An experimental campaign of 25 long-duration (13–47 days) laboratory tests was carried out with three complex pier models under steady clear-water flow conditions. Each model, characterized by a different relation between the column and the pile-cap widths, Dc/Dpc, was tested for a variety of pile-cap positions relatively to the initial bed, Hc. The experimental data were used to describe the temporal evolution of the scour depth as a function of Hc/h (h = approach flow depth). The common criterion to stop experimental tests on complex piers was analyzed, and a new criterion was introduced. The equilibrium scour depth, dse, was calculated by extrapolation of data series. The results are used to evaluate the effect of Dc/Dpc and Hc/h on dse when the pile cap is above the bed (Situation 1), partially buried in the bed (Situation 2), and completely buried in the bed (Situation 3). The analysis includes the definition of Hc at which the maximum dse occurs through an equation that takes into account th...
This paper presents a new prioritisation approach to the problem of rehabilitation of water distribution systems. It consists in a algorithm that, based on the resilience index and on the unitary power concepts, selects the most important pipes to be replaced in order to achieve two main objectives: first, to reduce loss of water due to leakage by decreasing and levelling pressures along the entire network; second, to reduce the dissipated energy in the system, making it more efficient and reliable. Additionally, the implemented algorithm finds profitable rehabilitation schemes and allows the identification of the appropriate point at which, according to the economic and hydraulic criteria established by the user, the process of replacing pipes should be stopped. This paper includes three case studies – one hypothetical and two real water distribution systems – in which the algorithm was tested. For these networks hydraulically and economically near-optimal rehabilitation schemes were achieved.
1 November 2016 in Journal of Hydraulic Engineering
At present, bridges are frequently built with geometries that consist of a column founded on a pile cap and supported by an array of piles, referred to as common complex piers or most often (as also in this paper), briefly, as complex piers. This paper addresses prediction of local scour depth at those complex piers. An experimental campaign of 48 long-duration tests was performed with seven complex pier models under steady clear-water flow conditions to quantify the influence of the relative column width, Dc/Dpc (Dc = column width, Dpc = pile cap width), the relative pile cap thickness, T/h (T = pile cap thickness, h = approach flow depth), and the pile-group configuration on the equilibrium scour depth, dse. Several tests were carried out for the possible range of variations in the pile cap position relatively to the initial bed level. The values of dse were estimated by extrapolation of the experimental data series. The performance of three methods, i.e., Auckland, HEC-18, and Florida Departmen...
In the present study, a new physically sound approach to experimentally obtain the contribution of each complex pier component to the ensemble scour depth is presented and illustrated. The new approach can be assumed to take into account the interactions of the different flow structures and their impact on the local scour depth. A total of 67 long-duration tests were performed to quantify those contributions according to the new approach, 35 of which were run in the scope of this study. Results showed that the contribution of each component is highly dependent on its position relative to the initial bed level and on the pier geometry. The experimental results obtained through the new approach were compared with the predictions of two widely accepted methods, showing that these tend to implicitly disregard interactions and joint effects of the different complex pier components with or on the flow structure.
WDN operation involves two main issues: pipes rehabilitation and reduction of NRW; both with large economical repercussions. This paper presents an algorithm developed by CIACUA which selects the most important pipes to be replaced in terms of reducing power dissipation inside WDN. Additionally, it finds an optimal alternative for WDN operators to plan system's rehabilitation in terms of the enterprise's economic benefits. This paper includes analysis of two case studies of WDN, one with a regular topography and another with strong topographic variability. In both cases the methodology proved successful.