Usman Ali

Usman Ali

Auto-generated profile, based on publicly available information

Usman Ali

Department of Telecommunication Engineering, University of Engineering and Technology, Mardan, Pakistan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2019 in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
Verified
Journal Article
Closed access
PDF file
UAUsman Ali
Usman Ali
Sadiq UllahSadiq Ullah
Sadiq Ullah
MSMuhammad Shafi
Muhammad Shafi
SSSyed A.A. Shah
Syed A.A. Shah
ISIzaz A. Shah
Izaz A. Shah
JFJames A. Flint
James A. Flint

17 July 2023 in IEEE Access
Verified
Journal Article
Open access
UAUsman Ali
Usman Ali
Sadiq UllahSadiq Ullah
Sadiq Ullah
ABAbdul Basir
Abdul Basir
BKbabar kamal
babar kamal
Ladislau MatekovitsLadislau Matekovits
Ladislau Matekovits
HYHyoungsuk Yoo
Hyoungsuk Yoo
This study designed and analyzed an artificial magnetic conductor (AMC)-based fabric antenna for body-centric communication. The antenna was made of felt and had a loss tangent of 0.044 and relative permittivity of 1.3. The proposed antenna was built to function in the frequency band centered at 2.45 GHz, widely used in wireless communication devices. The antenna’s performance was evaluated using the electromagnetic simulation software CST MWS. A 50 Ω SubMiniature version connector was used to excite the proposed antenna. A 2 × 2 AMC array was integrated into the antenna below it to improve its performance in terms of radiation efficiency, gain, and backward radiation reduction. The antenna and AMC array were fabricated on flexible fabric substrates. The total volume of the AMC-integrated antenna is 0.55λ 0 × 0.55λ 0 × 0.016λ 0 . It was demonstrated that adding an AMC array enhanced the radiation properties of the antenna and significantly decreased its back lobes. The on- and off-body maximum gains of the AMC-integrated antenna are (≥ 4.11 dBi) and 5.23 dBi, respectively. Furthermore, employing the AMC array, a significant reduction in the specific absorption rate value, which is (≤ 0.43 W/kg) for human body tissue chest/back and (≤ 0.75 W/kg) for human body tissue arm, was obtained, ensuring safety for human use. The simulated and measured results were in agreement. The tested on- and off-body radiation efficiencies in the frequency band centered at 2.45 GHz is (>67%) and (>83%), respectively. The proposed antenna can potentially be used in various applications such as healthcare monitoring, wearable electronics, and Internet of Things (IoT) systems, where reliable and efficient communication is required in a body-centric environment.

11 July 2023 in IEEE Access
Verified
Journal Article
Open access
UAUsman Ali
Usman Ali
ABAbdul Basir
Abdul Basir
MZMuhammad Zada
Muhammad Zada
Sadiq UllahSadiq Ullah
Sadiq Ullah
BKbabar kamal
babar kamal
HYHyoungsuk Yoo
Hyoungsuk Yoo
The increasing demand for wireless communication in wearable devices has led to the need for wearable antennas with a low profile, flexibility, robustness, low SAR, and acceptable on-body performance for WBAN applications. This study presents a low-profile dual-band wearable antenna for WBAN applications operating at 2.45 and 5.8 GHz. The antenna is integrated with a 3 × 3 artificial magnetic conductor array to reduce backward radiation and improve performance when worn on the human body. It is designed and fabricated on a 2 mm-thick flexible felt substrate with a relative permittivity of 1.3 and loss tangent of 0.044. A 0.17 mm-thick superconductive shielded material is used as conductive material for the antenna and AMC array. The proposed antenna and AMC array have overall volumes of 0.41λ 0 × 0.45λ 0 × 0.016λ 0 and 0.83λ 0 × 0.83λ 0 × 0.016λ 0 , respectively. Results indicate that the AMC structure enhances the antenna’s gain, radiation efficiency, and bandwidth. The use of AMC reduced the SAR by greater than 98% for 1 and 10 g of human tissue at 2.45 and 5.8 GHz. The proposed design is suitable for WBAN applications due to its low profile, flexibility, robustness, low SAR, and acceptable on-body antenna gain and bandwidth.

