Rezki El Arif

Rezki El Arif

Auto-generated profile, based on publicly available information

Rezki El Arif

Department of Biomedical Engineering, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WSWei-Chih Su
Wei-Chih Su
YLYi-Chen Lai
Yi-Chen Lai
THTzyy-Sheng Horng
Tzyy-Sheng Horng
RARezki El Arif
Rezki El Arif
This article presents a time-division multiplexing (TDM) multiple-input–multiple-output (MIMO) radar system that differs from existing ones by incorporating a heterodyne self-injection-locking (HSIL) architecture for enhanced Doppler sensitivity. The system operates in the unlicensed 6-GHz band and produces the 3-D images of multiple individuals, enabling the identification of the hotspot on a person’s chest where the maximum echo amplitude occurs. This approach allows for the accurate and reliable measurement of vital signs, despite variations in body posture and orientation. Quantitatively, the system can detect a minimum amplitude of vibration of 15 $\mu $ m for a 10 $\times$ 10 cm metal plate placed 1.5 m away. A Doppler-weighted super-resolution technique helps to distinguish between the images that are generated by two metal plates of equal size and separated by less than the theoretical range and angular resolution limit of 15 cm and 14 $^{\circ}$ , respectively. Consequently, the system effectively detected the vital signs of three subjects with varying body postures and orientations by locating the hotspots in their respective images, demonstrating its potential for practical applications.

14 March 2022 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
RARezki El Arif
Rezki El Arif
WSWei-Chih Su
Wei-Chih Su
THTzyy-Sheng Horng
Tzyy-Sheng Horng
This article presents a chest-worn device for monitoring the heart rate variability (HRV) of a person in motion without direct contact with the skin. The device operates at 5.8 GHz and mainly consists of a self-injection-locked oscillator (SILO) and a tag antenna. The device transmits the output signal of an SILO that is frequency-modulated (FM) by the Doppler effect of the physiological movement of the chest via the tag antenna to a remote FM receiver. Accordingly, the heartbeat is detected and the HRV can be estimated. The tag antenna comprises a circularly polarized ring slot antenna and a split-ring resonator (SRR) array in stack to enhance sensing directivity while reducing the moving clutter in the joint sensing and transmission process. For validation, an HRV monitoring system was developed, based on the proposed device, to detect the cardiac intervals of a wearer who performs various activities, including walking and running. The results thus obtained agree closely with electrocardiogram (ECG) measurements.

2 January 2023 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
RARezki El Arif
Rezki El Arif
THTzyy-Sheng Horng
Tzyy-Sheng Horng
This letter presents a heart sound monitoring system with a chest-worn sensor without contact with the skin. A self-injection-locked oscillator (SILO) and tag antenna are the essential components of the sensor, which operates at 5.8 GHz. The sensor uses the tag antenna to transmit the SILO output signal whose frequency is modulated by the Doppler effect that is caused by the chest movement, to a remote frequency modulation (FM) receiver for extracting the heart sounds. The tag antenna comprises a loop antenna and a concentric loop (CL) in a stack to improve the directivity toward the chest. Experiments were conducted at several auscultation sites to identify the four major heart sounds—the first heart sound (S1), the second heart sound (S2), systole, and diastole—based on a hidden semi-Markov model (HSMM). The results thus obtained correlate well with phonocardiogram (PCG) measurements.

16 January 2024 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Open access
RARifa Atul Izza Asyari
Rifa Atul Izza Asyari
KLKuan-Yuan Lee
Kuan-Yuan Lee
RARezki El Arif
Rezki El Arif
THTzyy-Sheng Jason Horng
Tzyy-Sheng Jason Horng
DTDaniel Teichmann
Daniel Teichmann
This study introduces a novel method employing adaptable transmitarray lenses for medical radar systems, enhancing the direction of electromagnetic beams in the far-field. The newly developed antenna array exhibited marked improvements in gain, bandwidth, return loss, and isolation within specific frequency ranges during testing. Comprehensive evaluations, including various focal lengths and bending scenarios, underscored the superior performance of this adaptable lens over prior techniques. Its exceptional precision and sensitivity render it an ideal tool for real-time remote health monitoring systems, particularly in pulse detection. The research findings consistently aligned the heart rates detected by this innovative method with standard reference rates, reaffirming its reliability and accuracy. This consistency highlights the potential of the transmitarray lenses as a valuable advancement in medical radar systems. The study not only validates the effectiveness and reliability of the lenses but also lays a solid foundation for further research and development in this field. The insights garnered are expected to significantly bolster the progression of radar technologies in healthcare, leading to more accurate, efficient, and non-invasive health monitoring solutions, thereby enhancing patient care and outcomes.

18 March 2026 in IEEE Access
Verified
Journal Article
Open access
FRFirdausa Sonna Anggara Resta
Firdausa Sonna Anggara Resta
RSRachmad Setiawan
Rachmad Setiawan
MRMuhammad Rivai
Muhammad Rivai
RARezki El Arif
Rezki El Arif
ANAzis Natawijaya
Azis Natawijaya
AHAfan Ghafar Al Hadad
Afan Ghafar Al Hadad
This work presents a multimodal radar-vision framework for non-destructive ripeness classification of oil palm fresh fruit bunches (FFBs) under field conditions. A continuous wave 2.4 GHz radar and a digital scale capture backscattered power and bunch mass as internal cues related to dielectric properties and growth, while RGB images provide external color and texture information. Radar-weight features (power, weight, and power-to-weight ratio) are modeled using an extreme gradient boosting (XGBoost) classifier, and a YOLOv8-Nano detector is trained using an expert-annotated RGB dataset to localize and classify bunches into four maturity stages (Unripe, Underripe, Ripe, Overripe). Decision-level late fusion combines the class-probability outputs of both branches through mean, weighted, and stacking schemes. Experiments on radar-weight data (255 samples per class) acquired at a commercial loading ramp show that the unimodal radar-weight and vision models reach 89.9% and 94.3% accuracy, respectively, with YOLOv8-Nano achieving mAP@0.5 of 0.99. The best fusion configuration, based on stacking, attains 96.9% accuracy and 97.3% F1-macro, demonstrating that radar-weight information provides complementary evidence that stabilizes vision-based grading and supports more consistent harvest decisions.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
NANadiya Azka
Nadiya Azka
RSRachmad Setiawan
Rachmad Setiawan
TSTri Arief Sardjono
Tri Arief Sardjono
Han MoshageHan Moshage
Han Moshage
RARezki El Arif
Rezki El Arif