A reliable method of measuring diaphragmatic function at the bedside is still lacking. Widely used two-dimensional (2D) ultrasonographic measurements, such as diaphragm excursion, diaphragm thickness, and fractional thickening (FT) have failed to show clear correlations with diaphragmatic function. A reason for this is that 2D ultrasonographic measurements, like FT, are merely able to measure the deformation of muscular diaphragmatic tissue in the transverse direction, while longitudinal measurements in the direction of contracting muscle fibres are not possible. Speckle tracking ultrasonography, which is widely used in cardiac imaging, overcomes this disadvantage and allows observations of movement in the direction of the contracting muscle fibres, approximating muscle deformation and the deformation velocity. Several studies have evaluated speckle tracking as a promising method to assess diaphragm contractility in healthy subjects. This technical note demonstrates the feasibility of speckle tracking ultrasonography of the diaphragm in a group of 20 patients after an aortocoronary bypass graft procedure. The results presented herein suggest that speckle tracking ultrasonography is able to depict alterations in diaphragmatic function after surgery better than 2D ultrasonographic measurements.
The development of biomedical soft- or hardware frequently includes testing in animals. However, large efforts have been made to reduce the number of animal experiments, according to the 3Rs principle. Simultaneously, a significant number of surplus animals are euthanized without scientific necessity. The primary aim of this study was to establish a post-mortem rat perfusion model using extracorporeal membrane oxygenation (ECMO) in surplus rat cadavers and generate first post vivo results concerning the oxygenation performance of a recently developed ECMO membrane oxygenator. Four rats were euthanized and connected post-mortem to a venous–arterial ECMO circulation for up to eight hours. Angiographic perfusion proofs, blood gas analyses and blood oxygenation calculations were performed. The mean preparation time for the ECMO system was 791 ± 29 s and sufficient organ perfusion could be maintained for 463 ± 26 min, proofed via angiographic imaging and a mean femoral arterial pressure of 43 ± 17 mmHg. A stable partial oxygen pressure, a 73% rise in arterial oxygen concentration and an exponentially increasing oxygen extraction ratio up to 4.75 times were shown. Considering the 3Rs, the established post-mortal ECMO perfusion rat model using surplus animals represents a promising alternative to models using live animals. Given the preserved organ perfusion, its use could be conceivable for various biomedical device testing.