Wei-Chih Su

Wei-Chih Su

Auto-generated profile, based on publicly available information

Wei-Chih Su

Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WSWei-Chih Su
Wei-Chih Su
MTMu-Cyun Tang
Mu-Cyun Tang
RARezki El Arif
Rezki El Arif
THTzyy-Sheng Horng
Tzyy-Sheng Horng
FWFu-Kang Wang
Fu-Kang Wang
This article proposes a single-conversion stepped-frequency continuous-wave (SCSFCW) radar that combines a stepped-frequency continuous-wave (SFCW) radar and a self-injection-locked (SIL) radar to benefit from the range resolution and the Doppler sensitivity of the two radars. An 8.5-9.5-GHz prototype SCSFCW radar system that comprises a subharmonic up/down converter with a 3-3.5-GHz stepped chirp local-oscillator (LO) signal and a 2.5-GHz SIL IF signal was developed to monitor the vital signs, i.e., respiration rate (RR) and heart rate (HR), of multiple humans. The coherence and range of the developed system were significantly enhanced by using a low pulse repetition frequency (PRF). In the experiment, the minimum distinguishable radial spacing between the vibrating frequencies of the metal plates that are not azimuthally overlapped with one another corresponds to a theoretical range resolution of 15 cm. However, owing to scattering by the human body, the minimum radial spacing for distinguishing between the vital signs of the individuals is three times than that for distinguishing between the metal plates in a similar experimental setup. Accordingly, the monitoring of up to three human vital signs using the developed system was demonstrated with a range-vital-Doppler map.

4 December 2020 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WSWei-Chih Su
Wei-Chih Su
PJPin-Hsun Juan
Pin-Hsun Juan
DCDe-Ming Chian
De-Ming Chian
THTzyy-Sheng Jason Horng
Tzyy-Sheng Jason Horng
CWChao-Kai Wen
Chao-Kai Wen
FWFu-Kang Wang
Fu-Kang Wang
This article presents the combination of a self-injection-locked (SIL) radar with frequency-modulated continuous-wave (FMCW) and switched phased-array (SPA) techniques to locate multiple people and detect their vital signs with high resolution and high sensitivity. The proposed system utilizes a subharmonic upconverter/downconverter with a 1.675-2.175-GHz chirp local oscillator (LO) signal to convert between a 2.45-GHz SIL IF signal and a 5.8-6.8-GHz FMCW RF signal. It transmits the FMCW RF signal and receives the echo signal using a transmit (Tx) antenna and a switched receive (Rx) antenna array, respectively, and processes the SIL IF signal to produce a range-azimuth map (RAM) that displays the positions of all people, their respiration rates (RRs), and their heart rates (HRs) in the monitoring region. The key advantage of combining the FMCW and SPA techniques is the provision of higher spatial resolution than obtained using each technique alone. This article also proposes a Doppler-weighted RAM to improve the identifiability of the images that are generated by two persons close to each other. Finally, the presented system was experimentally validated by measuring the locations and vital signs of up to five seated persons at a range of more than 1.5 m, of which two persons were seated almost shoulder by shoulder.

4 July 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
YLYu-Xiang Lin
Yu-Xiang Lin
ZAZohauddin Ahmad
Zohauddin Ahmad
SOSung-Yi Ou
Sung-Yi Ou
WSWei-Chih Su
Wei-Chih Su
YCYan-Chieh Chang
Yan-Chieh Chang
Jin-wei ShiJin-wei Shi
Jin-wei Shi
This work presents a novel scheme for a 4-dimensional (D) frequency modulated continuous wave (FMCW) LiDAR, which demonstrates an unprecedentedly high velocity sensitivity. This is achieved by utilizing the driving waveform to minimize the phase noise originating from the distributed feedback (DFB) laser during the wavelength sweeping process on the transmitting side, while on the receiving end, we use a combination of a self-injection-locked oscillator (SILO) and an avalanche photodiode (APD) with a cascaded multiplication layer, to ensure excellent responsivity and saturation current performance. Comparison is made with a reference LiDAR system comprised of the traditional radio-frequency (RF) oscillator with a p-i-n PD at the receiving-end. The results show that our SILO + APD design provides much better quality 4-D images of slow-moving objects (5 μm/sec) and state-of-the-art velocity sensitivity. This can be attributed to a reduction in the phase noise of the down-converted baseband signals, which is beneficial to the resolution of a small Doppler frequency shift. Furthermore, the incorporation of a high-performance APD also improves the contrast ratio between the object and the background pixels. These improvements offer new possibilities for the development of the next generation of 4-D FMCW LiDARs capable of simultaneously providing the absolute 3-D geometric size and small vibration information.

