Svitlana Fedchenko

Svitlana Fedchenko

Auto-generated profile, based on publicly available information

Svitlana Fedchenko

National University of Civil Protection of Ukraine

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
VNValeriia Nekora
Valeriia Nekora
SPSerhii Pozdieiev
Serhii Pozdieiev
ONOlga Nekora
Olga Nekora
SFSvitlana Fedchenko
Svitlana Fedchenko
VNVadym Nizhnyk
Vadym Nizhnyk
TSTaras Shnal
Taras Shnal
The object of this study is the processes of heating and destruction of glazing in translucent elements of fencing structures. The paper provides data on the computer simulation of a glass panel behavior when it is heated on one side under the conditions of exposure to the standard fire temperature regime. With the help of computer simulation of a glass panel under conditions of thermal influence, the process of heat transfer was reproduced based on the non-stationary heat conduction equation. The stress-strain state of the glass panel was considered using the finite element method. The thermal effect was combined with the mechanical load due to the excess pressure that can occur in the room where the fire originates and develops. To study the propagation of cracks in glass, the strength criterion according to the Johnson-Holmquist model was applied. As a result of computer simulation based on a mathematical model, data were obtained on the dynamics of the formation and propagation of cracks in a glass panel under conditions of heating according to the standard fire temperature regime. It is shown that the glass panel is destroyed through the formation of a system of branched cracks, which is confirmed by empirical experience. The destruction of the glass panel was associated with the onset of the limit state of loss of integrity, and its fire resistance limit was registered based on this attribute. In the work, a comparative analysis of the obtained data with the findings from experimental studies has been carried out. As a result of the comparative analysis, it is shown that the results are adequate since their relative error is on average no more than 8 %, and the F-criterion of adequacy at the significance level of 0.05 does not exceed the tabular value. Based on the results, the possibility of its application for a reliable analysis of the fire resistance of enclosing elements in building structures has been proven

30 June 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
SPSerhii Pozdieiev
Serhii Pozdieiev
ONOlga Nekora
Olga Nekora
SFSvitlana Fedchenko
Svitlana Fedchenko
NZNataliya Zaika
Nataliya Zaika
TSTaras Shnal
Taras Shnal
MNMykhailo Nesukh
Mykhailo Nesukh
This paper proposes a method that makes it possible to study the patterns of changes in the concrete strength of reinforced concrete crossbars depending on the heating temperature under fire conditions by interpreting the results of their standard fire tests. For the implementation of this method, it is proposed to use similar data obtained using mathematical modeling based on the finite element method and given material properties, including the curve of concrete strength reduction recommended by the guidelines, as data included in the set of measurement results during fire tests depending on temperature. Such data are time dependences of temperature indicators at individual cross-section points and time dependence of the maximum deflection of the crossbar. The article proposes an interpolation method that makes it possible to set the temperature at any point of the section based on the approximation of the isotherms by parabolas with a variable indicator of their power. A method based on the mathematical interpretation of temperature indicators obtained using the proposed interpolation method and the curve of the dependence of the maximum deflection on time using a deformation model for describing the stress-strain state is proposed to identify the dependence of the concrete strength of reinforced concrete crossbars. The work also shows that the results obtained using the proposed method of identifying concrete strength reduction coefficients are adequate as their relative error is on average no more than 7 %. Based on the results, the possibility of its application to study the regularities of the decrease in the strength of reinforced concrete crossbars under fire conditions has been proven

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
SPSerhii Pozdieiev
Serhii Pozdieiev
TSTaras Shnal
Taras Shnal
PKPetro Kholod
Petro Kholod
SFSvitlana Fedchenko
Svitlana Fedchenko
INInna Nedilko
Inna Nedilko
The article considers the calculation method for assessing the fire resistance of reinforced concrete beams under the condition of parametric temperature regime of the fire. Temperature analysis for both parametric and standard fire exposure was performed and the corresponding plastic moments depending on the duration of the fire were determined. On the basis of the conducted research the diagrams of limiting moments for reinforced concrete beams are constructed. These diagrams allow you to check the strength conditions and assess the affiliation of reinforced concrete beams to the appropriate standard class of fire resistance. Using the constructed graphs of dependences of limiting plastic moments on the value of fire duration corresponding to standard classes of fire resistance for reinforced concrete beam, it is concluded that the standard temperature of fire is the most severe and leads to a constant reduction of limiting moment in contrast to others with horizontal branches, due to the descending branch of the calculated temperature of the fire according to the parameters of the room. On average, when using the temperature regimes of fire, determined by the proposed mathematical models, the limiting plastic moments are three times less than the limiting plastic moments determined under the influence of the standard temperature of the fire.

