Polyvinyl chloride (PVC), owing to its excellent electrical properties and low cost, is widely applied in the inner insulation and outer sheath of cables. To achieve early fault warning based on characteristic gases, this study integrates experimental testing with molecular simulations to systematically reveal the decomposition and gas generation characteristics of different PVC layers under electrical and thermal stresses. The results indicate that inner-layer PVC under electrical stress predominantly generates small-molecule olefins and halogenated hydrocarbons, while outer-layer PVC during thermal decomposition mainly produces hydrogen chloride, alkanes, and fragments of plasticizers. The surrounding atmosphere significantly regulates the gas generation pathways: air promotes the formation of CO2 and H2O, whereas electrical discharges accelerate the release of unsaturated hydrocarbons such as acetylene. By employing TG-FTIR, ReaxFF molecular dynamics, and DFT spectral calculations, a normalized infrared spectral library covering typical products was established and combined with the non-negative least squares method to realize quantitative deconvolution of mixed gases. Ultimately, a diagnostic system was constructed based on the concentration ratios of characteristic gases, which can effectively distinguish the failure modes of inner and outer PVC layers as well as different stress types. This provides a feasible approach for early detection of cable faults and supports intelligent maintenance strategies.
Due to their compact structure and low laying cost, three-core power cables are widely used for power distribution networks. The three-phases of such cables are distributed symmetrically with a 120° shift to each other. Phase current is an important parameter to reflect the operation state of the power system and three-core cable. Three-core symmetrical power cables use a common shield, leading to magnetic field cancelation outside the cable during steady operation. Thus, traditional magnetic-based current transformers cannot measure the phase current on three-core cable non-invasively. In order to measure the phase current more conveniently, a phase current measurement method for three-core cables based on a magnetic sensor is proposed in this paper. Nonlinear equations of a phase current and the magnetic field of a measuring point are constructed. The calculated magnetic field distribution of the three-core cable is verified using a finite element simulation. The effectiveness of the measurement method is further validated through experiments. This proposed method is able to conveniently detect the phase current of three-core power cables, which can help cable maintenance.
High-voltage cables are the main arteries of urban power supply. Cable accessories are connecting components between different sections of cables or between cables and other electrical equipment. The stress in the cold shrink tube of cable accessories is a key parameter to ensure the stable operation of the power system. This paper attempts to explore a method for measuring the stress in the cold shrink tube of high-voltage cable accessories based on ultrasonic longitudinal wave attenuation. Firstly, a pulse ultrasonic longitudinal wave testing system based on FPGA is designed, where the ultrasonic sensor operates in a single-transmit, single-receive mode with a frequency of 3 MHz, a repetition frequency of 50 Hz, and a data acquisition and transmission frequency of 40 MHz. Then, through experiments and theoretical calculations, the transmission and attenuation characteristics of ultrasonic longitudinal waves in multi-layer elastic media are studied, revealing an exponential relationship between ultrasonic wave attenuation and the thickness of the cold shrink tube. Finally, by establishing a theoretical model of the radial stress of the cold shrink tube, using the thickness of the cold shrink tube as an intermediate variable, an effective measurement of the stress of the cold shrink tube was achieved.
The direct current (DC) cable serves as the link for energy output in photovoltaic (PV) systems. Its degradation can cause arcs, which easily lead to fire accidents. Locating arc faults, however, is challenging. To cope with it, this paper proposes an arc location method based on time reversal. The method has been tried to locate system fault. However, its application in the arc fault location of photovoltaic systems is seldom discussed and needs further research. For this purpose, the voltage waveforms of an arc fault collected at one of the cable ends is reversed. This transformation derives a symmetrical arc fault signal. Afterwards, the reversed signal is injected back into the cable to trace the fault location, which is a symmetrical process of the arc fault signal travelling from its origin to the detection point. Utilizing the energy-focusing characteristics of time reversal, the position with the highest energy in the derived waveform corresponds to the actual fault location. To verify the proposed method, a DC arc fault test is performed to obtain the wave characteristics. The Paukert arc model is chosen based on the tested result. A PV system containing a DC cable with an arc fault is simulated with Simulink with the affecting factors, i.e., grounded resistance, cable length, fault location and sampling frequency. The simulated results demonstrate that the localization error is within 5% in the worst case.
A growing number of fires and explosions in energy storage plants have been triggered by the thermal runaway of lithium-ion batteries. Owing to the complex physicochemical properties of these batteries, their fire safety issues remain unresolved and constitute a major obstacle to the large-scale deployment of energy storage systems. Compared with conventional extinguishing media, liquid nitrogen (LN2) offers a dual suppression mechanism, i.e., rapid endothermic vaporization and oxygen displacement by inert nitrogen gas, making it highly suitable for lithium-ion battery fire control. However, the key operational parameters governing its suppression efficiency remain unclear, leading to excessive or insufficient LN2 use in practice. This study established a dedicated experimental platform and designed 10 experimental conditions, each repeated three times, to investigate the propagation of thermal runaway between adjacent batteries and to quantify the suppression performance of LN2 under varying nozzle diameters and injection strategies. Results demonstrate that under identical injection pressures, larger nozzle diameters significantly outperform smaller ones in cooling and suppression efficiency. The optimal nozzle diameter was found to be 14 mm, achieving a cooling efficiency of 40%. Furthermore, intermittent LN2 injection of equal total mass outperformed continuous injection, with a 45 s intermittent duration achieving a cooling efficiency of 63%, 23% higher than continuous injection. These findings provide quantitative guidance for the design of LN2-based suppression systems in large-scale lithium-ion battery energy storage modules.