Chengyuan Chen

Chengyuan Chen

Auto-generated profile, based on publicly available information

Chengyuan Chen

Southwestern Institute of Physics 1 , P.O. Box 432, Chengdu 610041

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ZSZhongbing Shi
Zhongbing Shi
WZWulu Zhong
Wulu Zhong
MJMin Jiang
Min Jiang
ZYZengchen Yang
Zengchen Yang
BZBoyu Zhang
Boyu Zhang
XDXuru Duan
Xuru Duan
A novel 16-channel fixed frequency Doppler backward scattering (DBS) reflectometer system has been developed on the HL-2A tokamak. This system is based on the filter-based feedback loop microwave source (FFLMS) technique, which has lower phase noise and lower power variation compared with present tunable frequency generation and comb frequency array generation techniques [J. C. Hillesheim et al. Rev. Sci. Instrum. 80, 083507 (2009) and W. A. Peebles et al. Rev. Sci. Instrum. 81, 10D902 (2010)]. The 16-channel DBS system is comprised of four × four-frequency microwave transmitters and direct quadrature demodulation receivers. The working frequencies are 17-24 GHz and 31-38 GHz with the frequency interval of 1 GHz. They are designed to measure the localized intermediate wave-number (k⊥ρ ∼ 1–2, k⊥ ∼ 2–9 cm−1) density fluctuations and the poloidal rotation velocity profile of turbulence. The details of the system design and laboratory tests are presented. Preliminary results of Doppler spectra measured by the multi-channel DBS reflectometer systems are obtained. The plasma rotation and turbulence distribution during supersonic molecular beam injection are analyzed.

17 July 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ZSZhongbing Shi
Zhongbing Shi
WZWulyu Zhong
Wulyu Zhong
ZYZengchen Yang
Zengchen Yang
ALAnshu Liang
Anshu Liang
JWJie Wen
Jie Wen
QYQingwei Yang
Qingwei Yang
The Doppler backward scattering (DBS) reflectometer has become a well-established and versatile diagnostic technique for the measurement of density fluctuations and flows in magnetically confined fusion experiments. In this work, a novel multiple fixed-frequency array source with a multiplexer technique is developed and applied in the multi-channel DBS system. The details of the system design and laboratory tests are presented. Preliminary results of Doppler shift frequency spectra measured by the multi-channel DBS reflectometer systems are obtained. Characteristics of plasma rotation and turbulence before and after supersonic molecular beam injection are analyzed.

1 September 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
CCC. Y. Chen
C. Y. Chen
DYD. L. Yu
D. L. Yu
BFB. B. Feng
B. B. Feng
LYL. H. Yao
L. H. Yao
XSX. M. Song
X. M. Song
XDX. R. Duan
X. R. Duan
On HL-2A tokamak, supersonic molecular beam injection (SMBI) has been developed as a routine refueling method. The key components of the system are an electromagnetic valve and a conic nozzle. The valve and conic nozzle are assembled to compose the simplified Laval nozzle for generating the pulsed beam. The appurtenance of the system includes the cooling system serving the cooled SMBI generation and the in situ calibration component for quantitative injection. Compared with the conventional gas puffing, the SMBI features prompt response and larger fueling flux. These merits devote the SMBI a good fueling method, an excellent plasma density feedback control tool, and an edge localized mode mitigation resource.

1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GXGuoliang Xiao
Guoliang Xiao
JYJiao Yin
Jiao Yin
CCChengyuan Chen
Chengyuan Chen
BFBeibin Feng
Beibin Feng
WZWulyu Zhong
Wulyu Zhong
XDXuru Duan
Xuru Duan
The supersonic molecular beam injection (SMBI) technique is widely used in magnetic fusion devices for plasma fueling and active control of particles. The beam flow formed by the SMBI system is directly visualized by a newly established schlieren diagnostic system on the SMBI testing platform. This schlieren system could provide a 2D density distribution of the beam with the sub-mm spatial resolution by detecting the change in the refractive index of the medium caused by the SMBI in the low-pressure vacuum chamber. The structure and the divergence angle of the supersonic molecular beam for fusion plasma fueling are first measured. Additionally, the density profile of the supersonic molecular beam is reconstructed from the measured light intensity by the schlieren system. The experimental comparison between the standard nozzle and the optimized nozzle of the SMBI system shows the great potential of the diagnostic system in optimizing the beam characteristics.

1 November 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
CWC. Y. Wang
C. Y. Wang
WXWeiwen Xiao
Weiwen Xiao
GXG. L. Xiao
G. L. Xiao
GTG. R. Tynan
G. R. Tynan
JYJ. Yin
J. Yin
XDX. R. Duan
X. R. Duan
A two-photon absorption laser induced fluorescence (TALIF) diagnostic system is designed for measuring the density of deuterium atoms in the scrape-off layer (SOL) region of the Huanliu-3 (HL-3) tokamak. The system employs laser pulses at 10 Hz with an energy of 10 mJ per pulse (pulse width <8 ns) at 205 nm. To enhance the fluorescence intensity, a semi-confocal lens was designed to achieve a relatively large solid angle for fluorescence collection. A calibration experiment was conducted, establishing the relationship between fluorescence intensity and atomic deuterium (D) density using krypton (Kr) atoms as a reference. Experimental verification of the whole TALIF system has been successfully performed in a plasma environment. The feasibility of the TALIF for the measurements of the neutral particles is discussed, and an experimental result in the HL-3 tokamak edge plasma region is shown in this paper.

1 February 2026 in AIP Advances
Verified
Journal Article
Open access
ZWZ. K. Wang
Z. K. Wang
JGJ. M. Gao
J. M. Gao
QTQ. Y. Tan
Q. Y. Tan
YDY. B. Dong
Y. B. Dong
YLY. Liu
Y. Liu
XJX. Q. Ji
X. Q. Ji
To gauge synchrotron radiation from relativistic runaway electrons during plasma disruptions, a novel wide-angle infrared periscope system has been installed and commissioned on the HL-2A tokamak. Observed along the tangent to the plasma, along the orientation of electron movement on the equatorial plane, the spectral characteristics of synchrotron radiation under typical HL-2A parameters were investigated, and the pitch angle and energy of the runaway electrons were deduced. This technique has been verified to be well suited for monitoring beams of runaway electrons with energies around 20 MeV during disruptions on the HL-2A tokamak, particularly in dedicated experiments on runaway current mitigation using supersonic molecular beam injection (SMBI) during plasma disruptions. The system is employed to track the temporal evolution of the runaway electron beam, providing direct insight into the mitigation mechanism of runaway electrons following SMBI.