15 August 2007 in Nuclear Fusion
High-pressure noble gas jet injection is a mitigation technique which potentially satisfies the requirements of fast response time and reliability, without degrading subsequent discharges. Previously reported gas jet experiments on DIII-D showed good success at reducing deleterious disruption effects. In this paper, results of recent gas jet disruption mitigation experiments on Alcator C-Mod and DIII-D are reported. Jointly, these experiments have greatly improved the understanding of gas jet dynamics and the processes involved in mitigating disruption effects. In both machines, the sequence of events following gas injection is observed to be quite similar: the jet neutrals stop near the plasma edge, the edge temperature collapses and large MHD modes are quickly destabilized, mixing the hot plasma core with the edge impurity ions and radiating away the plasma thermal energy. High radiated power fractions are achieved, thus reducing the conducted heat loads to the chamber walls and divertor. A significant (2 × or more) reduction in halo current is also observed. Runaway electron generation is small or absent. These similar results in two quite different tokamaks are encouraging for the applicability of this disruption mitigation technique to ITER.
9 April 2009 in Plasma Physics and Controlled Fusion
1 March 2010 in Physics of Plasmas
Frequency-resolved nonlinear internal and kinetic energy transfer rates have been measured in the Controlled Shear Decorrelation Experiment (CSDX) linear plasma device using a recently developed technique [Xu et al., Phys. Plasmas16, 042312 (2009)]. The results clearly show a net kinetic energy transfer into the zonal flow frequency region, consistent with previous time-domain observations of turbulence-drivenshear flows [Tynan et al., Plasma Phys. Controlled Fusion48, S51 (2006)]. The experimentally measureddispersion relation has been used to map the frequency-resolved energy transfer rates into the wave number domain, which shows that the shear flow drive comes from midrange ( k θ ρ S > 0.3 ) drift fluctuations, and the strongest flow drive comes from k θ ρ S ≈ 1 fluctuations. Linear growth rates have been inferred from a linearized Hasegawa–Wakatani model [Hasegawa et al., Phys. Fluids22, 2122 (1979)], which indicates that the m = 0 mode is linearly stable and the m = 1 – 10 modes (corresponding to k θ ρ S > 0.3 ) are linearly unstable for the n = 1 and n = 2 radial eigenmodes. This is consistent with our energy transfermeasurements.
29 October 2009 in Plasma Physics and Controlled Fusion
15 June 2009 in Journal of Nuclear Materials
24 October 2017 in Physica Scripta
Unipolar arcing was an important mechanism of metal surface erosion during the recently conducted Metal Rings Campaign in DIII-D when two toroidally continuous tile rings with 5 cm wide W-coated TZM inserts were installed in graphite tiles in the lower divertor, one on the floor and one on the shelf. Most of the arc damage occurred on the shelf ring. The total amount of W removed by arcing from the affected ~4% of the shelf ring area was estimated ~0.8 × 1021 at., about half of the total amount of W eroded and redeposited outside the inserts (1.8 ± 0.9)×1021 at. The rings were exposed for a total of ~480 discharges, an equivalent of plasma time on W surfaces (with MA) ~103 s. Arcing was monitored in situ with WI (400.9 nm) filtered camera and photomultipliers and showed that: (i) arcing only occurred during ELMs and disruptions, (ii) arcing rate was much lower on the floor than on the shelf ring, and (iii) arcing had a low cut off power flux density about 2 MW m−2. About half of arc tracks had large pitch angle and probably were produced during disruptions. Such tracks were only found on the shelf. Moderate toroidal variation of the arc track density and W erosion with nearly n = 1 pattern has been measured.