4 March 2021 in IEEE Transactions on Components, Packaging and Manufacturing Technology
This article introduces the use of nickel (Ni) and copper (Cu) microfibrous meshes (MFMs) and Sorbothane and polydimethylsiloxane (PDMS) viscoelastic polymers to damp the dynamic response of a silicon micromachined vibration isolator (microisolator) for vibration reliability in mechanically harsh environments. The 9×9 mm 2 microisolator is designed to house a small, packaged MEMS sensor to be isolated from the surrounding environment. Microisolators are fabricated from <;100> silicon-on-insulator (SOI) wafers using standard lithography and deep reactive ion etching (DRIE) procedures. The MFMs are attached to the microisolators post-fabrication via solder attachment. We then investigate the transmissibility of the undamped and damped vibration microisolators using laser Doppler vibrometry. The peak transmissibility of the microisolator is significantly reduced for all four cases of polymer or MFM damping. Experimental results are compared to the FEA simulated transmissibility and the analytically calculated transmissibility.
14 October 2019 in IEEE Transactions on Components, Packaging and Manufacturing Technology
This paper details the design, simulation, fabrication, and testing of four variations of micromachined vibration isolators. The vibration isolators serve as low pass filters to attenuate high frequency (>2 kHz) mechanical excitation in order to improve both MEMS sensor fidelity and lifespan. Isolators are designed for integration with a small (∼3mm × ∼3mm) MEMS sensor package and boast a sub-1 cm2 footprint (7mm × 7mm). For all isolator variations, the fundamental geometry consists of an outer frame to be fixed to the substrate of interest, a central platform to accommodate the isolated sensor, and springs for attachment of the frame and platform. We fabricate devices via a simple, double-sided lithography process using < 100 > silicon-on-insulator (SOI) wafers. We then performed laser Doppler vibrometry to investigate the frequency response of each isolator variation across a 6.2 kHz bandwidth. Dependent upon geometry, isolator variations exhibit resonant frequencies from 1.3 kHz to 2 kHz with quality factors (Qs) ranging from 16.7 to 60.
29 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.