Umesh Nagora

Umesh Nagora

Auto-generated profile, based on publicly available information

Umesh Nagora

Institute for Plasma Research 1 , Bhat, Gandhinagar, Gujarat 382428

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Journal of Instrumentation
Verified
Journal Article
Closed access
UNU. Nagora
U. Nagora
ASA. Sinha
A. Sinha
SPS.K. Pathak
S.K. Pathak
Pavel IvanovPavel Ivanov
Pavel Ivanov
RTR.L. Tanna
R.L. Tanna
JGJ. Ghosh
J. Ghosh


1 November 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DKDevilal Kumawat
Devilal Kumawat
KTKumudni Tahiliani
Kumudni Tahiliani
SISuresh I
Suresh I
SPS. K. Pathak
S. K. Pathak
SPSantosh P. Pandya
Santosh P. Pandya
SASuman Aich
Suman Aich
A Fast Visible Imaging Diagnostic (FVID) system, measuring the visible light emission spectrum (400–1000 nm) from tokamak plasma, has been installed on the Aditya-U tokamak to monitor the two-dimensional dynamics of the poloidal cross section of the plasma. In this work, we present the design and installation of the FVID system on the Aditya-U tokamak. The evolution of plasma and plasma–wall interactions is described. The signature of the runaway electron beam in visible imaging and its correlation with other diagnostics is presented. The estimation of the electron cyclotron resonance layer position during pre-ionization is also discussed in this work.

1 November 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
VSVarsha Siju
Varsha Siju
SPSantosh P. Pandya
Santosh P. Pandya
SPS. K. Pathak
S. K. Pathak
UNUmesh Nagora
Umesh Nagora
SPShishir Purohit
Shishir Purohit
JGJ. Ghosh
J. Ghosh
Nascent observations about the influence of kinetic instabilities on electron cyclotron emission (ECE) from runaway electrons (REs) have been detected and explored at the Aditya-Upgrade (Aditya-U) tokamak. The developed broadband ECE radiometer system offers wideband measurements by integrating several radio frequency units with a fixed intermediate frequency receiver with multiple channels, which is a novel approach to meet the needs of the localized measurements at various toroidal fields and extend the system dynamic range. The low density (ne ≤ 1 × 10−19 m−3) plasma discharges at Aditya-U are consistently accompanied by a 20%–40% increase in the ECE radiometer signal amplitude within 100 µs and sporadic step-like modulations. The Pitch Angle Scattering (PAS) of REs induced by kinetic instabilities is a potential candidate for their occurrence. This steep jump in the radiometer signals was detected due to its high temporal resolution of 10 µs. A “PREDICT” code that employs the relativistic test particle model validates these experimental findings of the radiometer diagnostic for the first time for Aditya-U tokamak. Preliminary observations of the ECE radiometer signals also show that additional gas puffs can be used to vary the trigger timings of such PAS events or even lead to their complete avoidance.

1 September 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SPS. Purohit
S. Purohit
MGM. K. Gupta
M. K. Gupta
MCMalay Bikas Chowdhuri
Malay Bikas Chowdhuri
IMI. Mansuri
I. Mansuri
MBM. Bhandarkar
M. Bhandarkar
ATAditya-U Team
Aditya-U Team
Runaway electrons (REs) are passively studied by hard x-ray (HX) emissions generated by REs. A LaBr3(Ce) detector-based HX spectroscopic diagnostic (operational within ∼75 keV to 3.5 MeV) has been set up on the ADITYA-U. The diagnostic acquisition software utility is upgraded to obtain the temporal evolution of the HX spectrum to understand the RE energy distribution in plasma during its various phases. The peak position moves to lower energy for Ohmically heated discharges (200–80 keV), indicating a relative increase in the thermal particle content in the plasma. The peak position of RE energy shows a decreasing tendency with increasing ne with Ne gas puffing and termination of the electron cyclotron resonance pulse.

1 October 2025 in Physics of Plasmas
Verified
Journal Article
Open access
SDSuman Dolui
Suman Dolui
KSKaushlender Singh
Kaushlender Singh
TMTanmay Macwan
Tanmay Macwan
SASuman Aich
Suman Aich
HRHarshita Raj
Harshita Raj
JGJ. Ghosh
J. Ghosh
Application of periodic short bursts of gas leads to periodic separation of the plasma column edge from the limiter in the Ohmically heated discharges of ADITYA-U tokamak. After every gas-puff, injecting around 1017–1018 m−3 molecules of fuel gas in the edge of the plasma column, a significant reduction in plasma density, temperature, Hα emission intensity and an increase in the Hβ/Hα ratio is observed in the vicinity of the limiter radius for a certain time duration before these parameters regain their pre-gas puff values. A decline in the ion-flux to the limiter is also observed simultaneously. The global confinement of plasma also increases after each gas-puff. These observations, which repeat after each gas-injection, imply that the plasma–neutral interaction occurs further away from the limiters after the gas-injection and indicate a periodic plasma separation from the limiter surface. Further investigation revealed that the gas-injection modifies the radial and toroidal electric field, which may be playing a role in the separation of the plasma column from the limiter surface. It was further demonstrated by an electrode bias experiment in the absence of gas-injection that an application of an external radial electric field can result in obtaining a separated plasma state.