interlayer pressure of outer films, such as increasing the turns of wrapped film outside; the clear edge width should be increased for MFCs operating at high temperature and can be selected according to the experimental data in this article.
30 August 2023 in IEEE Transactions on Plasma Science
Segmented electrode technology is widely used in metalized film capacitors (MFCs) to limit self-healing energy and prevent self-healing failure. However, there is still a lack of research works on the design of the current gate width for ac segmented MFCs. In this article, an experimental platform is built to investigate the current flowing through the breakdown spot under ac voltage, and the effect of different factors on the current action integral is studied. The results reveal that the parallel capacitance has a little effect on the current action integral in the range of 10–160 $\mu $ F; the current action integral is negatively correlated with the interlayer pressure in the range of 20–800 kPa and the temperature in the range of $-$ 20 $^{\circ}$ C to 90 $^{\circ}$ C, while positively correlated with the voltage in the range of 950–1150 V and film thickness in the range of 7–10 $\mu $ m. The fusing criterion of the current gate is also studied experimentally. It is found that for a 1.5 mm wide current gate with square resistance $\beta $ $=$ 2 $\Omega $ / $\QED $ , the current action integral should not exceed 3.295 $\times$ 10 $^{{-5}}$ A $^{{2}}$ s. The design method of the current gate width of segmented MFCs is proposed, and the rationality of the design method is verified by experiments. The research results will provide guidance for the design of the current gate width for segmented MFCs.
13 August 2024 in IEEE Transactions on Plasma Science
The internal fuse plays an important role in the protection of high-voltage (HV) shunt capacitors. However, there is still a lack of research on the design of the internal fuse for HV shunt capacitors. In this article, an experimental platform is built to investigate the effect of the diameter on the fusing characteristics of the fuse. The maximum nonfusing current action integral and the minimum fusing current action integral of fuses with different diameters in the range of 0.3–0.7 mm are obtained. Then, the equivalent circuits of the capacitor unit are analyzed when there is a short between terminals or element breakdown. The current flowing through the fuses with different diameters and lengths is studied, and the current action integral is calculated. Comparing them with the maximum nonfusing current action integral and the minimum fusing current action integral obtained from the experiments, the selection range of fuse diameter and length can be determined. In order to verify the rationality of the fuse design method, the internal fuse of a 668 kvar HV shunt capacitor used in ultrahigh-voltage (UHV) transmission projects is designed and validated experimentally. This article will provide a reference for the internal fuse dimension design of HV shunt capacitors.