Karen Junius

Karen Junius

Auto-generated profile, based on publicly available information

Karen Junius

Mechanical Engineering Department, Vrije Universiteit Brussel, Pleinlaan 2, Brussels 1050, Belgium

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Applied Mechanics Reviews
Verified
Journal Article
Closed access
PDF file
MNMatthias B. Näf
Matthias B. Näf
KJKaren Junius
Karen Junius
MRMarco Rossini
Marco Rossini
CGCarlos Rodriguez Guerrero
Carlos Rodriguez Guerrero
Bram VanderborghtBram Vanderborght
Bram Vanderborght
DLDirk Lefeber
Dirk Lefeber
The use of exoskeletons by the elderly, disabled people, heavy labor workers, and soldiers can have great social and economic benefit. However, limitations in usability are impeding the widespread adoption of exoskeletal devices. Kinematic compatibility, comfort, volume, mass, simplicity, expandability, and the ability to transmit forces, relative angles between the exoskeleton and the human, and the donning and doffing procedure need to be considered. Over the last decades, a large number of exoskeletons have been developed, to assert kinematic compatibility and compensate for misalignment. To such a degree, that it has become difficult to keep an overview of the different strategies. Therefore, this review article presents an extensive overview of different misalignment compensation strategies existing in the literature. Further, these strategies are organized in nine categories, evaluated and discussed around the exoskeleton's application domain and its specific requirements and needs.

8 November 2017 in Bioinspiration & Biomimetics
Verified
Journal Article
Closed access
PDF file
KJKaren Junius
Karen Junius
MMMarta Moltedo
Marta Moltedo
PCPierre Cherelle
Pierre Cherelle
CGCarlos Rodriguez Guerrero
Carlos Rodriguez Guerrero
BVBram Vanderborght
Bram Vanderborght
DLDirk Lefeber
Dirk Lefeber
Despite the increased interest in exoskeleton research in the last decades, not much progress has been made on the successful reduction of user effort. In humans, biarticular elements have been identified as one of the reasons for the energy economy of locomotion. This document gives an extensive literature overview concerning the function of biarticular muscles in human beings. The exact role of these muscles in the efficiency of human locomotion is reduced to three elementary functions: energy transfer towards distal joints, efficient control of output force direction and double joint actuation. This information is used to give an insight in the application of biarticular elements in bio-inspired robotics, i.e. bipedal robots, exoskeletons, robotic manipulators and prostheses. Additionally, an attempt is made to find an answer on the question whether the biarticular property leads to a unique contribution to energy efficiency of locomotion, unachievable by mono-articular alternatives. This knowledge is then further utilised to indicate how biarticular actuation of exoskeletons can contribute to an increased performance in reducing user effort.

1 May 2017 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
PCPierre Cherelle
Pierre Cherelle
VGVictor Grosu
Victor Grosu
LFLouis Flynn
Louis Flynn
KJKaren Junius
Karen Junius
MMMarta Moltedo
Marta Moltedo
DLDirk Lefeber
Dirk Lefeber

1 January 2017 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
KJKaren Junius
Karen Junius
MDMarc Degelaen
Marc Degelaen
NLNina Lefeber
Nina Lefeber
ESEva Swinnen
Eva Swinnen
BVBram Vanderborght
Bram Vanderborght
DLDirk Lefeber
Dirk Lefeber
A shared design goal for most robotic lower limb exoskeletons is to reduce the metabolic cost of locomotion for the user. Despite this, only a limited amount of devices was able to actually reduce user metabolic consumption. Preservation of the natural motion kinematics was defined as an important requirement for a device to be metabolically beneficial. This requires the inclusion of all human degrees of freedom (DOF) in a design, as well as perfect alignment of the rotation axes. As perfect alignment is impossible, compensation for misalignment effects should be provided. A misalignment compensation mechanism for a 3-DOF system is presented in this paper. It is validated by the implementation in a bilateral hip exoskeleton, resulting in a compact and lightweight device that can be donned fast and autonomously, with a minimum of required adaptations. Extensive testing of the prototype has shown that hip range of motion of the user is maintained while wearing the device and this for all three hip DOFs. This allowed the users to maintain their natural motion patterns when they are walking with the novel hip exoskeleton.

20 September 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KJKaren Junius
Karen Junius
NLNina Lefeber
Nina Lefeber
ESEva Swinnen
Eva Swinnen
Bram VanderborghtBram Vanderborght
Bram Vanderborght
DLDirk Lefeber
Dirk Lefeber
Objective: Show the benefit of kinematically compatible joint structures in exoskeletons for improving their performance in reducing metabolic consumption. Methods: Subjects were fitted with a hip exoskeleton, with misalignment compensation for all degrees of freedom and were instructed to perform recurring sit-to-stand motions for 5 min. This was executed three times: Unequipped (i.e., not wearing the exoskeleton), assisted, and unassisted. During each trial, oxygen consumption and muscle activity were monitored. Results: An increased oxygen consumption was observed between the unequipped and the unassisted trial. During the assisted trial, oxygen consumption was reduced to levels seen in the unequipped state. Muscle activity increased for rectus femoris and tibialis anterior and decreased for biceps femoris and gluteus maximus. Conclusion: Oxygen consumption only increases in accordance with the added mass. No added penalty was seen related to increased inertia or hindrance of natural motion patterns. This indicates that the mechanism operates as intended. The increased muscle activity can be explained by the nature of the actuation system, which is not optimized for sit-to-stand tasks. A more targeted actuation system can easily reduce muscle activity, and therefore, induce a reduced oxygen consumption, below unequipped levels. Significance: Because the benefits induced by using these systems are independent of user capabilities or deficiencies, it is applicable in a wide range of exoskeleton applications. The design presented here, allows for the realization of compact and light devices, that have a minimal impact on the metabolic cost of their user. This allows to maximally exploit the metabolically beneficial effects of a well-designed actuation system.

13 October 2016
Verified
Book Chapter
Closed access
PDF file
DLDirk Lefeber
Dirk Lefeber
MMMarta Moltedo
Marta Moltedo
TBTomislav Bacek
Tomislav Bacek
Kevin LangloisKevin Langlois
Kevin Langlois
KJKaren Junius
Karen Junius
Bram VanderborghtBram Vanderborght
Bram Vanderborght