Guoliang Xiao

Guoliang Xiao

Auto-generated profile, based on publicly available information

Guoliang Xiao

Southwestern Institute of Physics 1 , Chengdu 610041

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GXGuoliang Xiao
Guoliang Xiao
JYJiao Yin
Jiao Yin
CCChengyuan Chen
Chengyuan Chen
BFBeibin Feng
Beibin Feng
WZWulyu Zhong
Wulyu Zhong
XDXuru Duan
Xuru Duan
The supersonic molecular beam injection (SMBI) technique is widely used in magnetic fusion devices for plasma fueling and active control of particles. The beam flow formed by the SMBI system is directly visualized by a newly established schlieren diagnostic system on the SMBI testing platform. This schlieren system could provide a 2D density distribution of the beam with the sub-mm spatial resolution by detecting the change in the refractive index of the medium caused by the SMBI in the low-pressure vacuum chamber. The structure and the divergence angle of the supersonic molecular beam for fusion plasma fueling are first measured. Additionally, the density profile of the supersonic molecular beam is reconstructed from the measured light intensity by the schlieren system. The experimental comparison between the standard nozzle and the optimized nozzle of the SMBI system shows the great potential of the diagnostic system in optimizing the beam characteristics.

1 November 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
JWJ. Wen
J. Wen
ZSZ. B. Shi
Z. B. Shi
WZW. L. Zhong
W. L. Zhong
XZX. L. Zou
X. L. Zou
MJM. Jiang
M. Jiang
XJX. Q. Ji
X. Q. Ji
High confinement mode plasma experiments with Type-I edge localized modes (ELMs) have been carried out on HL-2A tokamak. With neutral beam injection and lower hybrid current drive heating, a quasi-coherent mode (QCM) located at pedestal region has been observed, which exists during the ELM-free stage till the first ELM burst. Analysis based on density and magnetic fluctuations has revealed that the QCM propagating radially outward is electrostatic in nature whose radial wavenumber is kr∼0.5 cm−1 as well as the poloidal wavenumber around kθ∼1.4 cm−1, rotating in electron diamagnetic drift direction. The central frequency of the mode gradually decreases from 50 to 20 kHz, which varies almost linearly with toroidal rotation. Experimental findings indicate that the QCM is excited above a critical electron density gradient in the ELM-free phase during which the latter gradually increases due to the confinement transition. The disappearance of QCM is closely associated with the onset of ELMy H-mode, suggesting that the presence of QCM could potentially delay the occurrence of ELM bursts, consequently supporting the maintenance of an ELM-free operational regime. Moreover, the pedestal region locates more radially outside where the density gradient shows a more spanned region with QCM. A quantitative comparison between experimental measurements and linear GENE gyrokinetic simulations suggests that the dissipative trapped electron mode might be the candidate interpretation of the QCM.

1 December 2020 in Journal of Fusion Energy
Verified
Journal Article
Closed access
PDF file
GXG. L. Xiao
G. L. Xiao
WZW. L. Zhong
W. L. Zhong
YZY. P. Zhang
Y. P. Zhang
XZX. L. Zou
X. L. Zou
ALA. S. Liang
A. S. Liang
XDX. R. Duan
X. R. Duan

1 November 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
CWC. Y. Wang
C. Y. Wang
WXWeiwen Xiao
Weiwen Xiao
GXG. L. Xiao
G. L. Xiao
GTG. R. Tynan
G. R. Tynan
JYJ. Yin
J. Yin
XDX. R. Duan
X. R. Duan
A two-photon absorption laser induced fluorescence (TALIF) diagnostic system is designed for measuring the density of deuterium atoms in the scrape-off layer (SOL) region of the Huanliu-3 (HL-3) tokamak. The system employs laser pulses at 10 Hz with an energy of 10 mJ per pulse (pulse width <8 ns) at 205 nm. To enhance the fluorescence intensity, a semi-confocal lens was designed to achieve a relatively large solid angle for fluorescence collection. A calibration experiment was conducted, establishing the relationship between fluorescence intensity and atomic deuterium (D) density using krypton (Kr) atoms as a reference. Experimental verification of the whole TALIF system has been successfully performed in a plasma environment. The feasibility of the TALIF for the measurements of the neutral particles is discussed, and an experimental result in the HL-3 tokamak edge plasma region is shown in this paper.