27 September 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SUSami Ullah
Sami Ullah
UAUsman Ali
Usman Ali
Muhammad RashidMuhammad Rashid
Muhammad Rashid
Saif HaiderSaif Haider
Saif Haider
Ozgur KisiOzgur Kisi
Ozgur Kisi
MMMohamed A. Mattar
Mohamed A. Mattar
The study investigates the interplay of land use dynamics and climate change on the hydrological regime of the Ravi River using a comprehensive approach integrating Geographic Information System (GIS), remote sensing, and hydrological modeling at the catchment scale. Employing the Soil and Water Assessment Tool (SWAT) model, simulations were conducted to evaluate the hydrological response of the Ravi River to both current conditions and projected future scenarios of land use and climate change. This study differs from previous ones by simulating future land use and climate scenarios, offering a solid framework for understanding their impact on river flow dynamics. Model calibration and validation were performed for distinct periods (1999–2002 and 2003–2005), yielding satisfactory performance indicators (NSE, R2, PBIAS = 0.85, 0.83, and 10.01 in calibration and 0.87, 0.89, and 7.2 in validation). Through supervised classification techniques on Landsat imagery and TerrSet modeling, current and future land use maps were generated, revealing a notable increase in built-up areas from 1990 to 2020 and projections indicating further expansion by 31.7% from 2020 to 2100. Climate change projections under different socioeconomic pathways (SSP2 and SSP5) were derived for precipitation and temperature, with statistical downscaling applied using the CMhyd model. Results suggest substantial increases in precipitation (10.9 − 14.9%) and temperature (12.2 − 15.9%) across the SSP scenarios by the end of the century. Two scenarios, considering future climate conditions with current and future land use patterns, were analyzed to understand their combined impact on hydrological responses. In both scenarios, inflows to the Ravi River are projected to rise significantly (19.4 − 28.4%) from 2016 to 2100, indicating a considerable alteration in seasonal flow patterns. Additionally, historical data indicate a concerning trend of annual groundwater depth decline (0.8 m/year) from 1996 to 2020, attributed to land use and climate changes. The findings underscore the urgency for planners and managers to incorporate climate and land cover considerations into their strategies, given the potential implications for water resource management and environmental sustainability.

9 December 2024 in IEEE Access
Verified
Journal Article
Open access
MAMuhammad Abbas
Muhammad Abbas
SKSami Ullah Khan
Sami Ullah Khan
MAMuhammad Aamir
Muhammad Aamir
NKNasir Ullah Khan
Nasir Ullah Khan
UAUsman Ali
Usman Ali
TBToni Björninen
Toni Björninen
A remote healthcare system allows patients to be monitored and diagnosed at home; however, a reliable wireless link is essential to make it possible. This study proposes a miniaturized implantable antenna resonating at 401-406 MHz, medical implant communication service band. The proposed implantable antenna has a 12 mm × 12 mm × 0.64 mm (92.16 mm 3 ) compact footprints and is fabricated on a biocompatible Roger R03010 material. To improve the safety, superstrate and a silicon coating around the antenna are employed to completely insulate the antenna from the surrounding tissues. The finite difference time domain and finite-element methods were utilized to optimize and simulate the proposed antenna, followed by fabrication and testing. For better validation, simulations of the proposed implantable antenna, including reflection coefficient, gain, and scattering parameters were performed within a three-layer body phantom while the measurements were conducted inside minced pork. The developed prototype of the implantable antenna exhibits 74MHzmeasured bandwidth and -31.6 dBi measured gain at 402 MHz. Further, the specific absorption rate analyses were performed for safety concerns and found to be within the standard limits. Both the simulated and measured results exhibit good agreements, with the overall performance reaching the state-of-the-art.

30 April 2025 in IEEE Open Journal of Antennas and Propagation
Verified
Journal Article
Open access
SKSami Ullah Khan
Sami Ullah Khan
MAMuhammad Aamir
Muhammad Aamir
MAMuhammad Abbas
Muhammad Abbas
UAUzman Ali
Uzman Ali
UAUsman Ali
Usman Ali
TBToni Björninen
Toni Björninen
In this paper, a miniaturized implantable antenna is designed for biomedical applications operating within the industrial, scientific, and medical band (ISM, 2.4–2.48 GHz). The proposed implantable antenna has a compact size of 5.5 × 5.5 × 0.64 mm and is manufactured using a biocompatible substrate, Roger RO3010 with permittivity of εr=10.2 and losstangentof tan(δ)=0.0022. To enhance safety, a superstrate and a silicon coating around the antenna are employed to isolate the antenna from the surrounding biological tissues. The simulation software from the HFSS and CST studio suite was utilized to simulate and optimize the proposed implantable antenna, followed by fabrication and testing. The simulation of the proposed antenna was evaluated in terms of its reflection coefficient and gain within a three-layered body phantom, while the testing of the proposed design was carried out using minced pork. The proposed implantable antenna exhibits an 811 MHz bandwidth and a –21 dBi measured gain at 2.45 GHz. Furthermore, for safety evaluation, the specific absorption rate (SAR) analysis was conducted and was found to be within standard limits. The simulated and measured results show a strong correlation, demonstrating that the antenna delivers state-of-the-art performance for implantable biomedical applications.