William A. Osborn

William A. Osborn

Auto-generated profile, based on publicly available information

William A. Osborn

Materials Measurement Science Division, Material Measurement Laboratory, National Institute of Standards and Technology 1 , Gaithersburg, Maryland 20899

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2015 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
FYFeng Yi
Feng Yi
WOWilliam Osborn
William Osborn
JBJordan Betz
Jordan Betz
DLDavid A. LaVan
David A. LaVan
We evaluate the microstructural and electrical stability of Pt thin films with Ti or Ta as the adhesion layer after furnace annealing and rapid thermal annealing up to 750°C in three different environments. Test devices were made with 100 nm of Pt with a 10-nm adhesion layer. After annealing, the resistance anomalously increased for samples annealed in ultrahigh purity N 2 (UHP, 99.999%), while the resistance decreased, as expected, for samples annealed in 99.95% N 2 or air. The Ta/Pt film stack shows better microstructural and electrical stability compared with Ti/Pt. X-ray photoelectron spectroscopy (XPS) data indicate that diffusion of the Ti and Ta adhesion layers through the Pt film occurs in samples annealed in UHP N 2 , which is responsible for the remarkable increase of resistance. For samples annealed in air, the oxidation of Ti/Ta suppresses the diffusion process and expected grain growth occurs in the Pt, thus decreasing the resistance. Furthermore, XPS elemental mapping and atomic force microscope imaging shed light on void formation/dewetting seen under certain conditions.

1 March 2022 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
DJD. Josell
D. Josell
WOW. A. Osborn
W. A. Osborn
MWM. E. Williams
M. E. Williams
HMH. Miao
H. Miao
This work extends an extreme variant of superconformal Au electrodeposition to deeper device architectures while exploring factors that constrain its function and the robustness of void-free processing. The unconventional bottom-up process is used to fill diffraction gratings with trenches 94 μ m deep and 305 μ m deep, with aspect ratios (height/width) of just below 20 and 15, respectively, in near-neutral 0.16 mol∙l −1 Na 3 Au(SO 3 ) 2 + 0.64 mol∙l −1 Na 2 SO 3 electrolyte containing 50 μ mol∙l −1 Bi 3+ . Although the aspect ratios are modest compared to previously demonstrated void-free filling beyond AR = 60, the deepest trenches filled exceed those in previous work by 100 μ m—a nearly 50% increase in depth. Processes that substantially accelerate the start of bottom-up deposition demonstrate a linkage between transport and void-free filling. Final profiles are highly uniform across 65 mm square gratings because of self-passivation inherent in the process. Electron microscopy and electron backscatter diffraction confirm the fully dense Au and void-free filling suggested by the electrochemical measurements. X-ray transmission “fringe visibility” averages more than 80% at 50 kV X-ray tube voltage across the deeper gratings and 70% at 40 kV across the shallower gratings, also consistent with uniformly dense, void-free fill across the gratings.

1 October 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
IMIzak McGieson
Izak McGieson
SAShane Q. Arlington
Shane Q. Arlington
LNLakshmi Ravi Narayan
Lakshmi Ravi Narayan
WOWilliam Osborn
William Osborn
MGMichael D. Grapes
Michael D. Grapes
FYFeng Yi
Feng Yi
Nanocalorimetry is a thermal analysis technique utilizing microfabricated sensors capable of characterizing phase transformations and chemical reactions both isothermally or at fast heating and cooling rates when operated in a scanning mode. Here, a nanocalorimeter was designed to operate in a transmission electron microscope (TEM) holder compatible with TEMs with a narrow pole piece gap. The nanocalorimeters have an electrical connection design to enable in situ TEM observation during high-rate thermal measurements. Both 10 nm alumina and 20 nm silicon nitride membranes were realized as TEM observation windows, to allow for high resolution and high-speed imaging. For certain specimens, the nanocalorimeters may be fabricated with small perforations so the specimen may be imaged over vacuum without any support layer, as demonstrated for a 25 nm thick gold film. Elimination of the amorphous silicon nitride under the TEM observation region reduces the background signal. Preliminary measurements demonstrate the versatility of the nanocalorimeter for in situ TEM observation. Synchronizing nanocalorimetry with a high-frame-rate direct electron detector further extends the measurement capability to couple thermal analysis with the evolution of microstructure.

18 February 2019 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
WOWilliam A. Osborn
William A. Osborn
MMMark J. McLean
Mark J. McLean
BBBrian Bush
Brian Bush
Applying high-resolution electron backscatter diffraction (HR-EBSD) to materials without regions that are amenable to the acquisition of backgrounds for static flat fielding (background subtraction) can cause analysis problems. To address this difficulty, the efficacy of electron beam induced deposition (EBID) of material as a source for an amorphous background signal is assessed and found to be practical. Using EBID material for EBSD backgrounds allows single crystal and large-grained samples to be analyzed using HR-EBSD for strain and small angle rotation measurement.

16 October 2023
Verified
Report
Closed access
RGRichard S Gates
Richard S Gates
WOWilliam A Osborn
William A Osborn
MMMark J McLean
Mark J McLean
GSGordon A Shaw
Gordon A Shaw
JFJames J Filliben
James J Filliben
A batch of 94 silicon chips containing arrays of uniform rectangular cantilevers was microfabricated from a single silicon wafer and their stiffnesses and resonance frequencies calibrated using a laser Doppler vibrometer (LDV). The cantilevers are 50 μm wide, (about the width of a human hair), and vary in length from 600 μm to 300 μm. They have stiffness values nominally ranging from 0.03 N/m to 0.2 N/m and nominal first flexural resonance frequencies in the range of 5 kHz to 21 kHz respectively. The LDV cantilever stiffness calibration measurements proved very reliable and combined expanded uncertainties better than ± 3% in stiffness were obtained for individual devices. These devices can be used as reference artifacts to validate atomic force microscopy (AFM) cantilever stiffness measurement methods as well as directly calibrating AFM test cantilever stiffness using the reference cantilever method. This NIST SP-260 provides details on the source and preparation of the devices as well as the analytical approach of using a laser Doppler vibrometer to accurately measure both stiffness (k), resonance frequency (f0), and Quality factor (Q) of each cantilever. The statistical analysis applied to the data sets is described. An example of the reference cantilever method is also provided for individuals wishing to use these devices to make direct calibrations of AFM test cantilevers.