State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BLBoyu Li
Boyu Li
ZHZhiguo Hao
Zhiguo Hao
SLSimeng Li
Simeng Li
SPShuyan Pan
Shuyan Pan
JXJunhui Xiong
Junhui Xiong
BZBaohui Zhang
Baohui Zhang
In recent years, many accidents occurred worldwide owing to Buchholz relay maloperation and failure to act in time, which significantly compromised the security of power systems. To address this problem, an experiment based on a 25 MVA/110 kV oil-immersed power transformer setup was performed to characterize the response of a Buchholz relay; gas-generation faults of different severity inside the transformer's oil tank were simulated by controlling the pressure and volume of injected gas. The experimental results reveal that the gas accumulation relay has high sensitivity but insufficient speediness. Further, the oil surge relay is relatively fast but low in sensitivity, whose action threshold is affected by static pressure difference. Based on the different characteristics of non-electric parameters under internal and external faults, a digital non-electric parameter protection method, which exhibits good performance, is devised. The findings of this study can lay the foundation for optimizing the design and evaluation of the Buchholz relay, and for developing non-electric parameter protection devices.

15 December 2021
Verified
Conference Paper
Closed access
YZYucheng Zhang
Yucheng Zhang
ZHZhiguo Hao
Zhiguo Hao
YZYuping Zheng
Yuping Zheng
SPShuyan Pan
Shuyan Pan
BLBoyu Li
Boyu Li
JDJinzhao Deng
Jinzhao Deng
Light gas protection only operates when gas within the transformer collection chamber reaches threshold volume. Such criterion failed to reflect transformer conditions accurately due to the lack of understanding for defect developing process and corresponding gas generation- convergence pattern, which has led to lower protection reliability and has caused several transformer explosions. To address current problem, an experimental tank with structure resembling that of a power transformer is set up, inside which the needle-plate oil-pressboard breakdown model is planted. Experimental results indicate that throughout fault development, voltage drops became more frequent until arcing occurs, so is HFCT signal; meanwhile gas generation rate increases through slight partial discharge, spark discharge and arcing stage, the collected gas volume corresponds with patterns above. The purpose of this study is to clarify the defect developing process and the gas generation-convergence pattern for oil-immersed transformer internal fault in guidance for a more reliable protection method.