A carbon paste electrode bulk was modified with MnO2 and investigated for use as an electrochemical sensor for riboflavin (vitamin B2) using differential pulse voltammetry (DPV). Riboflavin displays a well expressed oxidation peak at −0.15 V (versus Ag/AgCl) in solutions with a pH value of 2. Effects of pH value, pulse amplitude and pulse time were optimized by employing DPV. The signals obtained are linearly related to the concentrations of riboflavin in the range from 0.02 to 9 μM. Other features include a 15 nM detection limit, and good reproducibility (±3 %) and repeatability (±2 %). Interferences by common compounds were tested, and the method was successfully applied to the determination of riboflavin in pharmaceutical formulations where is gave recoveries in the range from 95 to 97 %. Manganese(IV) oxide was used as a modifier for the carbon paste electrode (MnO2/CPE) for improving its performance toward riboflavin oxidation. Cyclic voltammetry and differential voltammetry were used for characterization and determination of riboflavin, respectively.
In this work new designed, highly sensitive electrochemical method is developed for the determination of nitrites in tap water using glassy carbon electrode modified with graphene nanoribbons (GNs/GCE). Graphene nanoribbons (GNs) have been newly synthetized and aligned to the surface of glassy carbon electrode (GCE) and exhibited excellent electrocatalytic activity for nitrite oxidation with a very high peak currents. Studies about electrochemical behavior and optimization of the most important experimental conditions were done using cyclic voltammetry (CV), while quantitative studies were done with amperometric detection. Nitrite provides a well-defined, oxidation peak at +0.9V (vs. Ag/AgCl, 3.0M KCl) in Britton-Robinson buffer solution (BRBS) at pH 3. The influence of most possible interferent ions has been examined and was found to be negligible. Under optimized experimental conditions in BRBS at pH 3 linear calibration curves were obtained in the range from 0.5 to 105µM with the detection limit of 0.22µM. Reproducibility of ten replicate measurements of 1µM of nitrite was estimated to be 1.9%. Proposed method and constructed sensor is successfully applied for the determination of nitrite present in tap water samples without any pretreatment. This developed method represents inexpensive analytical alternative approach compared to other analytical methods.
1 June 2016 in Journal of Electroanalytical Chemistry