10 January 2011 in Applied Physics Letters
We have developed a technique for defect reduction in GaN epitaxial films grown on sapphire substrates. This technique relies on the generation of high densities of embedded microvoids (∼108/cm2), a few microns long and less than a micron in diameter. These voids are located near the sapphire substrate, where high densities of dislocations are present. Network of embedded voids offer free surfaces that act as dislocation sinks or termination sites for the dislocations generated at the GaN/sapphire interface. Both transmission electron and atomic force microscopy results confirm the uniform reduction of the dislocation density by two orders of magnitude.
9 December 2020 in Advanced Science
Gamma‐rays (γ‐rays), wherever present, e.g., in medicine, nuclear environment, or homeland security, due to their strong impact on biological matter, should be closely monitored. There is a need for simple, sensitive γ‐ray detectors at affordable prices. Here, it is shown that γ‐ray detectors based on crystals of methylammonium lead tribromide (MAPbBr3) ideally meet these requirements. Specifically, the γ‐rays incident on a MAPbBr3 crystal generates photocarriers with a high mobility‐lifetime product, allowing radiation detection by photocurrent measurements at room temperatures. Moreover, the MAPbBr3 crystal‐based detectors, equipped with improved carbon electrodes, can operate at low bias (≈1.0 V), hence being suitable for applications in energy‐sparse environments, including space. The γ‐ray detectors reported herein are exposed to radiation from a 60Co source at dose rates up to 2.3 Gy h−1 under ambient conditions for over 100 h, without any sign of degradation. The excellent radiation tolerance stems from the intrinsic structural plasticity of the organic–inorganic halide perovskites, which can be attributed to a defect‐healing process by fast ion migration at the nanoscale level. The sensitivity of the γ‐ray detection upon volume is tested for MAPbBr3 crystals reaching up to 1000 cm3 (3.3 kg in weight) grown by a unique crystal growth technique.
27 April 2018 in IEEE Transactions on Nuclear Science
The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff/Λ, the effective delayed neutron fraction βeff, and the mean generation time Λ for nuclear databases and code validation efforts. A newly developed current mode detection system using two fission chambers in the core reflector was used to accurately measure the kinetic parameters of CROCUS. Characteristics of the system and the performed noise measurements are presented. We implemented noise postprocessing of the current signals acquired at 900 mW using the APSD/CPSD method. The final CPSD estimated values were found to be α = (153.3 ± 8.6) s-1, βeff = (778 ± 14) pcm, and Λ = (50.7 ± 2.9) μs. In order to comply with experimental uncertainty targets (<3%), the measurement time was 6 hours. In comparison to code predictions using MCNP5-v1.6 employing the JEFF 3.1 and ENDF/B-7.1 cross section libraries, we found differences up to 3%, confirming the need for accurate kinetic parameter measurements. In the future the new measurement system will also be used for studies of spatial and external reactor noise.
24 February 2011 in Journal of Crystal Growth
10 January 2018 in EPJ Web of Conferences
The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / λ, the effective delayed neutron fraction βeff, and the mean generation time λ for code validation efforts. At higher detection rates, i.e. above 2×104 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated 10B-coated ionization chambers available in CROCUS as operational monitors. The compensated current signal of these chambers was extracted from coremonitoring output channels. 2) By developing a new current mode amplification station to be used with other available detectors in core. Characteristics and first noise measurements of the new current system are presented. We implemented post-processing of the current signals from 1)and 2) with the APSD/CPSD method to determine α. At two critical states (0.5 and 1.5 W), using the 10B ionization chambers and their CPSD estimate, the prompt decay constant was measured after 1.5 hours to be α=(156.9 ± 4.3) s-1 (1σ). This result is within 1σ of statistical uncertainties of previous experiments and MCNPv5-1.6 predictions using the ENDF/B-7.1 library. The newsystem connected to a CFUL01 fission chamber using the APSDestimate at 100 mW after 33 min yielded α = (160.8 ± 6.3) s-1, also within 1σ agreement. The improvements to previous neutron noise measurementsinclude shorter measurement durations that can achievecomparable statistical uncertainties and measurements at higherdetection rates.