26 January 2022 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WSWei-Chih Su
Wei-Chih Su
XWXuan-Xin Wu
Xuan-Xin Wu
THTzyy-Sheng Horng
Tzyy-Sheng Horng
MTMu-Cyun Tang
Mu-Cyun Tang
This article presents a novel monopulse radar that combines high-sensitivity continuous-wave (CW) and self-injection-locking (SIL) receivers to detect and localize the movements in a human body. The proposed radar utilizes a CW sum pattern and an SIL difference pattern to process the echo signal from the target, so it can produce a monopulse ratio to estimate the angle of arrival (AoA) of the echo signal. With this capability, the radar can localize the movements on the target’s chest that are caused by vital signs such as respiration and heartbeat for posture classification. In addition, the radar can be used in a fall alarm as it can detect a change of posture during a fall. As a proof of concept, a 2.4-GHz prototype radar was experimentally implemented to validate the robustness of detecting falls regardless of their direction.

6 September 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WSWei-Chih Su
Wei-Chih Su
YLYi-Chen Lai
Yi-Chen Lai
THTzyy-Sheng Horng
Tzyy-Sheng Horng
RARezki El Arif
Rezki El Arif
This article presents a time-division multiplexing (TDM) multiple-input–multiple-output (MIMO) radar system that differs from existing ones by incorporating a heterodyne self-injection-locking (HSIL) architecture for enhanced Doppler sensitivity. The system operates in the unlicensed 6-GHz band and produces the 3-D images of multiple individuals, enabling the identification of the hotspot on a person’s chest where the maximum echo amplitude occurs. This approach allows for the accurate and reliable measurement of vital signs, despite variations in body posture and orientation. Quantitatively, the system can detect a minimum amplitude of vibration of 15 $\mu $ m for a 10 $\times$ 10 cm metal plate placed 1.5 m away. A Doppler-weighted super-resolution technique helps to distinguish between the images that are generated by two metal plates of equal size and separated by less than the theoretical range and angular resolution limit of 15 cm and 14 $^{\circ}$ , respectively. Consequently, the system effectively detected the vital signs of three subjects with varying body postures and orientations by locating the hotspots in their respective images, demonstrating its potential for practical applications.

14 March 2022 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
RARezki El Arif
Rezki El Arif
WSWei-Chih Su
Wei-Chih Su
THTzyy-Sheng Horng
Tzyy-Sheng Horng
This article presents a chest-worn device for monitoring the heart rate variability (HRV) of a person in motion without direct contact with the skin. The device operates at 5.8 GHz and mainly consists of a self-injection-locked oscillator (SILO) and a tag antenna. The device transmits the output signal of an SILO that is frequency-modulated (FM) by the Doppler effect of the physiological movement of the chest via the tag antenna to a remote FM receiver. Accordingly, the heartbeat is detected and the HRV can be estimated. The tag antenna comprises a circularly polarized ring slot antenna and a split-ring resonator (SRR) array in stack to enhance sensing directivity while reducing the moving clutter in the joint sensing and transmission process. For validation, an HRV monitoring system was developed, based on the proposed device, to detect the cardiac intervals of a wearer who performs various activities, including walking and running. The results thus obtained agree closely with electrocardiogram (ECG) measurements.