Simeng Li

Mr. Simeng Li

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
YJYunfei Jia
Yunfei Jia
XLXun Luo
Xun Luo
SJShengchang Ji
Shengchang Ji
WGWanjing Gao
Wanjing Gao
SLSimeng Li
Simeng Li
FZFan Zhang
Fan Zhang

3 October 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BLBoyu Li
Boyu Li
ZHZhiguo Hao
Zhiguo Hao
SLSimeng Li
Simeng Li
SPShuyan Pan
Shuyan Pan
JXJunhui Xiong
Junhui Xiong
BZBaohui Zhang
Baohui Zhang
In recent years, many accidents occurred worldwide owing to Buchholz relay maloperation and failure to act in time, which significantly compromised the security of power systems. To address this problem, an experiment based on a 25 MVA/110 kV oil-immersed power transformer setup was performed to characterize the response of a Buchholz relay; gas-generation faults of different severity inside the transformer's oil tank were simulated by controlling the pressure and volume of injected gas. The experimental results reveal that the gas accumulation relay has high sensitivity but insufficient speediness. Further, the oil surge relay is relatively fast but low in sensitivity, whose action threshold is affected by static pressure difference. Based on the different characteristics of non-electric parameters under internal and external faults, a digital non-electric parameter protection method, which exhibits good performance, is devised. The findings of this study can lay the foundation for optimizing the design and evaluation of the Buchholz relay, and for developing non-electric parameter protection devices.

8 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
WSWen Si
Wen Si
SLSimeng Li
Simeng Li
HXHuaishuo Xiao
Huaishuo Xiao
QLQing-quan Li
Qing-quan Li
YSYalin Shi
Yalin Shi
TZTongqiao Zhang
Tongqiao Zhang
The ultra high voltage direct current (UHVDC) transmission system has advantages in delivering electrical energy over long distance at high capacity. UHVDC converter transformer is a key apparatus and its insulation state greatly affects the safe operation of the transmission system. Partial discharge (PD) characteristics of oil-pressboard insulation under combined AC-DC voltage are the foundation for analyzing the insulation state of UHVDC converter transformers. The defect pattern recognition based on PD characteristics is an important part of the state monitoring of converter transformers. In this paper, PD characteristics are investigated with the established experimental platform of three defect models (needle-plate, surface discharge and air gap) under 1:1 combined AC-DC voltage. The different PD behaviors of three defect models are discussed and explained through simulation of electric field strength distribution and discharge mechanism. For the recognition of defect types when multiple types of sources coexist, the Random Forests algorithm is used for recognition. In order to reduce the computational layer and the loss of information caused by the extraction of traditional features, the preprocessed single PD pulses and phase information are chosen to be the features for learning and test. Zero-padding method is discussed for normalizing the features. Based on the experimental data, Random Forests and Least Squares Support Vector Machine are compared in the performance of computing time, recognition accuracy and adaptability. It is proved that Random Forests is more suitable for big data analysis.

21 January 2025 in Thin-Walled Structures
Verified
Journal Article
Closed access
YJYunfei Jia
Yunfei Jia
XLXun Luo
Xun Luo
SJShengchang Ji
Shengchang Ji
DZDehua Zhao
Dehua Zhao
ZQZicheng Qiu
Zicheng Qiu
SLSimeng Li
Simeng Li

1 November 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
SLSimeng Li
Simeng Li
QLQingquan Li
Qingquan Li
DHDongxin He
Dongxin He
HLHongshun Liu
Hongshun Liu
PWPeijin Wang
Peijin Wang

26 April 2023 in IEEE Access
Verified
Journal Article
Open access
FQFeng Qin
Feng Qin
WCWei Chen
Wei Chen
XWXutong Wang
Xutong Wang
XNXin Nie
Xin Nie
SLSimeng Li
Simeng Li
Zinc oxide arresters, a major type of overvoltage protection equipment in power systems, can suppress transient lightning overvoltage, operation overvoltage, and other types of power surges. However, the response characteristics and protection effects under nanosecond pulses, such as those in a high-altitude electromagnetic pulse conduction region, remain unclear. Therefore, the surge protection performance of arresters should be properly understood, and high-performance arresters should be developed. In this study, critical parameters, including overshoot peak voltage, residual voltage, response time, and voltammetry characteristics of a representative 10 kV ZnO arrester under nanosecond pulses, were obtained using a double exponential pulse current injection source. The overshoot peak voltage of this arrester under a nanosecond pulse is 2.19 times of lightning impulse residual voltage, and the residual voltage ratio under a nanosecond pulse is 4.31. The average response time is approximately 45 ns, and the response time is independent of the nanosecond pulse amplitude. Furthermore, an electromagnetic transient model of this type of lightning arrester is established based on the CIGRE guidelines, as well as a method to determine the key parameters. The model can simultaneously account for the response characteristics of the small current region and the conduction region of the arrester, which properly agrees with the experimental results.