Scanning Spreading Resistance Microscopy is a well-established technique for obtaining quantitative two- and three-dimensional carrier profiles in semiconductor devices with sub-nm spatial resolution. However, for sub-100 nm devices, the use of focused ion beam becomes inevitable for exposing the region of interest on a sample cross section. In this work, we investigate the impact of the focused ion beam milling on spreading resistance analysis and we show that the electrical effect of the focused ion beam extends far beyond the amorphous region and depends on the dopant concentration, ion beam energy, impact angle, and current density. For example, for dopant concentrations between 1.0 × 1020 and 1.5 × 1016 cm−3 we observe dopant deactivation at least between 23 and 175 nm for a glancing 30 keV ion beam. Further, we show that dopant deactivation is caused by defect diffusion during milling and is not directly impacted by the presence of Gallium in the sample. Later, we also discuss potential ways to mitigate these effects.
The influence of Cr and Mo on phase formation and preferential orientation of is reported. Three different regimes are distinguished, depending on the thickness of the interlayer. For a thin interlayer or a capping layer, CoSi forms first, as in the standard Co/Si reaction. The remaining Cr or Mo can be considered as a contaminant that is present in the CoSi layer, causing a delay in nucleation and inducing preferential (220) and (400) nucleation. For interlayers with intermediate thickness, epitaxially (400) oriented is formed. For a thick interlayer, a polycrystalline layer of (or is formed first, followed by CoSi formation on top of the At higher temperatures, the CoSi layer is transformed into a polycrystalline, continuous layer of on top of the or layer, while some grains of are formed underneath the A similar behavior for Ti interlayers is observed, although a much thicker Ti layer is needed before the third regime is reached.
1 January 2010 in Journal of Vacuum Science & Technology B
With emerging three-dimensional device architectures for advanced silicon devices such as fin field-effect-transistors (FinFETs), new metrology challenges are faced to characterize dopants. The ratio of dopant concentration in the top surface and sidewalls of FinFETs may differ significantly, thereby influencing the performance of these devices. In this work, a methodology involving secondary ion mass spectrometry (SIMS) is presented to study the dose conformality in fins. However, SIMS is limited to probe the quantitative chemical dopant concentration (i.e., top/sidewall of fins). The fraction of the active dopant concentration determining the performance of FinFETs would still be unknown. Additionally, the concept based on SIMS is unable to provide information on the lateral junction depth. Thus, to obtain the unknown active dopant concentration and their spatial distribution, the authors extend their study by measuring the cross section of the fins with scanning spreading resistance microscopy and extracting the quantitative active carrier concentration in the fins.
1 January 2004 in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
In this study we demonstrate the capabilities of scanning spreading resistance microscopy (SSRM), which is an atomic force microscope based technique, for two-dimensional (2D) carrier profiling with nanometer spatial resolution, high quantification accuracy, and high concentration sensitivity. As a test vehicle we discuss the application of SSRM on devices obtained from a 90 nm node complementary metal–oxide–semiconductor technology. Transistors processed in this technology, and with poly-gate lengths down to 70 nm have been analyzed using SSRM. Dedicated quantification software has been used to calculate carrier concentration profiles. The source/drain implants and the halo- and threshold voltage adjustment implants have been analyzed for different gate sizes in order to understand their impact on the 2D channel carrier profile. The SSRM results have been compared to the results of calibrated process simulators.