Guanzhong Gong

Guanzhong Gong

Auto-generated profile, based on publicly available information

Guanzhong Gong

Department of Radiation Physics, Shandong First Medical University Affiliated Cancer Hospital, Shandong Cancer Hospital and Institute, Jinan, 250117, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2023 in European Radiology
Verified
Journal Article
Closed access
PDF file
RLRuikun Li
Ruikun Li
YGYujie Guo
Yujie Guo
ZZZhongchen Zhao
Zhongchen Zhao
MCMingming Chen
Mingming Chen
XLXiaoqing Liu
Xiaoqing Liu
LWLisheng Wang
Lisheng Wang

20 December 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
GGGuanzhong Gong
Guanzhong Gong
RWRuozheng Wang
Ruozheng Wang
YGYujie Guo
Yujie Guo
DZDeyin Zhai
Deyin Zhai
TLtonghai hai Liu
tonghai hai Liu
YYYong Yin
Yong Yin
Background: Lung radiation injury is a critical complication of radiotherapy (RT) for thoracic esophageal carcinoma (EC). Therefore, the goal of this study was to investigate the feasibility and dosimetric effects of reducing the lung tissue irradiation dose during RT for thoracic EC by applying volumetric modulated arc radiotherapy (VMAT) combined with active breathing control (ABC) for moderate deep inspiration breath-hold (mDIBH). Methods: Fifteen patients with thoracic EC were randomly selected to undergo two series of computed tomography (CT) simulation scans with ABC used to achieve mDIBH (representing 80% of peak DIBH value) versus free breathing (FB). Gross tumor volumes were contoured on different CT images, and planning target volumes (PTVs) were obtained using different margins. For PTV-FB, intensity-modulated radiotherapy (IMRT) was designed with seven fields, and VMAT included two whole arcs. For PTV-DIBH, VMAT with three 135° arcs was applied, and the corresponding plans were named: IMRT-FB, VMAT-FB, and VMAT-DIBH, respectively. Dosimetric differences between the different plans were compared. Results: The heart volumes decreased by 19.85%, while total lung volume increased by 52.54% in mDIBH, compared to FB (p < 0.05). The mean conformality index values and homogeneity index values for VMAT-DIBH (0.86, 1.07) were slightly worse than those for IMRT-FB (0.90, 1.05) and VMAT-FB (0.90, 1.06) (p > 0.05). Furthermore, compared to IMRT-FB and VMAT-FB, VMAT-DIBH reduced the mean total lung dose by 18.64% and 17.84%, respectively (p < 0.05); moreover, the V5, V10, V20, and V30 values for IMRT-FB and VMAT-FB were reduced by 10.84% and 10.65% (p > 0.05), 12.5% and 20% (p < 0.05), 30.77% and 33.33% (p < 0.05), and 50.33% and 49.15% (p < 0.05), respectively. However, the heart dose-volume indices were similar between VMAT-DIBH and VMAT-FB which were lower than IMRT-FB without being statistically significant (p > 0.05). The monitor units and treatment time of VMAT-DIBH were also the lowest (p < 0.05). Conclusions: VMAT combined with ABC to achieve mDIBH is a feasible approach for RT of thoracic EC. Furthermore, this method has the potential to effectively reduce lung dose in a shorter treatment time and with better targeting accuracy.

8 February 2021 in Medical Physics
Verified
Journal Article
Closed access
PDF file
QQQingtao Qiu
Qingtao Qiu
ZYZiduo Yang
Ziduo Yang
SWShuyu Wu
Shuyu Wu
DQDongdong Qian
Dongdong Qian
JWJun Wei
Jun Wei
YYYong Yin
Yong Yin

26 January 2023 in IEEE Transactions on Parallel and Distributed Systems
Verified
Journal Article
Closed access
JXJie Xue
Jie Xue
LRLiwen Ren
Liwen Ren
BSBosheng Song
Bosheng Song
YGYujie Guo
Yujie Guo
JLJie Lu
Jie Lu
DLDengwang Li
Dengwang Li
Neural-like P systems are membrane computing models inspired by natural computing and are viewed as third-generation neural network models. Although real neurons have complex structures, classical neural-like P systems simplify the structures and corresponding mechanisms to two-dimensional graphs or tree-based firing and forgetting communications, which limit the real applications of these models. In this paper, we propose a hypergraph-based numerical neural-like (HNN) P system containing five types of neurons to describe the high-order correlations among neuron structures. Three new kinds of communication mechanisms among neurons are also proposed to address numerical variables and functions. Based on the new neural-like P system, a tumor/organ segmentation model for medical images is developed. The experimental results indicate that the proposed models outperform the state-of-the-art methods based on two hippocampal datasets and a multiple brain metastases dataset, thus verifying the effectiveness of the HNN P system in correctly segmenting tumors/organs.

24 January 2024 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
RLRui Liu
Rui Liu
GGGuanZhong Gong
GuanZhong Gong
KMKangNing Meng
KangNing Meng
SDShanshan Du
Shanshan Du
YYYong Yin
Yong Yin
Whole-brain radiotherapy (WBRT) plays an irreplaceable role in the treatment of brain metastases (BMs), but cognitive decline after WBRT seriously affects patients’ quality of life. The development of cognitive dysfunction is closely related to hippocampal injury, but standardized criteria for predicting hippocampal injury and dose limits for hippocampal protection have not yet been developed. This review systematically reviews the clinical efficacy of hippocampal avoidance - WBRT (HA-WBRT), the controversy over dose limits, common methods and characteristics of hippocampal imaging and segmentation, differences in hippocampal protection by common radiotherapy (RT) techniques, and the application of artificial intelligence (AI) and radiomic techniques for hippocampal protection. In the future, the application of new techniques and methods can improve the consistency of hippocampal dose limit determination and the prediction of the occurrence of cognitive dysfunction in WBRT patients, avoiding the occurrence of cognitive dysfunction in patients and thus benefiting more patients with BMs.

29 March 2021 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
YQYuxiao Qi
Yuxiao Qi
JLJieyu Li
Jieyu Li
HCHuai Chen
Huai Chen
YGYujie Guo
Yujie Guo
YYYong Yin
Yong Yin
LWLisheng Wang
Lisheng Wang