21 January 2025 in IEEE Transactions on Applied Superconductivity
In this article, we present a newly developed continuous thickness measurement system for long-length high-temperature superconducting (HTS) coated conductors (CCs). Uniform thickness in HTS CCs is critical for maintaining consistent magnetic field performance and mechanical integrity, particularly in applications such as superconducting coil windings. Our system employs a reel-to-reel (R2R) mechanism integrated with confocal laser sensors to enable real-time, non-contact thickness measurements. Comprehensive trials were carried out to evaluate the system's accuracy and precision, including static scans at various speeds and comparisons with cross-sectional analysis using optical microscopy. Additionally, the system demonstrated high precision, with repeatability confirmed through 10 repeated measurements along the length and width of a 12 m-long Cu-plated HTS CC. This development is expected to significantly improve the manufacturing process, enhance quality control, and support factory automation for consistent production of high-performance HTS magnets.
5 November 2025 in IEEE Transactions on Applied Superconductivity
Geometric uniformity is crucial for high-temperature superconducting (HTS) REBCO coated conductors (CCs), particularly in superconducting-magnet applications that demand precise winding geometries. A non-contact, continuous reel-to-reel (R2R) thickness measurement system was implemented in this study to systematically examine thickness profiles at key manufacturing stages, including raw metal substrates, electro polishing (EP), buffer layer deposition, superconducting layer and silver (Ag) deposition, tape slitting, and copper (Cu) electroplating. Static and continuous R2R scanning analyses revealed significant geometric deformations, such as edge tapering caused by asymmetric EP and pronounced edge thickening (so called “dog-bone” shape) due to non-uniform electroplating fields. To mitigate these geometric non-uniformities, advanced strategies adaptive deposition based on real-time thickness mapping, precise field distribution shielding during electroplating, and automated roller gap feedback controls are proposed. Implementing these measures is expected to enhance geometric consistency, improve manufacturing yield, and enable robust quality control for high-performance REBCO CCs.
1 August 2026 in IEEE Transactions on Applied Superconductivity
High-temperature superconducting (HTS) coils are widely studied for their applicability in high-field applications, and the use of cryocoolers for coil cooling is becoming increasingly common. Since the thermal stability of a coil cooled by a cryocooler depends on its thermal performance, achieving high thermal performance in the coil has emerged as a critical issue. No insulation HTS coils exhibit improved thermal performance, but the dry contact between turns increases thermal resistance and limits radial heat transfer. In previous research, the authors proposed a method to enhance the radial thermal performance of HTS coils by winding them with superconducting wires featuring an Ag outermost layer and performing heat treatment to achieve Ag diffusion bonding, thereby eliminating turn-to-turn dry contact. However, cross sectional analysis revealed that complete diffusion bonding was not achieved between turns in the coil structure. In this paper, a study was conducted to improve the degree of turn-to-turn diffusion bonding in the coil and enhance its radial thermal performance. To improve the degree of turn-to-turn diffusion bonding, HTS coils with diffusion bonding were fabricated under various winding tension conditions. To evaluate the radial thermal performance of the coils, the radial thermal conductivity was measured at different temperatures. Additionally, cross sectional analyses of the fabricated coils were conducted to assess the effect of winding tension on the degree of turn-to-turn diffusion bonding and radial thermal conductivity. The results indicate that increasing the winding tension during coil fabrication enhances the degree of turn-to-turn diffusion bonding and improves the radial thermal conductivity. These findings can be utilized to enhance the thermal stability of HTS coils.