21 April 2021 in High Voltage
The high‐voltage isolated energy supply transformer (HIET) is the key component of the HVDC breaker, which is used for energy transmission and the potential isolation. There is a lack of research results that can meet engineering applications at home and abroad. The design of a 500 kV HIET with dry‐type insulation is proposed, using 10 cascade connected 50 kV sub‐transformers (STs), which uses silicon rubber suitable for DC voltage as the main insulation material. High‐voltage (HV) winding of ST adopts double‐shielding structure of coil semi‐conductive shielding and inner semi‐conductive shielding to improve electric field distribution. The simulation analysis of an electric field at different insulation thicknesses and temperatures shows that the electric field decreases with an increase in thickness of insulation. When the thickness is greater than 25 mm, the electric field reduction effect is significantly weakened. The electric field is closely related to temperature, when at 20°C, the electric field between double‐shielding is relatively uniform. When at 70°C, the inner shielding electric field is much higher than coil shielding, and undergoes obvious reversal. In addition, the 500 kV HIET's electric field has been analysed. The 50 0kV HIET prototype has been manufactured and passed the type test, and successfully applied to the 500 kV Zhangbei DC grid project.
21 November 2019 in IEEE Transactions on Electromagnetic Compatibility
High di/dt during the close-open operation process of hybrid dc breaker will cause differential mode interference (DMI) in the energy supply system of the breaker's driver units due to their inductive coupling. The generated DMI may lead to false action of the breaker, which is an important issue that should be carefully considered in design stage. A method to analyze DMI based on time-domain wideband circuit simulations is proposed in this article. First, a time-domain waveform expression of DMI voltage source is derived, and then wideband equivalent circuit models of major components in the energy supply system are established. Furthermore, a standardized design methodology to reduce DMI is suggested. Applying the method to a high-frequency energy supply system of a ±200 kV hybrid dc breaker, simulation results show that the DMI level for two DMI mitigation measures is reduced by about 90% and 80% of the initial value, respectively.
1 August 2023 in IEEE Transactions on Power Electronics
The modular multilevel converter (MMC) will be subjected to transient impacts, such as switch operation in gas-insulated switchgear and wall bushing flashover, resulting in MMC submodules' ports suffering from fast transient overvoltage (FTO), posing a threat to the safe operation of power devices. This letter proposed an FTO suppression method using gap- RC as an additional snubber circuit and provided a method for selecting RC parameters that can reduce the FTO peak to below the device breakdown voltage. Among them, the gap could avoid additional oscillation processes generated by RC during normal operation of the submodule. Finally, an equivalent experimental circuit for the FTO injection submodule port was designed to verify the effectiveness of gap- RC in suppressing FTO.
9 August 2023 in IEEE Transactions on Power Electronics
In the series-parallel (S-P) compensated inductive power transfer (IPT) system for the electric vehicle charging application, an inductive filter is required after the rectifier on the secondary side to avoid the large charging current surge when the diodes conduct. This article proposes a harmonic modeling method for the S-P compensated IPT systems with an inductive filter where both the fundamental and higher order harmonics are considered. Compared to the well-known fundamental harmonic approximation (FHA) method, a more accurate description can be obtained by constructing the circuit model at different harmonics, especially in a strongly coupled case. The zero-voltage switching (ZVS) condition is derived, which shows that a larger load current will cause the power switches to lose ZVS. A larger coupling coefficient will help increase the ZVS range. The output dc voltage will drop slightly due to the high order harmonics, which is different from the FHA method where the output voltage is constant regardless of the load. Experimental results are provided to validate the effectiveness of the proposed harmonic modeling method of the S-P compensated IPT system.
20 August 2007 in Journal of the Optical Society of America A
Speckle patterns of arbitrary resolution are obtained by applying the sampling theorem to measurements of two orthogonal components of the microwave field transmitted through multiply scattering samples. Core structures of phase singularities, phase critical points, and polarization singularities are explored. We find that equiphase lines connect phase singularities with opposite topological signs except for the bifurcation lines, which run through a phase saddle point, in agreement with predictions by Freund [Phys. Rev. E 25, 2348 (1995) ]. We observe hyperbolic equiphase lines near phase saddle points and elliptical equiphase lines around phase extrema. Polarization singularities of the vector field with the three morphologies predicted are observed.
9 May 2023 in IEEE Transactions on Power Delivery
Compared with high voltage column-type air-core reactors (HVCAR), high voltage toroid-type air-core reactors (HVTAR) generate much smaller external magnetic flux density (EMD) during operation, which significantly reduces magnetic clearance (MC), thereby reducing space occupied by air-core reactors. For HVTAR, existing methods such as finite element method (FEM) and numerical integration methods using the Biot-Savart law, cannot reveal the influence of the parameters of reactors on EMD. This paper proposes an analytic formula for EMD, in view of the special winding structure of HVTAR. It can directly reveal the influence of the working current, the number of coil units, n, and the size of the reactor on EMD. The analysis shows that the EMD decays with ρn+1 P, which is much faster than the attenuation rate of ρ3 Pof column-type reactors. The analytic formula is verified by comparison with the results of FEM. The analytic formula is simple and practical to calculate the EMD and MC quickly and guide the electromagnetic design of HVTAR directly.