25 July 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
In this paper, a new low-power and low-voltage configurable-gain small-signal amplifier is proposed. It is based on an active negative resistance circuit and incorporates an improved technique for controlling output common-mode voltage stability in all gain range using a replica bias strategy. The circuit modeling and sizing procedure are described, as well as a prototype version in 180-nm CMOS process for operation with a supply voltage of 0.4 V. The measurement results demonstrate the ability to provide variable gain from 3 to 22 dB for a unity gain frequency of 55 kHz with power consumption in the range of 94 to 549 nW. The performance is comparable to that of state-of-the-art low-voltage variable-gain amplifiers, with the advantage of requiring less silicon area.
1 January 2017 in Genetics and Molecular Research
The use of Y chromosome haplotypes, important for the detection of sexual crimes in forensics, has gained prominence with the use of databases that incorporate these genetic profiles in their system. Here, we optimized and validated an amplification protocol for Y chromosome profile retrieval in reference samples using lesser materials than those in commercial kits. FTA® cards (Flinders Technology Associates) were used to support the oral cells of male individuals, which were amplified directly using the SwabSolution reagent (Promega). First, we optimized and validated the process to define the volume and cycling conditions. Three reference samples and nineteen 1.2 mm-diameter perforated discs were used per sample. Amplification of one or two discs (samples) with the PowerPlex® Y23 kit (Promega) was performed using 25, 26, and 27 thermal cycles. Twenty percent, 32%, and 100% reagent volumes, one disc, and 26 cycles were used for the control per sample. Thereafter, all samples (N = 270) were amplified using 27 cycles, one disc, and 32% reagents (optimized conditions). Data was analyzed using a study of equilibrium values between fluorophore colors. In the samples analyzed with 20% volume, an imbalance was observed in peak heights, both inside and in-between each dye. In samples amplified with 32% reagents, the values obtained for the intra-color and inter-color standard balance calculations for verification of the quality of the analyzed peaks were similar to those of samples amplified with 100% of the recommended volume. The quality of the profiles obtained with 32% reagents was suitable for insertion into databases.