1 January 2022 in Emergency Situations: Prevention and Liquidation
Verified
Journal Article
Open access
PDF file
CUCherkasy Institute of Fire Safety Named after Chornobyl Heroes of National University of CivilDefence of Ukraine
Cherkasy Institute of Fire Safety Named after Chornobyl Heroes of National University of CivilDefence of Ukraine
SSStanislav O. Sidnei
Stanislav O. Sidnei
ВКВасиль Кобко
Василь Кобко
SFSvitlana Fedchenko
Svitlana Fedchenko
MZMykola Zmaga
Mykola Zmaga
НЗНаталія Заїка
Наталія Заїка
The work analyzes the existing methods used to determine the fire resistance of hollow-corereinforced concrete slabs. There were carried out numerical experiments using thermalmathematical models of hollow-core reinforced concrete slabs under conditions of fire withduration of 30 minutes, 45 minutes, 60 minutes, and 90 minutes. The functioning of these models isbased on the non-stationary differential equation of thermal conductivity with numericalapproximation using the finite element method. Based on the results of the numerical experiments,the load-bearing capacity of the sectional reinforced concrete slab was determined with duration offire exposure of 30 minutes, 45 minutes, 60 minutes, and 90 minutes, according to the proposedsimplified zone method and the zone method recommended by the standards. Thus, during theresearch there was developed a simplified method for checking the fire resistance of hollow-corereinforced concrete slabs. The proposed method is based on determining the damaged layer ofconcrete in the centers of the half-section zones of hollow-core reinforced concrete slabs, as well astaking into account the thermal influence of a fire on the strength characteristics of steelreinforcement bars.According to the results of a comparative analysis of the existing and proposedmethod, it was established that the error does not exceed 6% with a fire exposure lasting 90minutes, which demonstrates high efficiency in using the proposed method and the possibility of itsapplication for calculating the fire resistance of hollow-core reinforced concrete slabs.Key words: hollow-core reinforced concrete slab, zone method, fire resistance class, firetests.

4 December 2023 in Municipal economy of cities
Verified
Journal Article
Closed access
PDF file
SFS. Fedchenko
S. Fedchenko
The article presents the results of studies of the regularity of changes in the concrete strength of reinforced concrete beams depending on the heating temperature of its inner layers under fire conditions by interpreting the temperature and deformation measurement results. To obtain the data necessary to identify patterns of concrete strength reduction, we developed a method of fire tests that substantiates the experimental base, design, and number of samples, type, number, and location of measuring devices, as well as the method for statistical processing of measurement data. Based on the developed methodology, we conducted fire tests. As a result of the tests, we obtained a set of measurement results in the form of time dependences of temperature indicators at individual cross-section points and the dependence of the maximum beam deflection on time, which are necessary to identify the coefficients of reduction in concrete strength of reinforced concrete beams under fire test conditions. We then used the proposed method to identify regularities in the reduction of concrete strength of a reinforced concrete beam, which includes interpolation using the obtained temperature indicators at individual points of the cross-section of the beam, which allows us to set the temperature at any point of the cross-section at any control time of measurements based on the approximation of isotherms by parabolas with a variable indicator of their degree. At the next stage, to identify the dependence of the concrete strength of reinforced concrete beams, we used a method based on the compilation of systems of equilibrium equations of internal layers in the cross-section of a reinforced concrete beam, in which the unknown values ​​are the coefficients of reduction of concrete strength for a range of temperatures every 100 °С in the range from 20 °С up to 1200 °С, provided that the reduction factor for the specified heating temperature of the inner layer of concrete is determined by linear interpolation. Using the proposed approach, we obtained appropriate results for a reinforced concrete beam subjected to fire tests. The obtained dependences of the strength reduction coefficient were used to evaluate the fire resistance of reinforced concrete beams and crossbars by the calculation method based on the deformation model. By comparing the obtained data with the data from the literature, we established the adequacy of the calculated data based on the relative deviation and Fisher’s test. The totality of the obtained data allows for improving the calculation method for evaluating reinforced concrete crossbars and beams by increasing the accuracy of the data obtained.

1 January 2024 in Emergency Situations: Prevention and Liquidation
Verified
Journal Article
Open access
PDF file
SFSvitlana Fedchenko
Svitlana Fedchenko
SPSerhii Pozdieiev
Serhii Pozdieiev
IFIhor Fedchenko
Ihor Fedchenko
ASAndrii Subota
Andrii Subota
SUState higher educational institution "Uzhhorod National University"
State higher educational institution "Uzhhorod National University"
ІФІгор Федченко
Ігор Федченко
The article presents the results of determining the limit of fire resistance of reinforced concrete crossbars, taking into account the study of identification of strength characteristics of concrete based on the results of fire tests.During the fire tests, two serial reinforced concrete crossbars with the same structural parameters were investigated. The experimental setup made it possible to study full-size elements. The preparation, method of conducting and obtained results of fire tests are described in detail in the previous article. During the fire tests, temperature indicators were obtained at the control points of the cross-section of the tested elements and the value of their maximum deflection depending on the test time.The purpose of this article is based on determining the time of onset of the limit state as a sign of the loss of load-bearing capacity of reinforced concrete crossbars according to the specified concrete strength indicators, calculated based on the results of fire tests.Based on the obtained experimental temperature indicators, temperature interpolation was carried out and temperature distributions in the cross-sections of reinforced concrete crossbars were constructed. The obtained results are adequate, since the F criterion does not exceed the table values and is equal to 0.734. To clarify the strength properties of concrete, a deformation model was used, which is based on the use of equilibrium systems of internal layers in the section. The mathematical apparatus presented in the work allows rewriting the deformation model into a system of linear algebraic equations, the unknowns of which are the concrete strength reduction coefficients.Based on the value of the maximum deflection of the crossbars, the problem of strength was solved and the limit of fire resistance was determined according to the specified coefficients of concrete strength reduction. It is shown that the onset of the limit state due to the loss of bearing capacity is not reached in all cases and is determined according to the technical conditions (approximately 0.3 of the destructive load)М=50кНм.